# number of points on sci filter + aux + bad z = 13
# number of points on sci filter               = 13
# number of positions in lambda                = 301
# noof scans  1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000    17.670000   -17.670000   -17.670000    17.670000    35.340000   -35.340000   -35.340000    35.340000    53.010000   -53.010000   -53.010000    53.010000 
# y_pos       0.000000    17.670000    17.670000   -17.670000   -17.670000    35.340000    35.340000   -35.340000   -35.340000    53.010000    53.010000   -53.010000   -53.010000 
# angle       1.780000     1.320000     1.840000     2.230000     1.840000     0.870000     2.000000     2.690000     2.000000     0.410000     2.230000     3.140000     2.230000 
# z_pos      44.000000    43.000000    45.000000    47.000000    45.000000    42.000000    46.000000    48.000000    46.000000    41.000000    47.000000    49.000000    47.000000 
# r_pos       0.000000    24.990000    24.990000    24.990000    24.990000    49.980000    49.980000    49.980000    49.980000    74.970000    74.970000    74.970000    74.970000 
# phi         0.000000     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14      
# pos_id       302          303          304          305          306          307          308          309          310          311          312          313          314      
#
# lambda for peak transmission
#          573.0380000  573.0380000  573.0380000  567.0320000  567.0320000  567.0320000  576.0130000  567.0320000  567.0320000  567.0320000  567.0320000  567.0320000  567.0320000 
# peak transmission
#            0.7618969    0.7609218    0.7602637    0.7595227    0.7614084    0.7597150    0.7575297    0.7595798    0.7602302    0.7591146    0.7567341    0.7585416    0.7615124 
# lambda blue with 1/2 of peak transmission
#          550.5984629  550.6513997  550.6431836  550.3956418  550.4155674  550.7859147  550.7781783  550.4882917  550.5296742  551.1179378  551.1547545  550.7696100  550.8186450 
# lambda red  with 1/2 of peak transmission
#          697.2596816  698.3189977  698.1208402  696.1969040  696.3299821  699.8847341  699.4633724  695.4842080  695.8480871  701.2533004  700.7564532  695.3991319  695.7091555 
# half width                              
#          146.6612187  147.6675979  147.4776566  145.8012622  145.9144147  149.0988193  148.6851941  144.9959163  145.3184129  150.1353626  149.6016987  144.6295219  144.8905105 
# central wavelength                      
#          623.9290723  624.4851987  624.3820119  623.2962729  623.3727747  625.3353244  625.1207754  622.9862498  623.1888806  626.1856191  625.9556038  623.0843709  623.2639002 
# central wavelength calculated as SAGEM (mean frequency)
#          615.3104992  615.7557206  615.6735374  614.7698269  614.8341373  616.4479095  616.2795691  614.5495405  614.7173555  617.1864396  617.0170033  614.6915675  614.8432055 
# lambda blue with 80% of peak transmission
#          553.2335589  553.2633650  553.2541665  552.9953135  553.0243898  553.4435262  553.4314380  553.1586231  553.1827750  553.9018303  553.9423290  553.5333350  553.5428594 
# lambda red  with 80% of peak transmission
#          693.5305570  694.5282719  694.3410247  692.2711454  692.3927960  696.2360281  695.5804483  691.6800456  692.0130013  697.5092520  696.9354563  691.5261720  691.8645234 
# lambda blue with 0.0001 of peak transmission
#          525.5036265  525.3511796  525.3530137  525.2784833  525.1624596  525.5083181  525.7401223  525.3944751  525.3249524  525.5009694  525.9260068  525.6465075  525.5802916 
# lambda red  with 0.0001 of peak transmission
#          721.1032585  722.3469950  722.2179178  719.7291994  719.8870076  723.9293216  723.0397360  719.1133340  719.4581131  725.6933023  725.0775433  718.9693709  719.3416096 
# ATB calculated from points above 80%
#            0.7302058    0.7301045    0.7291406    0.7303617    0.7308279    0.7257935    0.7263231    0.7298782    0.7308260    0.7268475    0.7243800    0.7294178    0.7311889 
# ATB calculated from points above 50%
#            0.7210271    0.7223321    0.7211910    0.7164871    0.7173074    0.7159426    0.7128403    0.7222421    0.7234280    0.7184523    0.7152772    0.7208832    0.7229620 
# ABR calculated from points below and above 0.0001
#           -0.0000003   -0.0000016    0.0000252    0.0000144    0.0000221    0.0000286    0.0000016    0.0000222    0.0000106    0.0000223    0.0000061    0.0000101    0.0000066 
# minCWL      = 622.986250 at column =  9, at id = 309 
# maxCWL      = 626.185619 at column = 11, at id = 311 
# difference =    3.1993693 
# minBW       = 144.629522 at column = 13, at id = 313 
# maxBW       = 150.135363 at column = 11, at id = 311 
# difference =    5.5058407 
# minATB80    = 0.724380 at column = 12, at id = 312 
# maxATB80    = 0.731189 at column = 14, at id = 314 
# difference =    0.0068089 
# minBlueEdge = 550.395642 at column =  5, at id = 305 
# maxBlueEdge = 551.154754 at column = 12, at id = 312 
# difference =    0.7591126 
# minRedEdge  = 695.399132 at column = 13, at id = 313 
# maxRedEdge  = 701.253300 at column = 11, at id = 311 
# difference =    5.8541685 
# minABR      = -0.000002 at column =  3, at id = 303 
# maxABR      = 0.000029 at column =  7, at id = 307 
# difference =    0.0000302 
  299.645    -0.000119    -0.000045     0.000432     0.000426     0.000263     0.000527    -0.000008     0.000451     0.000234     0.000388     0.000067     0.000161     0.000159 
  302.654    -0.000102    -0.000071     0.000016     0.000015     0.000012     0.000068    -0.000103     0.000008     0.000019    -0.000024    -0.000054    -0.000015    -0.000043 
  305.662     0.000034    -0.000028     0.000016    -0.000037     0.000036     0.000027    -0.000038    -0.000011    -0.000027    -0.000012     0.000009    -0.000008     0.000021 
  308.671    -0.000006    -0.000052     0.000021    -0.000021     0.000035     0.000013    -0.000006     0.000018    -0.000014    -0.000028    -0.000014    -0.000010    -0.000035 
  311.679    -0.000016    -0.000049     0.000009    -0.000020     0.000028     0.000006    -0.000013     0.000006    -0.000011     0.000005    -0.000011    -0.000024    -0.000016 
  314.687     0.000002    -0.000006    -0.000006    -0.000023     0.000016     0.000002    -0.000010     0.000008    -0.000009     0.000017     0.000013    -0.000013    -0.000003 
  317.694    -0.000008    -0.000008     0.000006    -0.000019     0.000019     0.000007    -0.000022     0.000009    -0.000008     0.000011    -0.000005    -0.000003    -0.000016 
  320.702    -0.000007    -0.000009     0.000021    -0.000012     0.000023     0.000015     0.000004     0.000003    -0.000016     0.000009    -0.000010    -0.000005    -0.000005 
  323.709     0.000001    -0.000004     0.000014    -0.000002     0.000014     0.000011    -0.000014     0.000001    -0.000011     0.000004    -0.000007    -0.000000    -0.000004 
  326.716    -0.000001    -0.000001     0.000004    -0.000010     0.000008     0.000008    -0.000009     0.000013    -0.000005     0.000009    -0.000006    -0.000008    -0.000005 
  329.665     0.000010    -0.000001    -0.000001    -0.000013     0.000007    -0.000002     0.000009     0.000005    -0.000005     0.000005    -0.000002    -0.000004    -0.000011 
  332.672    -0.000002     0.000003     0.000008    -0.000008    -0.000002     0.000007    -0.000001     0.000002    -0.000006     0.000007    -0.000005     0.000013    -0.000008 
  335.678    -0.000000     0.000002     0.000007    -0.000008     0.000002     0.000001     0.000004     0.000010    -0.000002     0.000009    -0.000001     0.000008    -0.000010 
  338.683     0.000005     0.000007     0.000006    -0.000002    -0.000003     0.000001    -0.000000     0.000002    -0.000003     0.000002     0.000001    -0.000000    -0.000007 
  341.689    -0.000002    -0.000003     0.000005    -0.000004    -0.000002     0.000003    -0.000000    -0.000001    -0.000006     0.000003    -0.000005     0.000003    -0.000004 
  344.694     0.000001    -0.000006     0.000010    -0.000003     0.000001     0.000003     0.000004    -0.000002    -0.000004    -0.000001    -0.000006     0.000003    -0.000002 
  347.699    -0.000005    -0.000005     0.000003    -0.000004     0.000004     0.000005     0.000002     0.000001    -0.000005     0.000003     0.000001     0.000007    -0.000000 
  350.703     0.000001    -0.000003     0.000001    -0.000007     0.000005     0.000007     0.000002     0.000005    -0.000003    -0.000001     0.000003     0.000003    -0.000001 
  353.707     0.000002     0.000000     0.000002    -0.000001     0.000007     0.000001     0.000001     0.000002     0.000000     0.000001     0.000005     0.000005    -0.000003 
  356.711    -0.000003     0.000001     0.000003    -0.000001     0.000003    -0.000000     0.000001     0.000001    -0.000001     0.000003     0.000003    -0.000001    -0.000004 
  359.715    -0.000001    -0.000004     0.000002    -0.000004     0.000001     0.000009     0.000003     0.000001    -0.000001     0.000006     0.000003     0.000001    -0.000002 
  362.718    -0.000001    -0.000003     0.000001    -0.000003    -0.000001     0.000002     0.000003     0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000003 
  365.721     0.000001    -0.000003     0.000003    -0.000003     0.000001     0.000000     0.000003    -0.000001     0.000001     0.000003     0.000001    -0.000001    -0.000000 
  368.724     0.000001     0.000000     0.000002     0.000001     0.000001    -0.000000    -0.000001     0.000000    -0.000002    -0.000001    -0.000001    -0.000001     0.000001 
  371.726    -0.000000    -0.000003    -0.000001    -0.000002    -0.000001     0.000001     0.000001    -0.000000    -0.000002     0.000002    -0.000001     0.000001    -0.000001 
  374.728     0.000001    -0.000002     0.000003    -0.000002    -0.000001     0.000002     0.000001     0.000001    -0.000001     0.000005    -0.000001     0.000000    -0.000002 
  377.730    -0.000001    -0.000002     0.000001     0.000001     0.000002     0.000003     0.000000    -0.000001     0.000001     0.000005    -0.000001     0.000001     0.000001 
  380.788    -0.000001    -0.000001     0.000001     0.000000     0.000001     0.000003     0.000000     0.000001    -0.000001     0.000005    -0.000001     0.000001    -0.000000 
  383.789     0.000000    -0.000001     0.000001    -0.000000     0.000001     0.000004     0.000001    -0.000000    -0.000001     0.000001    -0.000001     0.000001    -0.000001 
  386.789     0.000001    -0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000002    -0.000003    -0.000000    -0.000001 
  389.790    -0.000001    -0.000002     0.000002     0.000002    -0.000000    -0.000000    -0.000000    -0.000002     0.000001     0.000000     0.000000     0.000001    -0.000002 
  392.790    -0.000002    -0.000002     0.000001     0.000000    -0.000000     0.000002    -0.000001    -0.000002     0.000000     0.000000     0.000000    -0.000000    -0.000002 
  395.790    -0.000002    -0.000002    -0.000000     0.000001     0.000001    -0.000001    -0.000000    -0.000000     0.000001     0.000002    -0.000000    -0.000001    -0.000002 
  398.789    -0.000002    -0.000000    -0.000001     0.000001     0.000001    -0.000001    -0.000000    -0.000000     0.000001     0.000001    -0.000001     0.000001    -0.000002 
  401.788    -0.000002    -0.000002     0.000002    -0.000001     0.000002     0.000000    -0.000001    -0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000001 
  404.787    -0.000002    -0.000001     0.000001    -0.000001     0.000000    -0.000001     0.000001     0.000001     0.000001     0.000002     0.000000     0.000002    -0.000002 
  407.785    -0.000001    -0.000001     0.000001    -0.000002     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001    -0.000002 
  410.783    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000002 
  413.781    -0.000001    -0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000001     0.000002    -0.000001 
  416.834    -0.000000    -0.000002     0.000003     0.000001     0.000002     0.000001     0.000000    -0.000001     0.000000     0.000002    -0.000001     0.000002    -0.000000 
  419.831    -0.000000    -0.000001     0.000002     0.000002     0.000001     0.000002     0.000001    -0.000000     0.000001     0.000002     0.000001     0.000002     0.000002 
  422.828     0.000001     0.000000     0.000001     0.000002     0.000001     0.000002     0.000000     0.000001     0.000000     0.000003     0.000002     0.000002     0.000002 
  425.824    -0.000000     0.000000     0.000001     0.000002     0.000001     0.000002     0.000001     0.000000     0.000000     0.000003     0.000002     0.000002     0.000000 
  428.820     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000002     0.000001     0.000001     0.000001 
  431.815     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002     0.000001     0.000000    -0.000000     0.000002     0.000001     0.000001     0.000002 
  434.810     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001    -0.000000    -0.000001     0.000002     0.000001     0.000001     0.000000 
  437.862     0.000001     0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000000    -0.000001     0.000002     0.000001     0.000000    -0.000000 
  440.856     0.000001    -0.000000     0.000001     0.000002    -0.000000     0.000002     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000 
  443.850     0.000000     0.000000     0.000001     0.000001     0.000000     0.000002    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000 
  446.844    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000002     0.000000     0.000000    -0.000000 
  449.837     0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000001    -0.000002     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000 
  452.830     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000 
  455.878    -0.000001     0.000000     0.000001     0.000001     0.000000     0.000002    -0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000 
  458.870    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000 
  461.862     0.000000    -0.000001     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000001 
  464.853     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000 
  467.901     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000001 
  470.891     0.000001     0.000000     0.000000     0.000001     0.000001     0.000002    -0.000001     0.000001     0.000000     0.000001    -0.000000     0.000001    -0.000001 
  473.881     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000001     0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000 
  476.871     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001 
  479.916     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002    -0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001 
  482.905     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  485.894     0.000001     0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000000     0.000001     0.000000     0.000002     0.000000 
  488.882     0.000000     0.000000     0.000001     0.000000     0.000001     0.000002    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000001    -0.000000 
  491.925    -0.000001     0.000001     0.000001     0.000001     0.000000     0.000002     0.000000     0.000002     0.000001     0.000002     0.000001     0.000000    -0.000000 
  494.913     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001 
  497.899     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001     0.000002     0.000001     0.000002     0.000002 
  500.942     0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000002     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000002 
  503.928     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000001 
  506.913     0.000002     0.000001     0.000002     0.000001     0.000002     0.000002     0.000000     0.000002     0.000002     0.000002     0.000001     0.000002     0.000001 
  509.954     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002     0.000002     0.000002 
  512.939     0.000002     0.000007     0.000007     0.000002     0.000008     0.000002     0.000001     0.000007     0.000002     0.000003     0.000002     0.000002     0.000007 
  515.923     0.000014     0.000011     0.000015     0.000013     0.000008     0.000015     0.000015     0.000015     0.000009     0.000015     0.000014     0.000003     0.000009 
  518.963     0.000018     0.000021     0.000018     0.000019     0.000019     0.000027     0.000020     0.000017     0.000016     0.000022     0.000018     0.000015     0.000016 
  521.946     0.000032     0.000027     0.000033     0.000033     0.000035     0.000037     0.000029     0.000030     0.000026     0.000030     0.000029     0.000029     0.000029 
  524.929     0.000061     0.000065     0.000065     0.000067     0.000070     0.000060     0.000054     0.000065     0.000066     0.000062     0.000052     0.000060     0.000061 
  527.967     0.000143     0.000143     0.000142     0.000145     0.000147     0.000145     0.000135     0.000134     0.000142     0.000135     0.000123     0.000128     0.000130 
  530.949     0.000288     0.000303     0.000297     0.000284     0.000290     0.000310     0.000287     0.000260     0.000269     0.000292     0.000268     0.000246     0.000251 
  533.987     0.000570     0.000581     0.000574     0.000592     0.000598     0.000609     0.000568     0.000570     0.000573     0.000612     0.000557     0.000522     0.000522 
  536.968     0.001518     0.001524     0.001506     0.001596     0.001597     0.001449     0.001408     0.001534     0.001520     0.001287     0.001223     0.001400     0.001374 
  539.948     0.005388     0.005107     0.005115     0.005879     0.005876     0.004600     0.004566     0.005706     0.005643     0.003926     0.003791     0.005051     0.005042 
  542.984     0.016771     0.017205     0.017011     0.017169     0.017200     0.017008     0.016454     0.016248     0.016079     0.014954     0.014438     0.014649     0.014272 
  545.964     0.054500     0.054775     0.054211     0.057721     0.057626     0.053774     0.052170     0.055011     0.054213     0.048514     0.047100     0.049891     0.047753 
  548.999     0.213072     0.205267     0.205918     0.231267     0.229796     0.188327     0.189650     0.221132     0.217039     0.158435     0.157153     0.198656     0.192572 
  551.977     0.525637     0.521006     0.521460     0.547895     0.547045     0.507524     0.506192     0.538385     0.534312     0.469205     0.462742     0.502433     0.500551 
  555.012     0.728236     0.727996     0.727611     0.725895     0.726939     0.714989     0.714513     0.716327     0.720253     0.686935     0.683025     0.706023     0.711157 
  557.989     0.744373     0.741655     0.741500     0.747782     0.748249     0.740924     0.735586     0.746860     0.748904     0.740848     0.735385     0.745605     0.748674 
  561.023     0.759845     0.758932     0.759276     0.757002     0.758336     0.753726     0.750966     0.753210     0.755977     0.742808     0.741927     0.753851     0.757462 
  563.999     0.758244     0.759724     0.759224     0.755219     0.756754     0.759373     0.756175     0.752326     0.753621     0.757078     0.756023     0.752183     0.755009 
  567.032     0.760600     0.760120     0.759486     0.759523     0.761408     0.759715     0.756500     0.759580     0.760230     0.759115     0.756734     0.758542     0.761512 
  570.007     0.760365     0.758642     0.757756     0.758750     0.760110     0.755497     0.753536     0.758415     0.758404     0.752888     0.749658     0.757644     0.759552 
  573.038     0.761897     0.760922     0.760264     0.759440     0.761334     0.758426     0.757297     0.759207     0.758946     0.755104     0.754428     0.758469     0.760338 
  576.013     0.759738     0.759978     0.759079     0.756870     0.758548     0.758048     0.757530     0.755340     0.755983     0.757082     0.756665     0.755635     0.756792 
  579.043     0.756111     0.756962     0.755640     0.752572     0.754653     0.755557     0.755351     0.751845     0.751451     0.757613     0.756303     0.752049     0.752960 
  582.017     0.756453     0.756023     0.755491     0.753033     0.754537     0.754106     0.753309     0.751838     0.753067     0.755537     0.754278     0.752158     0.753761 
  585.046     0.752300     0.753104     0.752370     0.747661     0.749064     0.752727     0.751757     0.746722     0.747689     0.755430     0.753627     0.747133     0.748695 
  588.019     0.754564     0.753426     0.752905     0.751955     0.753145     0.751287     0.750073     0.752158     0.753264     0.752620     0.751479     0.752177     0.754150 
  591.047     0.751462     0.750419     0.749637     0.748521     0.750046     0.748218     0.745967     0.748918     0.750455     0.749870     0.746805     0.748702     0.750580 
  594.019     0.750274     0.749846     0.748831     0.747674     0.749083     0.747367     0.745785     0.747925     0.749247     0.747700     0.746092     0.747741     0.749717 
  597.046     0.746931     0.745916     0.744985     0.745605     0.746678     0.743457     0.741850     0.746151     0.747053     0.744708     0.742295     0.745949     0.747825 
  600.073     0.747501     0.748189     0.747726     0.744608     0.745820     0.745100     0.743661     0.744786     0.745729     0.744521     0.743770     0.744291     0.746970 
  603.043     0.741093     0.741416     0.740596     0.739309     0.740317     0.739550     0.737383     0.740205     0.741047     0.742643     0.740051     0.739917     0.741744 
  606.068     0.747205     0.745484     0.744734     0.747113     0.747098     0.740283     0.739934     0.748035     0.747713     0.739115     0.738359     0.747296     0.748765 
  609.038     0.747787     0.747347     0.745935     0.746336     0.746392     0.743707     0.743598     0.747110     0.747461     0.745446     0.743762     0.747608     0.748486 
  612.062     0.745215     0.744806     0.742880     0.743735     0.743269     0.740949     0.740288     0.743980     0.744915     0.744052     0.740845     0.745025     0.745283 
  615.086     0.744177     0.743970     0.742317     0.742728     0.742119     0.739836     0.738949     0.742375     0.743099     0.742418     0.739963     0.743155     0.743535 
  618.053     0.743160     0.743460     0.741424     0.741377     0.740356     0.740010     0.738825     0.740274     0.741327     0.742130     0.740464     0.740747     0.741852 
  621.076     0.740229     0.741018     0.738701     0.738006     0.737443     0.739255     0.736915     0.737505     0.738594     0.741424     0.739497     0.737497     0.738665 
  624.099     0.738111     0.737407     0.735435     0.735884     0.735608     0.735667     0.732898     0.735236     0.736149     0.736879     0.734720     0.735393     0.736051 
  627.064     0.738056     0.737131     0.735621     0.737515     0.737391     0.734952     0.732341     0.736793     0.737929     0.735151     0.733218     0.737260     0.737678 
  630.086     0.738468     0.737417     0.736035     0.737568     0.737235     0.735431     0.733017     0.736799     0.737571     0.735900     0.733398     0.737195     0.738177 
  633.106     0.735166     0.733917     0.732898     0.733582     0.732932     0.733023     0.730144     0.732749     0.733805     0.734040     0.731591     0.732546     0.733729 
  636.071     0.732976     0.731471     0.730274     0.730976     0.730898     0.730549     0.727991     0.730621     0.731552     0.731063     0.729192     0.730068     0.731496 
  639.090     0.730168     0.729148     0.728446     0.728217     0.728101     0.728662     0.726152     0.727712     0.729058     0.729975     0.727718     0.727431     0.729023 
  642.109     0.725241     0.724556     0.723588     0.723700     0.724132     0.724402     0.721613     0.723779     0.724948     0.726894     0.723938     0.724060     0.725447 
  645.128     0.725986     0.723607     0.722891     0.725311     0.725366     0.721025     0.719305     0.725359     0.726599     0.720464     0.718961     0.725200     0.726559 
  648.090     0.725538     0.724795     0.723997     0.723380     0.724057     0.723160     0.721246     0.724000     0.724621     0.722229     0.721913     0.723927     0.725440 
  651.107     0.721515     0.720778     0.719796     0.719200     0.720165     0.718824     0.717031     0.720671     0.720922     0.721894     0.719761     0.720360     0.721945 
  654.123     0.718082     0.717529     0.716284     0.714104     0.715060     0.715347     0.713664     0.714658     0.715557     0.718328     0.715060     0.714084     0.716346 
  657.139     0.712189     0.710985     0.709956     0.710158     0.710313     0.710195     0.707590     0.711103     0.711506     0.714428     0.710939     0.710849     0.712130 
  660.099     0.715718     0.712754     0.712101     0.715175     0.714858     0.708083     0.706791     0.715857     0.715747     0.710532     0.705106     0.714871     0.716391 
  663.114     0.714303     0.715054     0.714107     0.710148     0.710664     0.714269     0.713091     0.709866     0.710514     0.714966     0.713139     0.709800     0.711287 
  666.129     0.710876     0.709407     0.708961     0.709254     0.708810     0.708772     0.707471     0.709873     0.709736     0.713052     0.709918     0.709062     0.710144 
  669.142     0.710828     0.710288     0.710013     0.707832     0.707657     0.708478     0.707834     0.707448     0.708062     0.709596     0.708217     0.707549     0.708487 
  672.155     0.701653     0.701036     0.700292     0.698331     0.697657     0.701171     0.699122     0.697596     0.698682     0.706794     0.702183     0.698224     0.699266 
  675.168     0.696871     0.694263     0.693937     0.694870     0.693755     0.692668     0.690383     0.695367     0.696327     0.694726     0.691629     0.696242     0.696366 
  678.124     0.695180     0.693322     0.692358     0.695110     0.694425     0.690495     0.688709     0.696206     0.696278     0.690711     0.689093     0.696151     0.697014 
  681.136     0.692226     0.691290     0.689892     0.692537     0.692663     0.689027     0.686666     0.693789     0.693862     0.690155     0.686455     0.693286     0.694647 
  684.146     0.691693     0.690219     0.689528     0.690851     0.690903     0.687037     0.685015     0.691577     0.691848     0.685690     0.683455     0.690328     0.692379 
  687.157     0.686822     0.687561     0.686633     0.684148     0.684409     0.687040     0.684704     0.684215     0.685184     0.686260     0.685548     0.682777     0.685548 
  690.166     0.678248     0.680703     0.680747     0.668432     0.669662     0.680912     0.678529     0.662507     0.667545     0.683578     0.681387     0.657736     0.666175 
  693.175     0.626395     0.651207     0.647738     0.581508     0.587862     0.666663     0.660448     0.553513     0.570839     0.676593     0.672121     0.545128     0.565259 
  696.183     0.483609     0.556808     0.545770     0.381017     0.394223     0.610603     0.592391     0.327219     0.356219     0.642425     0.630905     0.320816     0.346257 
  699.191     0.196798     0.308469     0.288659     0.109290     0.117563     0.450022     0.404985     0.080045     0.094144     0.562742     0.528897     0.084905     0.090640 
  702.198     0.035690     0.067402     0.060904     0.019193     0.020657     0.145895     0.115511     0.014566     0.016881     0.295644     0.239752     0.015205     0.016128 
  705.205     0.010179     0.015510     0.014351     0.006964     0.007376     0.028700     0.022824     0.005765     0.006412     0.063059     0.047441     0.005601     0.006081 
  708.211     0.004556     0.006873     0.006393     0.002872     0.003085     0.011015     0.009122     0.002256     0.002605     0.018656     0.014561     0.002235     0.002452 
  711.216     0.001314     0.002250     0.002053     0.000747     0.000801     0.004274     0.003366     0.000573     0.000668     0.008254     0.006238     0.000589     0.000633 
  714.220     0.000392     0.000602     0.000549     0.000258     0.000271     0.001095     0.000859     0.000212     0.000237     0.002236     0.001692     0.000212     0.000226 
  717.224     0.000190     0.000268     0.000246     0.000139     0.000145     0.000408     0.000335     0.000118     0.000130     0.000686     0.000532     0.000112     0.000124 
  720.228     0.000092     0.000133     0.000124     0.000063     0.000067     0.000205     0.000171     0.000051     0.000057     0.000335     0.000259     0.000050     0.000056 
  723.230     0.000039     0.000052     0.000052     0.000025     0.000029     0.000088     0.000069     0.000025     0.000023     0.000154     0.000117     0.000022     0.000024 
  726.232     0.000016     0.000027     0.000025     0.000015     0.000021     0.000036     0.000029     0.000015     0.000020     0.000059     0.000050     0.000016     0.000016 
  729.234     0.000014     0.000022     0.000022     0.000013     0.000016     0.000031     0.000019     0.000013     0.000016     0.000041     0.000032     0.000012     0.000018 
  732.234     0.000010     0.000015     0.000015     0.000001     0.000003     0.000025     0.000017     0.000001     0.000002     0.000035     0.000022     0.000001     0.000002 
  735.235     0.000000     0.000001     0.000002     0.000002     0.000002     0.000004     0.000002     0.000001     0.000002     0.000019     0.000014     0.000001     0.000002 
  738.234     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000002     0.000001    -0.000000     0.000001 
  741.233    -0.000001     0.000001     0.000001     0.000000     0.000001     0.000002     0.000001     0.000000     0.000001     0.000002     0.000001    -0.000000     0.000001 
  744.231    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000002     0.000000     0.000000     0.000001     0.000002     0.000001     0.000000     0.000000 
  747.228     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000002     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000001 
  750.225    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000002     0.000001     0.000000     0.000001     0.000002     0.000001     0.000000    -0.000001 
  753.221     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000001    -0.000000    -0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000001 
  756.272     0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000001    -0.000001    -0.000001     0.000000     0.000001     0.000000     0.000000    -0.000001 
  759.267     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000000    -0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000001 
  762.261     0.000000    -0.000001     0.000001     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000001    -0.000000    -0.000000    -0.000000 
  765.254    -0.000001    -0.000000     0.000001     0.000000    -0.000001    -0.000001    -0.000001    -0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000001 
  768.247     0.000000    -0.000000     0.000000    -0.000001    -0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000001    -0.000001    -0.000001     0.000000 
  771.294    -0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000000    -0.000001    -0.000001     0.000001     0.000001    -0.000000    -0.000000    -0.000001 
  774.286    -0.000001    -0.000000     0.000001    -0.000001    -0.000000     0.000000    -0.000001    -0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000 
  777.277    -0.000001     0.000000     0.000001    -0.000001    -0.000000    -0.000001    -0.000000    -0.000001     0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  780.266    -0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000001    -0.000000     0.000001    -0.000000    -0.000001    -0.000000    -0.000000 
  783.311    -0.000001    -0.000001     0.000001    -0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000 
  786.300    -0.000001     0.000000     0.000001     0.000000     0.000001     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000 
  789.288    -0.000000    -0.000001     0.000001    -0.000000     0.000001    -0.000001    -0.000001    -0.000000    -0.000001     0.000000    -0.000001    -0.000000    -0.000001 
  792.275    -0.000000    -0.000001     0.000001    -0.000001    -0.000001    -0.000000    -0.000001    -0.000001     0.000000     0.000001     0.000000    -0.000001    -0.000000 
  795.316    -0.000000     0.000000     0.000002     0.000000     0.000000    -0.000001    -0.000001    -0.000000    -0.000000     0.000001    -0.000001    -0.000001     0.000001 
  798.302    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000001     0.000001     0.000000    -0.000000    -0.000000 
  801.287    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000 
  804.327     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000 
  807.310    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000 
  810.348    -0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000 
  813.331     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  816.312    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  819.348     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  822.328     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000 
  825.362     0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000 
  828.341     0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001 
  831.374     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001 
  834.351     0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000 
  837.382     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000 
  840.357     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000 
  843.387     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000 
  846.361     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000 
  849.389     0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000 
  852.362     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000000    -0.000000 
  855.389    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  858.359    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000000 
  861.385     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000000 
  864.409     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  867.378    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
  870.400     0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
  873.422     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000001    -0.000000    -0.000000 
  876.389     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000001 
  879.409    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001 
  882.428    -0.000000     0.000000     0.000001    -0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
  885.447     0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000 
  888.410    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000001 
  891.427     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  894.444     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000 
  897.459     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000000 
  900.419     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000 
  903.433     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  906.446     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  909.458    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
  912.469    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
  915.480    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
  918.489    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
  921.443    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000 
  924.451    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  927.458    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  930.465    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
  933.470    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  936.475    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  939.478    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
  942.481     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
  945.483     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000 
  948.484    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
  951.484    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000 
  954.538    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  957.537    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000 
  960.534     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  963.531     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  966.526     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
  969.521     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
  972.515     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  975.563    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
  978.555    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  981.546     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  984.537    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  987.580    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  990.569    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  993.556     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  996.543     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  999.583     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000 
 1002.568     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1005.552    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1008.589    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1011.571     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1014.606     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1017.587     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1020.620     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1023.598     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1026.629     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1029.606     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1032.635     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1035.610    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1038.637    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1041.610     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1044.635     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
 1047.660     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
 1050.629     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1053.652    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1056.620    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1059.640     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1062.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1065.678     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
 1068.642     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1071.658     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1074.674     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
 1077.688     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1080.702     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1083.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1086.672     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
 1089.682     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1092.691     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1095.699     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1098.707     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1101.713     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1104.718     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1107.722     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1110.725     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1113.727     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1116.728     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1119.728     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1122.726     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1125.724     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1128.720     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1131.770     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1134.764     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1137.757     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1140.749     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1143.741     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1146.784     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1149.773     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1152.761     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1155.801     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1158.786     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1161.771     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1164.807     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1167.790     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1170.771     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1173.804     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1176.783     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1179.814     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1182.790     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1185.819     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1188.793     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1191.820     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1194.845     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1197.815     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1200.838     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 