# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 104
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       1.490000     2.110000     2.110000     1.490000     1.320000     2.500000     2.500000     1.320000 
# z_pos      56.000000    57.000000    57.000000    56.000000    55.000000    58.000000    58.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       221          222          223          224          225          226          227          228      
#
# lambda for peak transmission
#          696.1830000  696.1830000  696.1830000  696.1830000  696.1830000  696.1830000  696.1830000  696.1830000 
# peak transmission
#            0.6483097    0.6473148    0.6450427    0.6458504    0.6548549    0.6506609    0.6495321    0.6519623 
# lambda blue with 1/2 of peak transmission
#          689.5842109  689.6169546  689.6942706  689.6938031  689.4261908  689.5022044  689.6870960  689.5793417 
# lambda red  with 1/2 of peak transmission
#          843.7237093  843.6033697  843.7164908  843.8830831  844.0128739  843.8530705  844.0698317  844.1994636 
# half width                              
#          154.1394984  153.9864151  154.0222202  154.1892800  154.5866832  154.3508661  154.3827356  154.6201220 
# central wavelength                      
#          766.6539601  766.6101621  766.7053807  766.7884431  766.7195324  766.6776374  766.8784638  766.8894027 
# central wavelength calculated as SAGEM (mean frequency)
#          758.9063366  758.8774783  758.9700612  759.0371741  758.9275558  758.9089910  759.1086443  759.0957814 
# lambda blue with 80% of peak transmission
#          692.6784514  692.7147282  692.7887558  692.7642779  692.5124373  692.5975490  692.7537248  692.6453929 
# lambda red  with 80% of peak transmission
#          778.4992467  778.7352324  779.4969832  779.3102557  778.6197585  779.0690565  779.8278269  779.2274866 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.5927135    0.5919263    0.5910948    0.5916059    0.5985430    0.5955909    0.5956482    0.5969880 
# ATB calculated from points above 50%
#            0.5244904    0.5236854    0.5230822    0.5236792    0.5305218    0.5277060    0.5277600    0.5291121 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 766.610162 at column =  3, at id = 222 
# maxCWL      = 766.889403 at column =  9, at id = 228 
# difference =    0.2792405 
# minBW       = 153.986415 at column =  3, at id = 222 
# maxBW       = 154.620122 at column =  9, at id = 228 
# difference =    0.6337068 
# minATB80    = 0.591095 at column =  4, at id = 223 
# maxATB80    = 0.598543 at column =  6, at id = 225 
# difference =    0.0074482 
# minBlueEdge = 689.426191 at column =  6, at id = 225 
# maxBlueEdge = 689.694271 at column =  4, at id = 223 
# difference =    0.2680798 
# minRedEdge  = 843.603370 at column =  3, at id = 222 
# maxRedEdge  = 844.199464 at column =  9, at id = 228 
# difference =    0.5960939 
# minABR      = 9.999900 at column =  2, at id = 221 
# maxABR      = 9.999900 at column =  2, at id = 221 
# difference =    0.0000000 
  600.073    -0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  603.043    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
  606.068    -0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000001    -0.000000 
  609.038     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000 
  612.062     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000000 
  615.086     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001 
  618.053     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000 
  621.076     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000000 
  624.099     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000000 
  627.064     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000 
  630.086     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001 
  633.106     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  636.071     0.000002     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  639.090     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  642.109     0.000001     0.000001     0.000001     0.000005     0.000001     0.000001     0.000002     0.000001 
  645.128     0.000002     0.000002     0.000001     0.000004     0.000001     0.000002     0.000002     0.000004 
  648.090     0.000012     0.000011     0.000010     0.000009     0.000011     0.000011     0.000011     0.000013 
  651.107     0.000016     0.000013     0.000016     0.000018     0.000018     0.000015     0.000014     0.000016 
  654.123     0.000025     0.000021     0.000020     0.000021     0.000026     0.000023     0.000021     0.000025 
  657.139     0.000060     0.000060     0.000058     0.000060     0.000065     0.000058     0.000058     0.000061 
  660.099     0.000096     0.000091     0.000088     0.000093     0.000101     0.000090     0.000090     0.000096 
  663.114     0.000150     0.000141     0.000141     0.000145     0.000157     0.000144     0.000139     0.000150 
  666.129     0.000301     0.000286     0.000282     0.000289     0.000316     0.000291     0.000280     0.000302 
  669.142     0.000579     0.000561     0.000546     0.000558     0.000606     0.000567     0.000538     0.000579 
  672.155     0.001303     0.001263     0.001229     0.001252     0.001372     0.001284     0.001216     0.001298 
  675.168     0.002670     0.002595     0.002518     0.002569     0.002832     0.002660     0.002528     0.002692 
  678.124     0.007188     0.007093     0.006792     0.006812     0.007620     0.007311     0.006698     0.007053 
  681.136     0.021244     0.020696     0.020159     0.020439     0.022607     0.021307     0.020145     0.021522 
  684.146     0.040989     0.040237     0.039189     0.039564     0.043866     0.041919     0.039327     0.041873 
  687.157     0.132770     0.133062     0.127453     0.125271     0.142730     0.140028     0.126166     0.131244 
  690.166     0.370029     0.366197     0.358789     0.359716     0.387643     0.377779     0.362358     0.373144 
  693.175     0.548020     0.545239     0.539191     0.541492     0.562354     0.554429     0.545229     0.553274 
  696.183     0.648310     0.647315     0.645043     0.645850     0.654855     0.650661     0.649532     0.651962 
  699.191     0.646016     0.644565     0.643518     0.645091     0.651291     0.646957     0.647417     0.650254 
  702.198     0.647071     0.645604     0.644465     0.645810     0.652725     0.648138     0.648716     0.651108 
  705.205     0.643525     0.642268     0.641169     0.642225     0.648716     0.644973     0.645686     0.647347 
  708.211     0.643502     0.642664     0.641769     0.642201     0.649431     0.646505     0.646972     0.648089 
  711.216     0.645221     0.644197     0.644003     0.643284     0.650342     0.648393     0.649403     0.648656 
  714.220     0.643526     0.642491     0.642427     0.642355     0.648617     0.646656     0.647586     0.646805 
  717.224     0.635685     0.635283     0.634884     0.635307     0.641262     0.638948     0.639615     0.639777 
  720.228     0.630727     0.629785     0.628831     0.629206     0.636056     0.633315     0.633446     0.634553 
  723.230     0.626308     0.625425     0.624925     0.624716     0.631650     0.629190     0.629453     0.630162 
  726.232     0.615178     0.613711     0.613821     0.613909     0.620585     0.618017     0.618344     0.619555 
  729.234     0.603926     0.603208     0.602463     0.602530     0.609740     0.606400     0.606160     0.608195 
  732.234     0.603778     0.603054     0.602221     0.601862     0.608810     0.605917     0.605652     0.607459 
  735.235     0.599175     0.599036     0.598389     0.598066     0.604634     0.601788     0.602482     0.604468 
  738.234     0.592315     0.591853     0.590841     0.591255     0.597784     0.594877     0.595048     0.597001 
  741.233     0.591039     0.590709     0.589814     0.590107     0.596672     0.594344     0.594336     0.595646 
  744.231     0.584454     0.583937     0.583462     0.584062     0.590047     0.587776     0.588498     0.589390 
  747.228     0.575712     0.575314     0.574759     0.575106     0.581099     0.578376     0.579119     0.580044 
  750.225     0.574267     0.573880     0.573175     0.573430     0.579572     0.577271     0.577354     0.578104 
  753.221     0.570342     0.569705     0.569167     0.569854     0.575533     0.573277     0.573642     0.574717 
  756.272     0.558933     0.558251     0.557735     0.558884     0.564519     0.561558     0.562247     0.563491 
  759.267     0.549335     0.548631     0.548146     0.549217     0.554781     0.551718     0.552007     0.553555 
  762.261     0.545379     0.544875     0.544419     0.545189     0.551169     0.548653     0.548517     0.549778 
  765.254     0.543512     0.542913     0.542475     0.543054     0.549359     0.546768     0.547079     0.547785 
  768.247     0.539543     0.539028     0.538471     0.539173     0.545291     0.543051     0.543616     0.544084 
  771.294     0.534075     0.533762     0.533395     0.533808     0.539712     0.537634     0.538505     0.538763 
  774.286     0.528241     0.527864     0.527758     0.528019     0.533951     0.531652     0.532467     0.532613 
  777.277     0.521392     0.521120     0.520851     0.521326     0.526989     0.524714     0.525497     0.525823 
  780.266     0.514682     0.514422     0.514366     0.514497     0.520077     0.517733     0.518617     0.519305 
  783.311     0.508134     0.507784     0.507795     0.507994     0.513554     0.511016     0.512492     0.512289 
  786.300     0.501805     0.501506     0.501210     0.501519     0.507138     0.505180     0.505910     0.506150 
  789.288     0.494810     0.494380     0.494133     0.494464     0.500288     0.498149     0.499185     0.499451 
  792.275     0.486229     0.485823     0.485360     0.485849     0.491466     0.489803     0.490349     0.491053 
  795.316     0.476559     0.476343     0.476099     0.476520     0.482208     0.480202     0.480651     0.481645 
  798.302     0.469358     0.468932     0.468718     0.469210     0.474496     0.472464     0.472604     0.473883 
  801.287     0.464629     0.464188     0.463589     0.464221     0.469658     0.467379     0.467498     0.468678 
  804.327     0.461017     0.460797     0.460212     0.460773     0.466115     0.464118     0.464008     0.465015 
  807.310     0.456526     0.456139     0.455938     0.456373     0.461876     0.459903     0.460188     0.461051 
  810.348     0.449100     0.448796     0.448494     0.448983     0.454625     0.452654     0.453209     0.453826 
  813.331     0.441818     0.441457     0.441141     0.441484     0.447046     0.445183     0.445498     0.446245 
  816.312     0.435767     0.435399     0.435054     0.435607     0.441254     0.439189     0.439385     0.440100 
  819.348     0.427635     0.426960     0.426932     0.427528     0.432881     0.430695     0.431220     0.431962 
  822.328     0.417541     0.416860     0.416735     0.417633     0.423103     0.420694     0.421024     0.422231 
  825.362     0.411130     0.410498     0.410562     0.410879     0.416525     0.414330     0.414382     0.415394 
  828.341     0.408083     0.407493     0.407540     0.407715     0.413461     0.411737     0.411530     0.412643 
  831.374     0.400860     0.400158     0.400503     0.400952     0.406631     0.404280     0.405217     0.405899 
  834.351     0.390301     0.389400     0.389606     0.390279     0.395907     0.393603     0.394469     0.395299 
  837.382     0.384762     0.384007     0.384000     0.384185     0.389890     0.388007     0.388144     0.388903 
  840.357     0.379165     0.378023     0.378537     0.379413     0.385740     0.383532     0.384423     0.385415 
  843.387     0.336500     0.331873     0.334848     0.340555     0.349361     0.342552     0.348938     0.353149 
  846.361     0.227460     0.218954     0.223586     0.234867     0.245137     0.232662     0.243659     0.253701 
  849.389     0.109531     0.102997     0.106615     0.115464     0.122536     0.112364     0.120469     0.129992 
  852.362     0.041715     0.038776     0.040363     0.044474     0.047790     0.042841     0.046127     0.051278 
  855.389     0.015362     0.014221     0.014760     0.016313     0.017612     0.015633     0.016846     0.018851 
  858.359     0.006073     0.005616     0.005798     0.006390     0.006888     0.006123     0.006563     0.007327 
  861.385     0.002631     0.002437     0.002501     0.002747     0.002950     0.002630     0.002791     0.003112 
  864.409     0.001276     0.001183     0.001213     0.001323     0.001423     0.001269     0.001336     0.001487 
  867.378     0.000661     0.000615     0.000628     0.000686     0.000737     0.000657     0.000684     0.000767 
  870.400     0.000362     0.000337     0.000342     0.000373     0.000403     0.000360     0.000375     0.000420 
  873.422     0.000203     0.000190     0.000195     0.000212     0.000227     0.000203     0.000211     0.000235 
  876.389     0.000120     0.000113     0.000115     0.000125     0.000135     0.000120     0.000124     0.000134 
  879.409     0.000073     0.000069     0.000068     0.000075     0.000081     0.000071     0.000075     0.000081 
  882.428     0.000047     0.000040     0.000042     0.000046     0.000050     0.000045     0.000047     0.000050 
  885.447     0.000029     0.000025     0.000026     0.000030     0.000033     0.000029     0.000028     0.000033 
  888.410     0.000018     0.000017     0.000015     0.000020     0.000021     0.000017     0.000017     0.000022 
  891.427     0.000011     0.000009     0.000010     0.000014     0.000012     0.000011     0.000012     0.000013 
  894.444     0.000008     0.000007     0.000008     0.000009     0.000009     0.000007     0.000008     0.000010 
  897.459     0.000006     0.000005     0.000001     0.000006     0.000006     0.000007     0.000004     0.000007 
  900.419     0.000003     0.000000     0.000002     0.000003     0.000003     0.000001     0.000004     0.000006 
  903.433     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002 
  906.446     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000 
  909.458     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001 