# number of points on sci filter + aux + bad z = 2
# number of points on sci filter               = 2
# number of positions in lambda                = 301
# noof scans  1            1          
# x_pos     162.640000  -162.640000 
# y_pos       0.000000     0.000000 
# angle       2.960000     2.960000 
# z_pos      10.000000    10.000000 
# r_pos     162.640000   162.640000 
# phi         0.000000     3.141593 
# gnupl col      2            3      
# pos_id        49           50      
#
# lambda for peak transmission
#          579.0430000  585.0460000 
# peak transmission
#            0.9735040    0.9743030 
# lambda blue with 1/2 of peak transmission
#          551.0397776  551.1537107 
# lambda red  with 1/2 of peak transmission
#          701.2223958  701.0163514 
# half width                              
#          150.1826182  149.8626407 
# central wavelength                      
#          626.1310867  626.0850310 
# central wavelength calculated as SAGEM (mean frequency)
#          617.1254570  617.1170754 
# lambda blue with 80% of peak transmission
#          553.9009095  553.9982888 
# lambda red  with 80% of peak transmission
#          698.8947836  698.5279356 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.9631768    0.9638570 
# ATB calculated from points above 50%
#            0.9522337    0.9521453 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000 
# minCWL      = 626.085031 at column =  3, at id = 50 
# maxCWL      = 626.131087 at column =  2, at id = 49 
# difference =    0.0460557 
# minBW       = 149.862641 at column =  3, at id = 50 
# maxBW       = 150.182618 at column =  2, at id = 49 
# difference =    0.3199775 
# minATB80    = 0.963177 at column =  2, at id = 49 
# maxATB80    = 0.963857 at column =  3, at id = 50 
# difference =    0.0006801 
# minBlueEdge = 551.039778 at column =  2, at id = 49 
# maxBlueEdge = 551.153711 at column =  3, at id = 50 
# difference =    0.1139330 
# minRedEdge  = 701.016351 at column =  3, at id = 50 
# maxRedEdge  = 701.222396 at column =  2, at id = 49 
# difference =    0.2060444 
# minABR      = 9.999900 at column =  2, at id = 49 
# maxABR      = 9.999900 at column =  2, at id = 49 
# difference =    0.0000000 
  299.645    -0.000089     0.000625 
  302.654    -0.000101     0.000218 
  305.662    -0.000064     0.000021 
  308.671    -0.000008     0.000042 
  311.679    -0.000014    -0.000010 
  314.687    -0.000005    -0.000002 
  317.694     0.000029     0.000022 
  320.702    -0.000016     0.000011 
  323.709    -0.000013     0.000006 
  326.716    -0.000003     0.000014 
  329.665    -0.000002     0.000004 
  332.672    -0.000004     0.000001 
  335.678    -0.000014     0.000003 
  338.683    -0.000017     0.000006 
  341.689    -0.000014     0.000002 
  344.694    -0.000011    -0.000005 
  347.699    -0.000016    -0.000004 
  350.703    -0.000007    -0.000001 
  353.707    -0.000001     0.000004 
  356.711    -0.000003     0.000002 
  359.715     0.000000     0.000001 
  362.718    -0.000003    -0.000001 
  365.721    -0.000003     0.000004 
  368.724    -0.000001     0.000000 
  371.726     0.000003    -0.000000 
  374.728     0.000003     0.000003 
  377.730     0.000001     0.000000 
  380.788     0.000001    -0.000001 
  383.789     0.000000    -0.000000 
  386.789    -0.000000    -0.000001 
  389.790    -0.000001     0.000001 
  392.790     0.000000    -0.000000 
  395.790    -0.000001    -0.000001 
  398.789    -0.000004    -0.000001 
  401.788    -0.000001    -0.000001 
  404.787    -0.000003    -0.000000 
  407.785    -0.000001     0.000002 
  410.783    -0.000001     0.000000 
  413.781     0.000000     0.000001 
  416.834     0.000001     0.000001 
  419.831     0.000000     0.000002 
  422.828     0.000002     0.000001 
  425.824     0.000003     0.000001 
  428.820     0.000002     0.000003 
  431.815     0.000002     0.000001 
  434.810     0.000003     0.000001 
  437.862     0.000001     0.000001 
  440.856     0.000001     0.000000 
  443.850     0.000000     0.000000 
  446.844     0.000000    -0.000000 
  449.837     0.000000     0.000000 
  452.830     0.000000     0.000000 
  455.878     0.000000     0.000000 
  458.870     0.000001    -0.000000 
  461.862     0.000001     0.000001 
  464.853     0.000001    -0.000000 
  467.901     0.000000     0.000000 
  470.891     0.000001     0.000001 
  473.881     0.000000     0.000000 
  476.871     0.000002    -0.000000 
  479.916     0.000001     0.000001 
  482.905     0.000002     0.000001 
  485.894     0.000001     0.000001 
  488.882     0.000002     0.000001 
  491.925     0.000002     0.000001 
  494.913     0.000001     0.000001 
  497.899     0.000001     0.000001 
  500.942     0.000002     0.000002 
  503.928     0.000000     0.000001 
  506.913     0.000002     0.000001 
  509.954     0.000002     0.000002 
  512.939     0.000003     0.000002 
  515.923     0.000018     0.000019 
  518.963     0.000028     0.000024 
  521.946     0.000038     0.000031 
  524.929     0.000074     0.000068 
  527.967     0.000164     0.000149 
  530.949     0.000354     0.000328 
  533.987     0.000737     0.000678 
  536.968     0.001629     0.001516 
  539.948     0.005146     0.004791 
  542.984     0.019616     0.018151 
  545.964     0.063774     0.059210 
  548.999     0.214424     0.204116 
  551.977     0.611818     0.595296 
  555.012     0.875240     0.871795 
  557.989     0.934652     0.933433 
  561.023     0.943953     0.945065 
  563.999     0.963782     0.965266 
  567.032     0.966784     0.968959 
  570.007     0.960458     0.961974 
  573.038     0.967460     0.969407 
  576.013     0.972082     0.973052 
  579.043     0.973504     0.974202 
  582.017     0.971982     0.973513 
  585.046     0.973081     0.974303 
  588.019     0.971342     0.972219 
  591.047     0.967773     0.967958 
  594.019     0.967490     0.968248 
  597.046     0.964004     0.963883 
  600.073     0.966520     0.968086 
  603.043     0.963297     0.963826 
  606.068     0.962177     0.964030 
  609.038     0.972253     0.973157 
  612.062     0.971004     0.971389 
  615.086     0.970727     0.971000 
  618.053     0.970659     0.972673 
  621.076     0.972012     0.973702 
  624.099     0.968077     0.969717 
  627.064     0.969375     0.970156 
  630.086     0.972916     0.972888 
  633.106     0.971852     0.973511 
  636.071     0.970885     0.971969 
  639.090     0.971591     0.972708 
  642.109     0.969180     0.969306 
  645.128     0.963721     0.965053 
  648.090     0.969648     0.970865 
  651.107     0.969355     0.970956 
  654.123     0.965933     0.967111 
  657.139     0.962017     0.963369 
  660.099     0.959487     0.958995 
  663.114     0.970923     0.972201 
  666.129     0.969668     0.970075 
  669.142     0.968718     0.970666 
  672.155     0.966441     0.966657 
  675.168     0.956104     0.956809 
  678.124     0.957241     0.958000 
  681.136     0.962057     0.960373 
  684.146     0.962844     0.961859 
  687.157     0.970436     0.971213 
  690.166     0.970455     0.972361 
  693.175     0.963508     0.963033 
  696.183     0.908546     0.904891 
  699.191     0.764631     0.743970 
  702.198     0.353297     0.320899 
  705.205     0.070901     0.063525 
  708.211     0.021943     0.020068 
  711.216     0.009433     0.008389 
  714.220     0.002545     0.002250 
  717.224     0.000811     0.000732 
  720.228     0.000399     0.000363 
  723.230     0.000179     0.000161 
  726.232     0.000079     0.000075 
  729.234     0.000052     0.000047 
  732.234     0.000042     0.000036 
  735.235     0.000023     0.000020 
  738.234     0.000001     0.000001 
  741.233     0.000001     0.000001 
  744.231    -0.000001    -0.000000 
  747.228    -0.000000     0.000000 
  750.225     0.000000     0.000001 
  753.221    -0.000001     0.000000 
  756.272    -0.000002    -0.000001 
  759.267    -0.000000    -0.000000 
  762.261    -0.000002    -0.000001 
  765.254    -0.000002    -0.000001 
  768.247    -0.000001    -0.000001 
  771.294    -0.000001    -0.000000 
  774.286    -0.000000     0.000000 
  777.277    -0.000001    -0.000000 
  780.266    -0.000001    -0.000000 
  783.311    -0.000001    -0.000000 
  786.300     0.000000     0.000000 
  789.288     0.000000    -0.000000 
  792.275    -0.000000    -0.000000 
  795.316    -0.000001    -0.000001 
  798.302    -0.000002    -0.000000 
  801.287    -0.000001    -0.000000 
  804.327    -0.000001    -0.000000 
  807.310     0.000000     0.000001 
  810.348    -0.000002     0.000000 
  813.331     0.000000     0.000000 
  816.312    -0.000001    -0.000000 
  819.348    -0.000001    -0.000000 
  822.328    -0.000000     0.000001 
  825.362    -0.000000    -0.000000 
  828.341     0.000001     0.000001 
  831.374     0.000001    -0.000001 
  834.351    -0.000000     0.000002 
  837.382     0.000001    -0.000000 
  840.357     0.000000     0.000001 
  843.387     0.000000     0.000002 
  846.361    -0.000001     0.000001 
  849.389     0.000000     0.000001 
  852.362    -0.000001    -0.000001 
  855.389    -0.000000    -0.000000 
  858.359     0.000000    -0.000001 
  861.385     0.000000    -0.000001 
  864.409    -0.000001     0.000000 
  867.378    -0.000001     0.000001 
  870.400    -0.000001    -0.000001 
  873.422    -0.000001     0.000001 
  876.389    -0.000002    -0.000001 
  879.409    -0.000000     0.000001 
  882.428    -0.000001     0.000000 
  885.447    -0.000001     0.000000 
  888.410    -0.000001     0.000001 
  891.427    -0.000002    -0.000001 
  894.444    -0.000001    -0.000001 
  897.459    -0.000002    -0.000000 
  900.419    -0.000001    -0.000000 
  903.433    -0.000000    -0.000001 
  906.446    -0.000001    -0.000001 
  909.458    -0.000001    -0.000000 
  912.469    -0.000001    -0.000001 
  915.480    -0.000001    -0.000001 
  918.489    -0.000001    -0.000000 
  921.443    -0.000001    -0.000000 
  924.451    -0.000000    -0.000000 
  927.458    -0.000000    -0.000000 
  930.465     0.000000    -0.000000 
  933.470    -0.000000    -0.000001 
  936.475    -0.000001    -0.000001 
  939.478    -0.000001    -0.000001 
  942.481    -0.000001    -0.000001 
  945.483    -0.000001    -0.000000 
  948.484     0.000000    -0.000000 
  951.484    -0.000000     0.000000 
  954.538    -0.000000    -0.000000 
  957.537    -0.000001    -0.000001 
  960.534     0.000000    -0.000000 
  963.531    -0.000001    -0.000001 
  966.526     0.000000    -0.000001 
  969.521     0.000000    -0.000000 
  972.515     0.000000    -0.000001 
  975.563    -0.000000     0.000000 
  978.555    -0.000000     0.000000 
  981.546     0.000000    -0.000000 
  984.537     0.000000    -0.000000 
  987.580     0.000000     0.000000 
  990.569    -0.000000    -0.000000 
  993.556    -0.000000     0.000000 
  996.543     0.000000    -0.000000 
  999.583     0.000001     0.000001 
 1002.568     0.000002    -0.000000 
 1005.552     0.000000    -0.000000 
 1008.589     0.000001    -0.000000 
 1011.571     0.000000    -0.000001 
 1014.606     0.000001    -0.000001 
 1017.587     0.000001    -0.000000 
 1020.620     0.000001    -0.000001 
 1023.598     0.000001    -0.000002 
 1026.629     0.000000    -0.000001 
 1029.606     0.000002    -0.000001 
 1032.635     0.000001    -0.000001 
 1035.610     0.000001    -0.000001 
 1038.637     0.000001    -0.000001 
 1041.610     0.000001    -0.000001 
 1044.635     0.000001    -0.000002 
 1047.660     0.000001    -0.000001 
 1050.629     0.000002    -0.000001 
 1053.652     0.000000    -0.000001 
 1056.620     0.000002    -0.000003 
 1059.640     0.000002    -0.000001 
 1062.660     0.000006     0.000037 
 1065.678     0.000032     0.000017 
 1068.642     0.000001     0.000004 
 1071.658     0.000007     0.000002 
 1074.674     0.000005    -0.000002 
 1077.688     0.000002    -0.000002 
 1080.702     0.000004    -0.000001 
 1083.660     0.000001    -0.000001 
 1086.672     0.000007     0.000003 
 1089.682     0.000006     0.000003 
 1092.691     0.000074     0.000071 
 1095.699     0.000130     0.000129 
 1098.707     0.000133     0.000111 
 1101.713     0.000102     0.000047 
 1104.718     0.000014     0.000041 
 1107.722     0.000018     0.000010 
 1110.725     0.000031     0.000020 
 1113.727     0.000030     0.000026 
 1116.728     0.000031     0.000028 
 1119.728     0.000042     0.000031 
 1122.726     0.000049     0.000043 
 1125.724     0.000128     0.000049 
 1128.720     0.000292     0.000279 
 1131.770     0.000500     0.000490 
 1134.764     0.000583     0.000534 
 1137.757     0.000382     0.000381 
 1140.749     0.000349     0.000290 
 1143.741     0.000202     0.000134 
 1146.784     0.000228     0.000127 
 1149.773     0.000242     0.000170 
 1152.761     0.000298     0.000131 
 1155.801     0.000332     0.000129 
 1158.786     0.000268     0.000414 
 1161.771     0.000278     0.000398 
 1164.807     0.000313     0.000451 
 1167.790     0.000548     0.000433 
 1170.771     0.001143     0.000868 
 1173.804     0.001859     0.001279 
 1176.783     0.003184     0.002707 
 1179.814     0.004808     0.004849 
 1182.790     0.006653     0.006570 
 1185.819     0.005682     0.000536 
 1188.793     0.002252     0.001760 
 1191.820     0.002775     0.002993 
 1194.845     0.002988     0.002423 
 1197.815     0.003171     0.002620 
 1200.838     0.003546     0.004250 
