# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 81
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       1.490000     1.490000     2.110000     2.110000     1.320000     1.320000     2.500000     2.500000 
# z_pos      56.000000    56.000000    57.000000    57.000000    55.000000    55.000000    58.000000    58.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       321          322          323          324          325          326          327          328      
#
# lambda for peak transmission
#          608.0850000  575.0030000  608.0850000  629.0790000  608.0850000  578.0330000  608.0850000  611.0540000 
# peak transmission
#            0.9768100    0.9764930    0.9757280    0.9784850    0.9768190    0.9755070    0.9773000    0.9744630 
# lambda blue with 1/2 of peak transmission
#          550.5725160  550.6665925  550.5601007  550.6142966  550.5309797  551.1096206  550.5226372  552.2500302 
# lambda red  with 1/2 of peak transmission
#          697.6958128  698.9814931  697.5558569  696.2821895  698.2013005  700.8031536  697.6963387  697.3480767 
# half width                              
#          147.1232969  148.3149006  146.9957562  145.6678929  147.6703208  149.6935330  147.1737015  145.0980465 
# central wavelength                      
#          624.1341644  624.8240428  624.0579788  623.4482431  624.3661401  625.9563871  624.1094880  624.7990534 
# central wavelength calculated as SAGEM (mean frequency)
#          615.4640476  616.0226410  615.4018311  614.9394634  615.6346754  617.0068203  615.4330863  616.3749677 
# lambda blue with 80% of peak transmission
#          553.1382053  553.2530502  553.1262335  553.1635353  553.1237491  553.6407614  553.1182981  554.8990077 
# lambda red  with 80% of peak transmission
#          695.2065768  696.0778115  695.0125095  693.3692662  695.4965020  698.4144454  695.1909467  694.5902956 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.9628497    0.9647574    0.9656223    0.9664525    0.9639691    0.9619281    0.9626194    0.9648548 
# ATB calculated from points above 50%
#            0.9542297    0.9486832    0.9530020    0.9509123    0.9461155    0.9619281    0.9541392    0.9552046 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 623.448243 at column =  5, at id = 324 
# maxCWL      = 625.956387 at column =  7, at id = 326 
# difference =    2.5081440 
# minBW       = 145.098047 at column =  9, at id = 328 
# maxBW       = 149.693533 at column =  7, at id = 326 
# difference =    4.5954865 
# minATB80    = 0.961928 at column =  7, at id = 326 
# maxATB80    = 0.966452 at column =  5, at id = 324 
# difference =    0.0045244 
# minBlueEdge = 550.522637 at column =  8, at id = 327 
# maxBlueEdge = 552.250030 at column =  9, at id = 328 
# difference =    1.7273930 
# minRedEdge  = 696.282190 at column =  5, at id = 324 
# maxRedEdge  = 700.803154 at column =  7, at id = 326 
# difference =    4.5209641 
# minABR      = 9.999900 at column =  2, at id = 321 
# maxABR      = 9.999900 at column =  2, at id = 321 
# difference =    0.0000000 
  499.928     0.000001     0.000001     0.000001     0.000000     0.000000     0.000002    -0.000000    -0.000000 
  502.914     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001 
  505.899     0.000002     0.000003     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001 
  508.941     0.000002     0.000003     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000 
  511.925     0.000003     0.000003     0.000008     0.000001     0.000002     0.000003     0.000001     0.000002 
  514.909     0.000011     0.000018     0.000016     0.000009     0.000016     0.000017     0.000011     0.000002 
  517.949     0.000018     0.000023     0.000023     0.000020     0.000021     0.000020     0.000023     0.000017 
  520.933     0.000031     0.000032     0.000029     0.000024     0.000028     0.000031     0.000030     0.000020 
  523.972     0.000063     0.000062     0.000063     0.000064     0.000060     0.000054     0.000063     0.000041 
  526.954     0.000139     0.000139     0.000138     0.000133     0.000143     0.000122     0.000138     0.000086 
  529.936     0.000297     0.000293     0.000288     0.000276     0.000303     0.000271     0.000290     0.000186 
  532.974     0.000563     0.000578     0.000545     0.000524     0.000582     0.000579     0.000558     0.000337 
  535.955     0.001396     0.001325     0.001371     0.001367     0.001408     0.001174     0.001372     0.000813 
  538.992     0.004329     0.003994     0.004319     0.004551     0.004320     0.003400     0.004291     0.002241 
  541.972     0.015131     0.014850     0.014976     0.014017     0.015516     0.012832     0.015102     0.008053 
  544.952     0.046534     0.045601     0.046654     0.044963     0.047903     0.041786     0.047299     0.022767 
  547.987     0.169549     0.159414     0.172302     0.172517     0.172383     0.136290     0.174351     0.080376 
  550.966     0.536931     0.524989     0.537643     0.531641     0.542450     0.471148     0.543606     0.312454 
  554.000     0.878457     0.864871     0.878846     0.878384     0.878514     0.821941     0.879434     0.725431 
  556.978     0.936455     0.939788     0.934079     0.936883     0.937377     0.941662     0.933259     0.904770 
  560.012     0.963130     0.957387     0.962068     0.964790     0.960879     0.943277     0.960269     0.955153 
  562.988     0.964689     0.966273     0.964603     0.960209     0.965436     0.966496     0.963963     0.954203 
  566.021     0.970122     0.969889     0.970020     0.970061     0.969556     0.970653     0.969625     0.958674 
  568.997     0.972035     0.970097     0.971273     0.972030     0.970972     0.967167     0.970780     0.967986 
  572.028     0.974635     0.974063     0.975078     0.974579     0.974590     0.969929     0.975095     0.967697 
  575.003     0.975065     0.976493     0.975367     0.972758     0.975658     0.974611     0.976325     0.968560 
  578.033     0.972632     0.975401     0.972158     0.968615     0.973647     0.975507     0.973358     0.965664 
  581.007     0.972172     0.974126     0.971801     0.971790     0.972715     0.973974     0.972635     0.964462 
  584.037     0.970120     0.974149     0.969465     0.965198     0.971321     0.974917     0.970786     0.964082 
  587.010     0.972122     0.973921     0.971359     0.974057     0.972371     0.973078     0.972376     0.963727 
  590.038     0.970902     0.972378     0.970335     0.972080     0.971562     0.971729     0.970674     0.970029 
  593.010     0.971434     0.971650     0.970673     0.973114     0.971958     0.969588     0.970631     0.969225 
  596.037     0.968089     0.968331     0.967273     0.969843     0.968120     0.969012     0.966662     0.966565 
  599.064     0.971112     0.970321     0.970251     0.972299     0.971308     0.968236     0.970510     0.967807 
  602.034     0.965987     0.966537     0.964510     0.966234     0.966210     0.969282     0.964928     0.966206 
  605.060     0.969743     0.966895     0.969478     0.973454     0.970021     0.963999     0.970355     0.964144 
  608.085     0.976810     0.974821     0.975728     0.978302     0.976819     0.973706     0.977300     0.974150 
  611.054     0.974460     0.973418     0.973480     0.976518     0.974616     0.973823     0.975148     0.974463 
  614.078     0.972865     0.973061     0.972498     0.975499     0.974169     0.972164     0.973622     0.971915 
  617.046     0.973384     0.973281     0.973239     0.974653     0.974447     0.973549     0.973965     0.971130 
  620.069     0.972980     0.973604     0.972252     0.973244     0.973759     0.974275     0.973103     0.970012 
  623.091     0.969791     0.970720     0.969746     0.972000     0.970895     0.971708     0.970270     0.967973 
  626.057     0.971902     0.971981     0.971660     0.974760     0.972199     0.971347     0.972738     0.967935 
  629.079     0.975023     0.975145     0.975606     0.978485     0.975376     0.973680     0.976372     0.973297 
  632.100     0.973571     0.974825     0.974340     0.976555     0.974657     0.974900     0.974909     0.974403 
  635.120     0.971759     0.972361     0.971757     0.974489     0.973000     0.973442     0.973096     0.971098 
  638.084     0.972927     0.973459     0.972026     0.974387     0.972711     0.973739     0.973082     0.971400 
  641.103     0.969684     0.970799     0.968234     0.971728     0.969573     0.972424     0.968925     0.969530 
  644.121     0.969551     0.968739     0.968214     0.973251     0.969024     0.968171     0.968296     0.966928 
  647.084     0.973838     0.974265     0.972666     0.975742     0.974128     0.972038     0.973257     0.972101 
  650.101     0.971716     0.971469     0.969577     0.973168     0.971872     0.973562     0.970573     0.971765 
  653.118     0.968685     0.968471     0.966437     0.969421     0.969520     0.969460     0.967980     0.969254 
  656.134     0.962941     0.963482     0.960522     0.963205     0.963698     0.967811     0.961945     0.962821 
  659.150     0.966433     0.962295     0.964376     0.970091     0.965263     0.961180     0.965519     0.963160 
  662.109     0.972640     0.972780     0.970975     0.970566     0.972718     0.970899     0.972685     0.969117 
  665.124     0.966374     0.967949     0.965093     0.967520     0.967086     0.973218     0.966307     0.962491 
  668.138     0.970745     0.970661     0.969825     0.971540     0.970657     0.970308     0.970783     0.966800 
  671.151     0.964640     0.967128     0.962460     0.963442     0.964922     0.970057     0.963478     0.965151 
  674.164     0.958747     0.960649     0.957207     0.961434     0.959474     0.960011     0.958094     0.957188 
  677.120     0.963531     0.962401     0.961530     0.967942     0.963274     0.959825     0.963139     0.961564 
  680.132     0.967504     0.965270     0.965838     0.970535     0.966683     0.962846     0.966699     0.967555 
  683.143     0.969912     0.967851     0.969280     0.973981     0.969708     0.964239     0.969988     0.968889 
  686.153     0.972088     0.973011     0.970331     0.971863     0.972529     0.971503     0.972093     0.970529 
  689.163     0.967957     0.969993     0.965819     0.964135     0.969557     0.972985     0.968103     0.965208 
  692.172     0.932053     0.953888     0.925674     0.879305     0.941383     0.968510     0.930670     0.926208 
  695.181     0.784459     0.859169     0.771976     0.636736     0.815617     0.927685     0.783004     0.743752 
  698.189     0.430345     0.597634     0.412119     0.233844     0.489918     0.808026     0.430997     0.387690 
  701.196     0.095279     0.182579     0.089108     0.041046     0.121148     0.439624     0.096058     0.085377 
  704.203     0.020917     0.034624     0.019626     0.011990     0.025038     0.095134     0.020691     0.016823 
  707.209     0.009411     0.013387     0.008755     0.005542     0.010745     0.025218     0.009161     0.007227 
  710.214     0.003206     0.005331     0.002953     0.001588     0.003850     0.011241     0.003123     0.002712 
  713.219     0.000834     0.001355     0.000771     0.000469     0.000991     0.003336     0.000811     0.000688 
  716.223     0.000365     0.000501     0.000342     0.000233     0.000406     0.000948     0.000353     0.000277 
  719.227     0.000193     0.000265     0.000181     0.000121     0.000218     0.000447     0.000189     0.000150 
  722.230     0.000079     0.000119     0.000073     0.000048     0.000089     0.000216     0.000078     0.000067 
  725.232     0.000035     0.000054     0.000038     0.000032     0.000043     0.000089     0.000035     0.000031 
  728.233     0.000038     0.000039     0.000025     0.000025     0.000033     0.000045     0.000034     0.000029 
  731.234     0.000018     0.000033     0.000023     0.000019     0.000024     0.000035     0.000025     0.000021 
  734.235     0.000003     0.000005     0.000003     0.000001     0.000002     0.000025     0.000000     0.000001 
  737.234     0.000004     0.000004     0.000001     0.000002     0.000003     0.000002     0.000002     0.000002 
  740.233     0.000002     0.000002     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001 