# number of points on sci filter + aux + bad z = 13
# number of points on sci filter               = 13
# number of positions in lambda                = 301
# noof scans  1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000    17.670000   -17.670000   -17.670000    17.670000    35.340000   -35.340000   -35.340000    35.340000    53.010000   -53.010000   -53.010000    53.010000 
# y_pos       0.000000    17.670000    17.670000   -17.670000   -17.670000    35.340000    35.340000   -35.340000   -35.340000    53.010000    53.010000   -53.010000   -53.010000 
# angle       1.780000     1.840000     2.230000     1.840000     1.320000     2.000000     2.690000     2.000000     0.870000     2.230000     3.140000     2.230000     0.410000 
# z_pos      44.000000    45.000000    47.000000    45.000000    43.000000    46.000000    48.000000    46.000000    42.000000    47.000000    49.000000    47.000000    41.000000 
# r_pos       0.000000    24.990000    24.990000    24.990000    24.990000    49.980000    49.980000    49.980000    49.980000    74.970000    74.970000    74.970000    74.970000 
# phi         0.000000     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14      
# pos_id       202          203          204          205          206          207          208          209          210          211          212          213          214      
#
# lambda for peak transmission
#          714.2200000  714.2200000  714.2200000  714.2200000  714.2200000  753.2210000  714.2200000  714.2200000  714.2200000  771.2940000  771.2940000  774.2860000  714.2200000 
# peak transmission
#            0.9599410    0.9638260    0.9618430    0.9626120    0.9628240    0.9670050    0.9672080    0.9673310    0.9683350    0.9764170    0.9777500    0.9765390    0.9794760 
# lambda blue with 1/2 of peak transmission
#          689.7750503  689.8010703  689.8850322  689.9169359  689.8008036  689.7840971  689.9385830  690.0729867  689.8021659  688.6950141  688.7975143  689.1180342  688.6410395 
# lambda red  with 1/2 of peak transmission
#          847.0548797  847.3002931  847.2668722  847.3813437  847.4780877  847.7659719  847.7303281  848.0649104  848.2115188  846.8422950  846.8042114  847.4777792  847.5836130 
# half width                              
#          157.2798294  157.4992229  157.3818400  157.4644078  157.6772841  157.9818748  157.7917451  157.9919237  158.4093529  158.1472809  158.0066971  158.3597450  158.9425735 
# central wavelength                      
#          768.4149650  768.5506817  768.5759522  768.6491398  768.6394457  768.7750345  768.8344555  769.0689486  769.0068423  767.7686545  767.8008628  768.2979067  768.1123262 
# central wavelength calculated as SAGEM (mean frequency)
#          760.3669226  760.4815960  760.5191546  760.5846542  760.5530385  760.6587873  760.7383580  760.9547710  760.8490726  759.6247422  759.6717640  760.1377228  759.8899801 
# lambda blue with 80% of peak transmission
#          693.0148204  693.0308065  693.1259536  693.1390368  693.0366878  693.0099528  693.1530045  693.2800538  693.0115748  691.8461835  692.0086172  692.3130126  691.7336091 
# lambda red  with 80% of peak transmission
#          843.9849873  844.1863307  844.1689911  844.2333602  844.3134979  844.6060959  844.5712782  844.8889520  845.0072023  843.8908461  843.8424301  844.3698691  844.4322073 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.9426918    0.9462836    0.9431168    0.9443709    0.9455885    0.9517235    0.9500293    0.9544759    0.9532758    0.9628336    0.9629212    0.9630004    0.9672892 
# ATB calculated from points above 50%
#            0.9273430    0.9313127    0.9279855    0.9293369    0.9309698    0.9376172    0.9355830    0.9367400    0.9399809    0.9490339    0.9488047    0.9495850    0.9551577 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 767.768655 at column = 11, at id = 211 
# maxCWL      = 769.068949 at column =  9, at id = 209 
# difference =    1.3002940 
# minBW       = 157.279829 at column =  2, at id = 202 
# maxBW       = 158.942574 at column = 14, at id = 214 
# difference =    1.6627441 
# minATB80    = 0.942692 at column =  2, at id = 202 
# maxATB80    = 0.967289 at column = 14, at id = 214 
# difference =    0.0245973 
# minBlueEdge = 688.641039 at column = 14, at id = 214 
# maxBlueEdge = 690.072987 at column =  9, at id = 209 
# difference =    1.4319472 
# minRedEdge  = 846.804211 at column = 12, at id = 212 
# maxRedEdge  = 848.211519 at column = 10, at id = 210 
# difference =    1.4073074 
# minABR      = 9.999900 at column =  2, at id = 202 
# maxABR      = 9.999900 at column =  2, at id = 202 
# difference =    0.0000000 
  299.645     0.000683     0.000246     0.000225     0.000117     0.000175     0.000423     0.000830    -0.000227     0.000165     0.000303    -0.000239     0.000731    -0.000231 
  302.654    -0.000013     0.000015    -0.000013     0.000081     0.000147     0.000139     0.000001    -0.000061    -0.000032     0.000007    -0.000212    -0.000028    -0.000086 
  305.662     0.000030    -0.000018    -0.000069    -0.000009     0.000024    -0.000006    -0.000012    -0.000019     0.000165     0.000052    -0.000056    -0.000026    -0.000006 
  308.671    -0.000030    -0.000004    -0.000058    -0.000033     0.000017     0.000014     0.000000    -0.000049     0.000034     0.000037    -0.000031    -0.000036     0.000022 
  311.679    -0.000023    -0.000038    -0.000011    -0.000012     0.000034     0.000018    -0.000028    -0.000024    -0.000052     0.000015     0.000003     0.000026     0.000017 
  314.687     0.000008    -0.000025     0.000003     0.000007     0.000005     0.000026    -0.000017     0.000043    -0.000024     0.000001    -0.000003    -0.000022    -0.000003 
  317.694    -0.000007    -0.000002    -0.000002     0.000034    -0.000010     0.000003     0.000019     0.000002    -0.000001     0.000024    -0.000016    -0.000014     0.000007 
  320.702    -0.000009    -0.000017    -0.000010     0.000036     0.000007     0.000022     0.000012    -0.000010    -0.000001     0.000016     0.000009    -0.000012    -0.000009 
  323.709    -0.000014    -0.000015    -0.000008    -0.000002     0.000010     0.000005     0.000017    -0.000008    -0.000008     0.000010    -0.000008    -0.000004     0.000002 
  326.716     0.000004    -0.000016    -0.000004     0.000009     0.000014     0.000013     0.000017    -0.000019    -0.000007    -0.000005    -0.000007    -0.000003     0.000007 
  329.665    -0.000001    -0.000021     0.000006     0.000016    -0.000000     0.000004     0.000012    -0.000014    -0.000013     0.000003     0.000003    -0.000003    -0.000006 
  332.672    -0.000007    -0.000010     0.000003     0.000012     0.000011    -0.000003     0.000009    -0.000025    -0.000023     0.000015     0.000007    -0.000000    -0.000005 
  335.678    -0.000012    -0.000003    -0.000001     0.000004     0.000006     0.000001     0.000012    -0.000014    -0.000008     0.000002    -0.000008     0.000003    -0.000005 
  338.683    -0.000015     0.000001    -0.000006     0.000002     0.000003    -0.000002    -0.000008    -0.000014    -0.000002    -0.000008    -0.000004     0.000005    -0.000012 
  341.689    -0.000008    -0.000005    -0.000004     0.000005     0.000015    -0.000005     0.000002    -0.000002    -0.000002    -0.000001    -0.000001    -0.000000    -0.000008 
  344.694    -0.000007    -0.000007    -0.000002     0.000002     0.000002    -0.000002    -0.000003    -0.000001    -0.000000    -0.000003    -0.000003     0.000005    -0.000006 
  347.699    -0.000001    -0.000005    -0.000007     0.000006    -0.000000    -0.000005    -0.000004    -0.000004    -0.000000     0.000001     0.000002    -0.000000    -0.000006 
  350.703    -0.000004    -0.000011    -0.000004     0.000005     0.000006     0.000002    -0.000006    -0.000001     0.000002     0.000005    -0.000001    -0.000004     0.000002 
  353.707    -0.000003    -0.000002     0.000001     0.000009     0.000008    -0.000001     0.000002    -0.000007    -0.000002     0.000002     0.000001    -0.000002     0.000001 
  356.711    -0.000003    -0.000006    -0.000002     0.000003     0.000012    -0.000000     0.000002    -0.000001     0.000002     0.000003     0.000003    -0.000005     0.000000 
  359.715    -0.000006    -0.000002    -0.000001     0.000005     0.000002    -0.000002     0.000002    -0.000000     0.000001     0.000001    -0.000001    -0.000002     0.000002 
  362.718    -0.000005    -0.000000    -0.000002     0.000006    -0.000000    -0.000003    -0.000004    -0.000003    -0.000000     0.000002    -0.000003    -0.000006     0.000005 
  365.721    -0.000006    -0.000002    -0.000005     0.000007     0.000003    -0.000000     0.000001    -0.000002    -0.000002    -0.000001    -0.000005    -0.000005     0.000004 
  368.724    -0.000005    -0.000002    -0.000002     0.000003    -0.000000     0.000001    -0.000003    -0.000001    -0.000001     0.000002    -0.000001    -0.000002    -0.000000 
  371.726    -0.000004    -0.000003    -0.000002     0.000002    -0.000001     0.000001     0.000001    -0.000001    -0.000001     0.000004     0.000000    -0.000000    -0.000002 
  374.728    -0.000004     0.000000    -0.000001     0.000000    -0.000001    -0.000004     0.000001    -0.000001     0.000001     0.000004     0.000004     0.000000    -0.000004 
  377.730    -0.000003    -0.000002    -0.000002     0.000001    -0.000002    -0.000002    -0.000001    -0.000001    -0.000001     0.000002     0.000001    -0.000001    -0.000002 
  380.788    -0.000002    -0.000001    -0.000001     0.000001    -0.000001    -0.000000     0.000001    -0.000002    -0.000002     0.000002    -0.000001    -0.000001     0.000002 
  383.789    -0.000001    -0.000001    -0.000000     0.000004     0.000002     0.000002     0.000001    -0.000001     0.000001     0.000001    -0.000002    -0.000001    -0.000000 
  386.789    -0.000003    -0.000002    -0.000001     0.000004     0.000001     0.000002     0.000001    -0.000001     0.000002     0.000000     0.000002    -0.000003     0.000001 
  389.790     0.000001     0.000001     0.000001     0.000003     0.000001     0.000002     0.000001    -0.000001     0.000000     0.000003     0.000003     0.000001     0.000002 
  392.790     0.000053     0.000049     0.000038     0.000046     0.000051     0.000021     0.000002     0.000002     0.000061     0.000004     0.000002     0.000001     0.000040 
  395.790     0.000084     0.000072     0.000041     0.000083     0.000113     0.000051     0.000021     0.000049     0.000102     0.000008     0.000004     0.000005     0.000043 
  398.789     0.000004     0.000002     0.000003     0.000001     0.000006     0.000001     0.000002    -0.000001     0.000003     0.000006     0.000004     0.000005     0.000003 
  401.788     0.000002     0.000002     0.000002     0.000004     0.000003     0.000002     0.000001     0.000001     0.000005     0.000002     0.000001    -0.000000     0.000004 
  404.787     0.000038     0.000032     0.000029     0.000038     0.000046     0.000017     0.000002     0.000016     0.000043     0.000003     0.000002     0.000001     0.000030 
  407.785     0.000027     0.000000     0.000010     0.000004     0.000022     0.000003     0.000008     0.000003     0.000028     0.000006     0.000002     0.000004     0.000001 
  410.783     0.000001    -0.000001     0.000004     0.000004     0.000006     0.000006     0.000004     0.000006     0.000003     0.000003     0.000001     0.000002     0.000006 
  413.781     0.000004     0.000002     0.000002     0.000003     0.000004     0.000003     0.000003     0.000003     0.000004     0.000002    -0.000001     0.000003     0.000003 
  416.834     0.000002     0.000001     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000001     0.000002     0.000000     0.000001     0.000002 
  419.831     0.000015     0.000003     0.000002     0.000029     0.000026     0.000003     0.000003     0.000001     0.000028     0.000004     0.000001     0.000002     0.000005 
  422.828     0.000016     0.000006     0.000005     0.000003     0.000027     0.000008     0.000003     0.000004     0.000011     0.000003     0.000002     0.000003     0.000006 
  425.824     0.000025     0.000027     0.000028     0.000028     0.000031     0.000008     0.000004     0.000013     0.000030     0.000003     0.000002     0.000002     0.000006 
  428.820     0.000000     0.000001    -0.000001    -0.000000     0.000004     0.000008     0.000004     0.000001    -0.000000     0.000004     0.000001     0.000003     0.000004 
  431.815     0.000002     0.000002     0.000001     0.000002     0.000002     0.000003     0.000003     0.000000     0.000002     0.000002     0.000000    -0.000000     0.000004 
  434.810     0.000003     0.000002     0.000001     0.000003     0.000002     0.000002     0.000002     0.000010     0.000004     0.000003     0.000001     0.000000     0.000003 
  437.862     0.000004     0.000004     0.000004     0.000005     0.000000     0.000004     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000010 
  440.856     0.000001     0.000001     0.000001     0.000002     0.000002     0.000003     0.000003     0.000002     0.000003     0.000002     0.000001     0.000001     0.000004 
  443.850     0.000002     0.000001     0.000001     0.000001     0.000002     0.000003     0.000002     0.000001     0.000002     0.000002     0.000001     0.000000     0.000003 
  446.844     0.000002     0.000002     0.000002     0.000003     0.000019     0.000005     0.000002     0.000002     0.000013     0.000003     0.000002     0.000002     0.000013 
  449.837     0.000002     0.000002     0.000004     0.000003     0.000001     0.000005     0.000002     0.000002    -0.000000     0.000003     0.000000     0.000002     0.000001 
  452.830     0.000000     0.000000     0.000000     0.000000     0.000002     0.000002     0.000001     0.000000     0.000001     0.000003    -0.000000     0.000000     0.000004 
  455.878     0.000000     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002    -0.000000     0.000002     0.000004 
  458.870     0.000000     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000002    -0.000000     0.000001     0.000003 
  461.862    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000003 
  464.853     0.000001     0.000001     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000002     0.000002     0.000001     0.000000     0.000004 
  467.901     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000002     0.000001     0.000003 
  470.891    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000002    -0.000000     0.000002 
  473.881     0.000000     0.000000     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000000     0.000003 
  476.871     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000001     0.000001     0.000003     0.000001     0.000001    -0.000000     0.000003 
  479.916    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000013 
  482.905     0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000002     0.000000     0.000000     0.000002 
  485.894     0.000001     0.000001    -0.000000     0.000001     0.000002     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000004 
  488.882    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000003 
  491.925     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000001    -0.000001     0.000001     0.000005 
  494.913    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000003    -0.000001     0.000000     0.000005 
  497.899    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000002    -0.000000    -0.000000     0.000005 
  500.942     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000002    -0.000001    -0.000001     0.000004 
  503.928    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000002    -0.000000     0.000000     0.000003 
  506.913    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000002     0.000001     0.000000     0.000021 
  509.954    -0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000004     0.000000     0.000001     0.000016 
  512.939    -0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000003     0.000001     0.000000     0.000018 
  515.923    -0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000003     0.000001     0.000000     0.000001 
  518.963    -0.000001     0.000000    -0.000001     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000001     0.000002 
  521.946    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000015 
  524.929    -0.000001    -0.000000     0.000001     0.000000     0.000001    -0.000001     0.000001     0.000000     0.000000     0.000002     0.000000     0.000000     0.000019 
  527.967    -0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000003     0.000001     0.000000     0.000003 
  530.949    -0.000001    -0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000003 
  533.987    -0.000000    -0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000001    -0.000001    -0.000001     0.000002 
  536.968    -0.000001    -0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000014    -0.000000     0.000000     0.000032 
  539.948    -0.000001    -0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000002     0.000001     0.000000     0.000015 
  542.984    -0.000001    -0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000002    -0.000000     0.000000     0.000001 
  545.964    -0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000000 
  548.999    -0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000    -0.000001     0.000000     0.000001 
  551.977     0.000000    -0.000001    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000001 
  555.012     0.000000    -0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000001 
  557.989    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000001 
  561.023     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000001 
  563.999     0.000000    -0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000001 
  567.032     0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000 
  570.007    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000 
  573.038    -0.000001    -0.000000    -0.000001     0.000001    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001 
  576.013     0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000 
  579.043    -0.000001    -0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000    -0.000001    -0.000000     0.000001 
  582.017    -0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000 
  585.046    -0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000 
  588.019     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000 
  591.047     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001 
  594.019     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000 
  597.046    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000001 
  600.073     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000001 
  603.043     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
  606.068    -0.000000    -0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000001 
  609.038     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001 
  612.062     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000 
  615.086     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001 
  618.053     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000 
  621.076     0.000001     0.000000    -0.000000     0.000000     0.000002     0.000001    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000001 
  624.099     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000001 
  627.064     0.000000     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  630.086     0.000001     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001 
  633.106     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002 
  636.071     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000001     0.000000     0.000001     0.000002 
  639.090     0.000001     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002 
  642.109     0.000002     0.000001     0.000002     0.000002     0.000003     0.000003     0.000002     0.000006     0.000002     0.000002     0.000002     0.000002     0.000008 
  645.128     0.000002     0.000005     0.000003     0.000002     0.000004     0.000004     0.000003     0.000002     0.000003     0.000003     0.000003     0.000003     0.000012 
  648.090     0.000014     0.000017     0.000014     0.000017     0.000015     0.000017     0.000013     0.000015     0.000016     0.000019     0.000017     0.000016     0.000018 
  651.107     0.000017     0.000024     0.000019     0.000023     0.000021     0.000020     0.000020     0.000016     0.000021     0.000025     0.000021     0.000024     0.000028 
  654.123     0.000034     0.000030     0.000026     0.000031     0.000031     0.000032     0.000026     0.000025     0.000032     0.000044     0.000036     0.000032     0.000049 
  657.139     0.000082     0.000081     0.000079     0.000078     0.000086     0.000079     0.000072     0.000070     0.000086     0.000102     0.000094     0.000093     0.000119 
  660.099     0.000123     0.000126     0.000119     0.000122     0.000131     0.000126     0.000117     0.000120     0.000140     0.000144     0.000135     0.000139     0.000166 
  663.114     0.000200     0.000201     0.000190     0.000193     0.000206     0.000199     0.000185     0.000184     0.000211     0.000259     0.000244     0.000232     0.000291 
  666.129     0.000394     0.000396     0.000382     0.000385     0.000408     0.000398     0.000373     0.000371     0.000426     0.000507     0.000480     0.000462     0.000569 
  669.142     0.000781     0.000772     0.000742     0.000753     0.000790     0.000774     0.000725     0.000715     0.000807     0.001051     0.000997     0.000928     0.001129 
  672.155     0.001765     0.001758     0.001689     0.001694     0.001784     0.001751     0.001643     0.001608     0.001818     0.002362     0.002247     0.002095     0.002604 
  675.168     0.003620     0.003624     0.003490     0.003494     0.003689     0.003630     0.003446     0.003378     0.003796     0.005062     0.004902     0.004412     0.005449 
  678.124     0.009988     0.009884     0.009476     0.009480     0.009903     0.009702     0.009255     0.008712     0.009712     0.015779     0.015075     0.013003     0.016358 
  681.136     0.029105     0.029146     0.028101     0.028267     0.029594     0.029410     0.027958     0.027143     0.030314     0.039459     0.037686     0.035503     0.043916 
  684.146     0.057089     0.056857     0.054921     0.055369     0.057519     0.057615     0.055121     0.053580     0.059295     0.085235     0.084481     0.072950     0.087768 
  687.157     0.191737     0.187046     0.180488     0.179132     0.184944     0.185289     0.176185     0.162561     0.178726     0.311870     0.303842     0.257600     0.309424 
  690.166     0.523012     0.522610     0.511864     0.508575     0.522364     0.526854     0.508738     0.493908     0.526180     0.656862     0.643226     0.611538     0.675024 
  693.175     0.781725     0.783566     0.773743     0.773253     0.782203     0.787924     0.775718     0.768105     0.788939     0.879417     0.870171     0.849360     0.883397 
  696.183     0.932200     0.935408     0.930337     0.931208     0.934452     0.938639     0.934823     0.933025     0.937536     0.952488     0.950505     0.952310     0.959482 
  699.191     0.935706     0.937830     0.934217     0.936601     0.938415     0.941434     0.938999     0.940803     0.943716     0.952321     0.950447     0.950230     0.956822 
  702.198     0.942996     0.945104     0.941526     0.943618     0.945328     0.949508     0.946617     0.947535     0.950334     0.958061     0.957043     0.957665     0.963228 
  705.205     0.943748     0.945669     0.942511     0.944874     0.945959     0.949773     0.948165     0.948889     0.950782     0.961036     0.960104     0.959803     0.964798 
  708.211     0.949705     0.952157     0.949088     0.950514     0.951929     0.955625     0.955627     0.955448     0.956795     0.970107     0.969879     0.968901     0.972414 
  711.216     0.957360     0.960573     0.957927     0.959249     0.959397     0.963198     0.964256     0.963236     0.964249     0.975693     0.975783     0.975808     0.979128 
  714.220     0.959941     0.963826     0.961843     0.962612     0.962824     0.966974     0.967208     0.967331     0.968335     0.974781     0.974633     0.976385     0.979476 
  717.224     0.954836     0.958639     0.956814     0.957514     0.958253     0.960507     0.961156     0.962398     0.963959     0.969905     0.969588     0.970477     0.973813 
  720.228     0.953804     0.956763     0.954153     0.954973     0.955924     0.959212     0.958512     0.959326     0.961775     0.971142     0.970395     0.969831     0.973840 
  723.230     0.955701     0.959050     0.956046     0.956877     0.957744     0.961727     0.961342     0.961961     0.964309     0.971523     0.971005     0.971453     0.975388 
  726.232     0.946908     0.950366     0.947863     0.949082     0.949649     0.953442     0.954425     0.955180     0.958702     0.960817     0.960160     0.961479     0.966179 
  729.234     0.939494     0.942855     0.938736     0.941680     0.941273     0.943966     0.944306     0.945143     0.949664     0.957967     0.956606     0.955874     0.962044 
  732.234     0.948437     0.950933     0.946861     0.949642     0.949466     0.952501     0.951786     0.952588     0.956138     0.966896     0.965836     0.964788     0.970845 
  735.235     0.950237     0.953696     0.949807     0.952222     0.951992     0.956929     0.955983     0.957462     0.960081     0.965261     0.965286     0.966106     0.969739 
  738.234     0.948789     0.951557     0.947984     0.950119     0.949786     0.955366     0.953393     0.954482     0.956975     0.967558     0.967343     0.966031     0.969888 
  741.233     0.956104     0.958576     0.955825     0.957122     0.957456     0.963445     0.961569     0.961554     0.963489     0.975163     0.975307     0.974487     0.977425 
  744.231     0.953977     0.957109     0.954813     0.955791     0.956679     0.962894     0.961792     0.962512     0.963562     0.969191     0.969693     0.971014     0.973046 
  747.228     0.949270     0.952406     0.949279     0.951650     0.951382     0.956358     0.954971     0.956124     0.957967     0.967265     0.966766     0.966495     0.969530 
  750.225     0.956802     0.959279     0.956548     0.957904     0.958538     0.963354     0.961646     0.961308     0.963327     0.975502     0.975317     0.974194     0.977632 
  753.221     0.959729     0.962340     0.960127     0.960711     0.961997     0.967005     0.966191     0.966355     0.967179     0.973488     0.973698     0.974285     0.976855 
  756.272     0.950122     0.953031     0.950047     0.952353     0.953226     0.957414     0.956385     0.957599     0.959907     0.962670     0.962272     0.963986     0.967118 
  759.267     0.943758     0.946098     0.943013     0.945565     0.946600     0.950514     0.947787     0.949327     0.953708     0.960195     0.959623     0.959390     0.964116 
  762.261     0.947671     0.949906     0.946568     0.948121     0.949518     0.952974     0.951031     0.951802     0.955631     0.966857     0.966958     0.965146     0.969985 
  765.254     0.953983     0.956206     0.953426     0.954174     0.955732     0.960634     0.958910     0.958994     0.961281     0.973154     0.974078     0.972099     0.975547 
  768.247     0.956765     0.959241     0.956569     0.957528     0.958715     0.964566     0.963124     0.963283     0.964526     0.975902     0.976944     0.975306     0.977806 
  771.294     0.957507     0.961210     0.957580     0.958726     0.959949     0.965774     0.964207     0.964784     0.966559     0.976417     0.977750     0.976393     0.979099 
  774.286     0.958186     0.961747     0.958784     0.959374     0.960497     0.966743     0.965673     0.965856     0.967211     0.976146     0.977374     0.976539     0.978923 
  777.277     0.957396     0.960802     0.957606     0.958261     0.959304     0.965613     0.964513     0.965061     0.966217     0.975178     0.975644     0.975267     0.977567 
  780.266     0.956663     0.959887     0.956883     0.957472     0.958460     0.965113     0.963519     0.963992     0.965033     0.974930     0.976208     0.975272     0.977205 
  783.311     0.956033     0.959424     0.956570     0.957123     0.957672     0.964940     0.963422     0.963723     0.964731     0.975076     0.976135     0.974772     0.977358 
  786.300     0.956074     0.959296     0.956720     0.956775     0.958079     0.965040     0.963601     0.963958     0.964983     0.975141     0.977079     0.975180     0.977763 
  789.288     0.954386     0.957920     0.955269     0.955540     0.956560     0.964033     0.962606     0.962805     0.964171     0.972842     0.974705     0.973392     0.976268 
  792.275     0.949271     0.953229     0.950665     0.950633     0.952204     0.959568     0.957995     0.958609     0.960128     0.966789     0.968452     0.968515     0.971599 
  795.316     0.943556     0.947428     0.944573     0.944803     0.946560     0.953263     0.951451     0.952500     0.954662     0.961571     0.962316     0.962278     0.966005 
  798.302     0.941793     0.944789     0.942008     0.943023     0.944273     0.950390     0.948397     0.949181     0.951321     0.960885     0.960595     0.960421     0.964300 
  801.287     0.944287     0.947651     0.944581     0.945719     0.946809     0.952576     0.950160     0.950587     0.952935     0.964637     0.965890     0.963868     0.968176 
  804.327     0.950075     0.953516     0.950604     0.951132     0.952183     0.958611     0.956728     0.956259     0.958107     0.971069     0.972903     0.970977     0.974612 
  807.310     0.953091     0.956539     0.954417     0.954596     0.956279     0.963399     0.962339     0.961079     0.962624     0.972977     0.976676     0.974522     0.978457 
  810.348     0.951398     0.954732     0.952326     0.953175     0.954112     0.961390     0.960624     0.960621     0.961607     0.971238     0.973571     0.972244     0.975103 
  813.331     0.949250     0.952841     0.949946     0.950574     0.951427     0.959097     0.957618     0.957881     0.958904     0.970530     0.971521     0.970317     0.972677 
  816.312     0.950255     0.953147     0.950665     0.951538     0.952357     0.959781     0.958238     0.957979     0.959519     0.970026     0.971732     0.970250     0.973426 
  819.348     0.945327     0.948910     0.945859     0.947443     0.948338     0.956204     0.954363     0.954987     0.956447     0.963688     0.965355     0.965194     0.968069 
  822.328     0.937596     0.940435     0.937113     0.939106     0.939919     0.947438     0.945169     0.946145     0.948736     0.957471     0.958534     0.957725     0.961774 
  825.362     0.936738     0.940510     0.936631     0.938286     0.939044     0.946289     0.943449     0.944772     0.947516     0.961574     0.961805     0.959965     0.964076 
  828.341     0.943662     0.947065     0.944228     0.945136     0.946216     0.954346     0.951675     0.951933     0.953784     0.968831     0.969816     0.967802     0.970955 
  831.374     0.939918     0.945592     0.942060     0.943534     0.944368     0.953385     0.950658     0.954903     0.954789     0.963105     0.963724     0.966092     0.966917 
  834.351     0.929755     0.934901     0.931323     0.932681     0.933870     0.942918     0.940341     0.943720     0.945307     0.953971     0.954528     0.955049     0.959410 
  837.382     0.932084     0.936434     0.932845     0.933296     0.934686     0.942380     0.939916     0.940837     0.943888     0.959989     0.960309     0.957329     0.963512 
  840.357     0.930633     0.937775     0.934400     0.935667     0.937251     0.948905     0.946725     0.948079     0.950341     0.955807     0.954632     0.961362     0.964268 
  843.387     0.823899     0.843669     0.840837     0.845509     0.851272     0.875824     0.873417     0.890459     0.895506     0.831608     0.827679     0.870473     0.875707 
  846.361     0.545659     0.573522     0.569437     0.580495     0.591226     0.626457     0.623171     0.659592     0.673699     0.533678     0.530697     0.600442     0.613574 
  849.389     0.259003     0.278202     0.273562     0.286139     0.293562     0.318361     0.314546     0.346955     0.363569     0.247613     0.244971     0.296301     0.306874 
  852.362     0.099822     0.107478     0.105029     0.111502     0.115452     0.125970     0.123224     0.138652     0.148961     0.094535     0.093265     0.115927     0.121719 
  855.389     0.037451     0.040178     0.039143     0.041421     0.043291     0.046921     0.045697     0.051475     0.056303     0.035652     0.035012     0.043232     0.046533 
  858.359     0.015100     0.016150     0.015732     0.016474     0.017401     0.018631     0.018078     0.020205     0.022319     0.014585     0.014221     0.017233     0.019069 
  861.385     0.006671     0.007103     0.006946     0.007220     0.007639     0.008099     0.007827     0.008703     0.009638     0.006555     0.006367     0.007547     0.008541 
  864.409     0.003297     0.003514     0.003417     0.003559     0.003746     0.003947     0.003803     0.004219     0.004678     0.003304     0.003195     0.003733     0.004256 
  867.378     0.001754     0.001858     0.001798     0.001892     0.001978     0.002075     0.001994     0.002201     0.002436     0.001787     0.001719     0.001995     0.002271 
  870.400     0.000987     0.001042     0.001007     0.001062     0.001107     0.001158     0.001110     0.001218     0.001350     0.001020     0.000972     0.001125     0.001280 
  873.422     0.000574     0.000601     0.000580     0.000612     0.000636     0.000664     0.000640     0.000699     0.000778     0.000592     0.000561     0.000650     0.000743 
  876.389     0.000345     0.000360     0.000349     0.000364     0.000378     0.000394     0.000381     0.000416     0.000471     0.000354     0.000335     0.000386     0.000450 
  879.409     0.000214     0.000224     0.000218     0.000225     0.000232     0.000246     0.000239     0.000255     0.000283     0.000220     0.000211     0.000234     0.000281 
  882.428     0.000136     0.000142     0.000136     0.000141     0.000155     0.000159     0.000151     0.000161     0.000179     0.000142     0.000123     0.000154     0.000186 
  885.447     0.000085     0.000092     0.000083     0.000097     0.000097     0.000106     0.000103     0.000099     0.000120     0.000078     0.000089     0.000102     0.000114 
  888.410     0.000058     0.000059     0.000060     0.000057     0.000061     0.000064     0.000059     0.000060     0.000071     0.000062     0.000053     0.000062     0.000070 
  891.427     0.000033     0.000035     0.000041     0.000030     0.000040     0.000037     0.000038     0.000038     0.000042     0.000038     0.000036     0.000039     0.000054 
  894.444     0.000025     0.000024     0.000032     0.000027     0.000028     0.000031     0.000027     0.000031     0.000029     0.000029     0.000027     0.000028     0.000027 
  897.459     0.000012     0.000025     0.000012     0.000023     0.000023     0.000025     0.000024     0.000024     0.000027     0.000022     0.000012     0.000015     0.000028 
  900.419     0.000003     0.000016     0.000009     0.000009     0.000020     0.000011     0.000012     0.000012     0.000004     0.000003     0.000010     0.000005     0.000004 
  903.433     0.000004     0.000001     0.000002     0.000001     0.000008     0.000004     0.000010     0.000012     0.000007     0.000004     0.000003     0.000006     0.000005 
  906.446     0.000002     0.000003     0.000003     0.000004     0.000002     0.000005     0.000001     0.000005     0.000004     0.000005     0.000004     0.000004     0.000002 
  909.458     0.000002     0.000003     0.000003     0.000003     0.000002     0.000004     0.000001     0.000003     0.000003     0.000003     0.000003     0.000004     0.000002 
  912.469     0.000002     0.000002     0.000002     0.000002     0.000002     0.000003     0.000002     0.000003     0.000002     0.000002     0.000002     0.000003     0.000002 
  915.480     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000001     0.000001     0.000002 
  918.489     0.000001     0.000001     0.000001     0.000001     0.000000     0.000002     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000001 
  921.443     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000001 
  924.451     0.000001     0.000001     0.000001     0.000001     0.000000     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002 
  927.458     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002 
  930.465     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000002 
  933.470     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001 
  936.475    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000001 
  939.478    -0.000000     0.000001    -0.000000     0.000000    -0.000001     0.000000     0.000000     0.000002    -0.000000     0.000001    -0.000001    -0.000000     0.000001 
  942.481    -0.000001     0.000000    -0.000000     0.000000    -0.000001     0.000000     0.000000     0.000002    -0.000000     0.000000    -0.000001     0.000000     0.000000 
  945.483    -0.000002     0.000000    -0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000001     0.000000    -0.000000    -0.000000     0.000001 
  948.484    -0.000001     0.000000    -0.000001     0.000001    -0.000000     0.000000     0.000000     0.000002    -0.000001     0.000000    -0.000000    -0.000000     0.000001 
  951.484    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000002     0.000000     0.000016     0.000001     0.000001     0.000028 
  954.538     0.000000     0.000002     0.000002     0.000001     0.000000     0.000001     0.000002     0.000002     0.000002     0.000000     0.000002     0.000002     0.000006 
  957.537    -0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000001    -0.000000     0.000000     0.000002     0.000000 
  960.534    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000001    -0.000001    -0.000000     0.000000 
  963.531    -0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000000 
  966.526    -0.000001     0.000001     0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000001    -0.000000    -0.000001    -0.000000    -0.000000     0.000000 
  969.521    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000001 
  972.515    -0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000000    -0.000000    -0.000001     0.000001 
  975.563     0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000001     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000 
  978.555     0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000001     0.000000 
  981.546     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000000    -0.000000    -0.000001    -0.000001     0.000000 
  984.537     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000000 
  987.580     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001 
  990.569    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  993.556    -0.000001     0.000001    -0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000 
  996.543     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000 
  999.583     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000 
 1002.568     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000 
 1005.552     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
 1008.589    -0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
 1011.571    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000000 
 1014.606    -0.000000    -0.000000     0.000001    -0.000000     0.000001    -0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000 
 1017.587    -0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000001 
 1020.620    -0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000001    -0.000001     0.000000    -0.000001     0.000001 
 1023.598    -0.000001    -0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000000     0.000000    -0.000000     0.000001 
 1026.629    -0.000001     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000001 
 1029.606    -0.000001    -0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000000    -0.000000    -0.000001     0.000000    -0.000001     0.000000 
 1032.635    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000001    -0.000000 
 1035.610    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000001     0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000001     0.000001 
 1038.637    -0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000001     0.000001 
 1041.610     0.000000     0.000000     0.000001    -0.000001     0.000001    -0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000001     0.000001 
 1044.635    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000001     0.000001     0.000000    -0.000001    -0.000001     0.000000     0.000000 
 1047.660     0.000000    -0.000000     0.000002     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000000    -0.000001     0.000001 
 1050.629     0.000001     0.000000     0.000000    -0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000000    -0.000001     0.000001 
 1053.652    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000002    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1056.620    -0.000000     0.000001    -0.000001    -0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000001 
 1059.640    -0.000001    -0.000000     0.000000    -0.000001     0.000000     0.000002     0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000001     0.000000 
 1062.660    -0.000002    -0.000001     0.000002     0.000001     0.000002     0.000001     0.000000     0.000000    -0.000001    -0.000001     0.000001     0.000000    -0.000000 
 1065.678    -0.000001    -0.000000     0.000002     0.000001    -0.000000     0.000002     0.000001     0.000002    -0.000001    -0.000000     0.000000     0.000002     0.000000 
 1068.642    -0.000000    -0.000001     0.000001     0.000001     0.000001     0.000000     0.000003     0.000002    -0.000001    -0.000002    -0.000001    -0.000001     0.000001 
 1071.658     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000002     0.000000     0.000002    -0.000001    -0.000003    -0.000000    -0.000001     0.000001 
 1074.674    -0.000002    -0.000002     0.000000     0.000002    -0.000001     0.000002     0.000000     0.000001     0.000001    -0.000004    -0.000001    -0.000000     0.000003 
 1077.688    -0.000003    -0.000003     0.000001     0.000003     0.000002     0.000001     0.000001     0.000001     0.000002    -0.000002    -0.000001    -0.000000     0.000001 
 1080.702    -0.000002    -0.000001     0.000001     0.000003    -0.000000    -0.000002     0.000000     0.000002    -0.000000    -0.000003     0.000001    -0.000003     0.000002 
 1083.660    -0.000001    -0.000002     0.000001    -0.000001     0.000000     0.000001     0.000000     0.000002    -0.000001    -0.000004     0.000001     0.000001     0.000003 
 1086.672     0.000001    -0.000002     0.000002     0.000001     0.000001     0.000001     0.000002     0.000003     0.000000    -0.000004     0.000001    -0.000000     0.000001 
 1089.682    -0.000000    -0.000002     0.000003     0.000002     0.000004    -0.000002     0.000001     0.000002     0.000002    -0.000003    -0.000000    -0.000003     0.000004 
 1092.691    -0.000002    -0.000003     0.000004    -0.000001    -0.000002    -0.000002     0.000001     0.000004     0.000001    -0.000001     0.000003    -0.000000     0.000005 
 1095.699     0.000002    -0.000003     0.000003     0.000001     0.000002     0.000005     0.000003     0.000005     0.000004    -0.000000     0.000002     0.000001     0.000003 
 1098.707     0.000000    -0.000000     0.000004     0.000004     0.000000     0.000009     0.000001     0.000004     0.000002    -0.000004    -0.000002     0.000002     0.000003 
 1101.713    -0.000000    -0.000004     0.000002     0.000003    -0.000001     0.000003    -0.000001     0.000005     0.000002    -0.000002     0.000000    -0.000001     0.000004 
 1104.718    -0.000002    -0.000007    -0.000001     0.000002     0.000001     0.000005     0.000003     0.000006    -0.000000    -0.000004    -0.000001    -0.000001     0.000000 
 1107.722     0.000000    -0.000004     0.000001     0.000004     0.000002     0.000002     0.000001     0.000005     0.000001    -0.000004    -0.000004    -0.000000     0.000000 
 1110.725     0.000005    -0.000003    -0.000001     0.000003    -0.000003     0.000007    -0.000001     0.000001    -0.000002    -0.000001    -0.000002    -0.000000    -0.000003 
 1113.727     0.000003    -0.000003    -0.000007     0.000003     0.000003     0.000004     0.000001     0.000002    -0.000001    -0.000004    -0.000003    -0.000001     0.000001 
 1116.728    -0.000002    -0.000004    -0.000006    -0.000002     0.000001     0.000002     0.000003     0.000003    -0.000000    -0.000008    -0.000002     0.000002     0.000003 
 1119.728     0.000001    -0.000006    -0.000004     0.000001     0.000004     0.000003    -0.000003     0.000003     0.000002    -0.000006    -0.000005     0.000002    -0.000004 
 1122.726     0.000004    -0.000007     0.000003     0.000000     0.000004     0.000008     0.000000     0.000005     0.000003     0.000002    -0.000005     0.000007     0.000001 
 1125.724     0.000003    -0.000003     0.000007     0.000005     0.000006     0.000010     0.000011     0.000004     0.000002     0.000007     0.000004     0.000010     0.000009 
 1128.720     0.000002     0.000009     0.000009     0.000010     0.000017     0.000009     0.000005     0.000018     0.000013     0.000010     0.000003     0.000020     0.000019 
 1131.770     0.000012     0.000008     0.000011     0.000024     0.000013     0.000025     0.000010     0.000023     0.000024     0.000002     0.000009     0.000015     0.000013 
 1134.764     0.000006     0.000004     0.000011     0.000017     0.000011     0.000012    -0.000007     0.000009     0.000021     0.000000     0.000006     0.000021     0.000001 
 1137.757     0.000008    -0.000004     0.000012     0.000006     0.000018     0.000006     0.000000     0.000017     0.000010    -0.000010    -0.000001     0.000010    -0.000003 
 1140.749    -0.000001    -0.000003     0.000007     0.000019     0.000004     0.000005     0.000002     0.000015     0.000006    -0.000005    -0.000007     0.000010     0.000015 
 1143.741    -0.000015     0.000006     0.000003     0.000008     0.000013     0.000001    -0.000002     0.000017     0.000002    -0.000004    -0.000010     0.000015     0.000016 
 1146.784     0.000006    -0.000009     0.000006     0.000009     0.000007     0.000009    -0.000005     0.000004    -0.000003     0.000018    -0.000021     0.000017     0.000011 
 1149.773    -0.000018     0.000008     0.000001     0.000022    -0.000000     0.000030     0.000000     0.000019     0.000014    -0.000007    -0.000004     0.000027     0.000004 
 1152.761     0.000005    -0.000021     0.000005     0.000018    -0.000014     0.000031     0.000007    -0.000002     0.000006    -0.000015     0.000021     0.000028     0.000005 
 1155.801    -0.000002    -0.000009     0.000025     0.000036     0.000022     0.000025     0.000008     0.000013     0.000003     0.000022     0.000020     0.000039     0.000051 
 1158.786     0.000006     0.000047     0.000025     0.000056     0.000031     0.000047     0.000027     0.000020     0.000034     0.000026     0.000058     0.000058     0.000052 
 1161.771     0.000033     0.000062     0.000068     0.000077     0.000095     0.000092     0.000075     0.000045     0.000041     0.000329     0.000374     0.000123     0.000404 
 1164.807     0.000400     0.000113     0.000120     0.000138     0.000095     0.000496     0.000142     0.000119     0.000149     0.001028     0.001288     0.000921     0.001662 
 1167.790     0.001000     0.001159     0.001186     0.001311     0.001311     0.001414     0.001342     0.001483     0.001593     0.001792     0.001520     0.002022     0.002117 
 1170.771     0.001961     0.001839     0.001530     0.002044     0.001915     0.001781     0.001727     0.001773     0.002489     0.001820     0.001764     0.001782     0.002259 
 1173.804     0.001851     0.002063     0.002131     0.002124     0.002126     0.002014     0.002017     0.002112     0.002079     0.001828     0.000538     0.002049     0.001830 
 1176.783     0.000222     0.001244     0.001050     0.000519     0.000519     0.000195     0.000234     0.000326     0.000526    -0.000014     0.000545     0.000220     0.001236 
 1179.814     0.000921     0.001021     0.000293     0.000771     0.000839     0.000648     0.000759     0.000873     0.000951     0.000220     0.000947     0.000506     0.000469 
 1182.790     0.000578     0.000616     0.000931     0.000870     0.000681     0.000753     0.000401     0.000572     0.000999     0.000459     0.000895     0.000662     0.000833 
 1185.819     0.000934     0.000478     0.000417     0.000860     0.000685     0.000658     0.000322     0.000478     0.000972     0.000189     0.000862     0.000399     0.000786 
 1188.793     0.000256     0.000274     0.000503     0.000808     0.001064     0.000419     0.000932     0.000805     0.000874     0.000232     0.000612     0.000772     0.000879 
 1191.820     0.000305     0.000145     0.000414     0.001233     0.000809     0.001124     0.000555     0.000774     0.000954     0.000023     0.000813     0.000920     0.001378 
 1194.845     0.000454     0.000694     0.000806     0.001106     0.001258     0.000995     0.000324     0.000372     0.001008     0.000912     0.000947     0.001559     0.001998 
 1197.815     0.000791     0.001207     0.001487     0.001319     0.001752     0.001564     0.000902     0.000696     0.001946     0.001801     0.002466     0.002925     0.003446 
 1200.838     0.002071     0.001566     0.001282     0.001714     0.002491     0.003300     0.001958     0.002172     0.002000     0.018905     0.020913     0.004659     0.014266 