# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     1.490000     1.490000     2.110000     2.500000     1.320000     1.320000     2.500000 
# z_pos      57.000000    56.000000    56.000000    57.000000    58.000000    55.000000    55.000000    58.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       421          422          423          424          425          426          427          428      
#
# lambda for peak transmission
#          482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  479.9160000  482.9050000 
# peak transmission
#            0.8744730    0.8614400    0.8496990    0.8619560    0.8846710    0.8537830    0.8321090    0.8538140 
# lambda blue with 1/2 of peak transmission
#          386.0846179  385.9858309  385.7151346  385.9874387  385.9716195  385.9333477  385.1914166  385.9096348 
# lambda red  with 1/2 of peak transmission
#          491.2255583  491.3374410  491.0506655  491.2222390  490.7022633  491.2890483  490.4106702  490.9450756 
# half width                              
#          105.1409403  105.3516101  105.3355310  105.2348002  104.7306438  105.3557007  105.2192536  105.0354408 
# central wavelength                      
#          438.6550881  438.6616360  438.3829000  438.6048389  438.3369414  438.6111980  437.8010434  438.4273552 
# central wavelength calculated as SAGEM (mean frequency)
#          432.3547979  432.3361673  432.0553414  432.2925720  432.0811900  432.2845106  431.4790557  432.1364363 
# lambda blue with 80% of peak transmission
#          392.3917422  394.2589546  396.2848713  393.9330495  391.8783693  395.4337818  400.2031801  395.1901455 
# lambda red  with 80% of peak transmission
#          488.9919398  489.0620783  488.7435227  488.9514462  488.2681538  489.0232178  487.7825682  488.5710096 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.8057254    0.7893148    0.7806302    0.7901298    0.8226644    0.7803352    0.7632712    0.7827016 
# ATB calculated from points above 50%
#            0.7917842    0.7726358    0.7578866    0.7734904    0.8044203    0.7637179    0.7356267    0.7627132 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 437.801043 at column =  8, at id = 427 
# maxCWL      = 438.661636 at column =  3, at id = 422 
# difference =    0.8605925 
# minBW       = 104.730644 at column =  6, at id = 425 
# maxBW       = 105.355701 at column =  7, at id = 426 
# difference =    0.6250569 
# minATB80    = 0.763271 at column =  8, at id = 427 
# maxATB80    = 0.822664 at column =  6, at id = 425 
# difference =    0.0593933 
# minBlueEdge = 385.191417 at column =  8, at id = 427 
# maxBlueEdge = 386.084618 at column =  2, at id = 421 
# difference =    0.8932013 
# minRedEdge  = 490.410670 at column =  8, at id = 427 
# maxRedEdge  = 491.337441 at column =  3, at id = 422 
# difference =    0.9267707 
# minABR      = 9.999900 at column =  2, at id = 421 
# maxABR      = 9.999900 at column =  2, at id = 421 
# difference =    0.0000000 
  359.715     0.000003     0.000005     0.000005     0.000005     0.000007     0.000000     0.000002     0.000000 
  362.718     0.000003     0.000003     0.000004     0.000002     0.000001     0.000003     0.000001     0.000003 
  365.721     0.000000     0.000005    -0.000002     0.000001    -0.000001     0.000003     0.000002     0.000000 
  368.724    -0.000002     0.000003     0.000004    -0.000004    -0.000002     0.000002    -0.000001     0.000004 
  371.726     0.000000     0.000003     0.000001     0.000001    -0.000002     0.000002    -0.000000     0.000003 
  374.728     0.000003     0.000002     0.000071     0.000002     0.000004     0.000009     0.000313     0.000005 
  377.730     0.004436     0.006224     0.010214     0.006607     0.004498     0.007372     0.018587     0.008044 
  380.788     0.052917     0.060354     0.078235     0.061496     0.055340     0.065282     0.120006     0.068727 
  383.789     0.255018     0.274332     0.309675     0.275991     0.268882     0.283539     0.353438     0.290881 
  386.789     0.493148     0.487896     0.489062     0.487487     0.507293     0.484093     0.487385     0.483313 
  389.790     0.629987     0.614077     0.607496     0.616672     0.654175     0.605833     0.592215     0.611222 
  392.790     0.710231     0.681747     0.659631     0.683395     0.731118     0.669017     0.627528     0.669852 
  395.790     0.725874     0.696870     0.677236     0.699588     0.746425     0.684914     0.649353     0.686350 
  398.789     0.742891     0.714728     0.692527     0.716158     0.761507     0.702632     0.658729     0.702175 
  401.788     0.746094     0.717916     0.698967     0.720467     0.765906     0.705866     0.673485     0.707457 
  404.787     0.761950     0.734234     0.714212     0.735749     0.780064     0.722307     0.686714     0.722512 
  407.785     0.763593     0.736585     0.716079     0.737943     0.780874     0.725104     0.686527     0.724405 
  410.783     0.760608     0.734277     0.715852     0.736331     0.777922     0.723662     0.691353     0.723461 
  413.781     0.763193     0.739951     0.723902     0.740874     0.780664     0.729632     0.705390     0.729892 
  416.834     0.781181     0.758646     0.742290     0.759716     0.798311     0.747935     0.718382     0.748677 
  419.831     0.789715     0.765775     0.749264     0.767372     0.806180     0.755378     0.728232     0.755933 
  422.828     0.792936     0.770446     0.754652     0.771817     0.807737     0.760396     0.733336     0.760896 
  425.824     0.796222     0.774392     0.757955     0.775587     0.812383     0.764891     0.734427     0.764564 
  428.820     0.798412     0.777161     0.762367     0.778976     0.813902     0.767650     0.744272     0.768083 
  431.815     0.803463     0.782501     0.767667     0.783999     0.818180     0.773068     0.748014     0.773042 
  434.810     0.803165     0.781590     0.763800     0.781979     0.816541     0.771648     0.740505     0.769449 
  437.862     0.794527     0.778012     0.770195     0.779595     0.809781     0.770548     0.760095     0.772262 
  440.856     0.822213     0.803960     0.791371     0.805098     0.836414     0.795520     0.771643     0.796357 
  443.850     0.821914     0.801805     0.786078     0.802580     0.833711     0.793310     0.762363     0.791364 
  446.844     0.803488     0.785829     0.774424     0.786409     0.815701     0.778179     0.761764     0.777468 
  449.837     0.832490     0.816405     0.806823     0.818461     0.847574     0.808918     0.789571     0.810744 
  452.830     0.843061     0.825822     0.813392     0.827483     0.855014     0.817972     0.790827     0.818195 
  455.878     0.844694     0.826425     0.809619     0.827727     0.857047     0.818319     0.783178     0.817272 
  458.870     0.844878     0.827591     0.815957     0.829257     0.857328     0.820224     0.802177     0.820468 
  461.862     0.852391     0.837035     0.826521     0.838262     0.863257     0.829866     0.811199     0.829727 
  464.853     0.853862     0.837896     0.825575     0.838731     0.864569     0.830385     0.807601     0.829550 
  467.901     0.850793     0.834061     0.822361     0.835247     0.861515     0.827800     0.804275     0.826457 
  470.891     0.850498     0.834995     0.825069     0.836371     0.862428     0.828439     0.813217     0.828656 
  473.881     0.865162     0.850581     0.839633     0.852038     0.875513     0.844104     0.819101     0.843552 
  476.871     0.855078     0.841202     0.831143     0.841932     0.864298     0.834170     0.819086     0.833800 
  479.916     0.863590     0.851817     0.844671     0.852708     0.872689     0.845368     0.832109     0.845387 
  482.905     0.874473     0.861440     0.849699     0.861956     0.884671     0.853783     0.829340     0.853814 
  485.894     0.863208     0.847997     0.826687     0.845666     0.865885     0.839169     0.786505     0.831567 
  488.882     0.712491     0.709605     0.672619     0.697473     0.666847     0.698990     0.595353     0.665798 
  491.925     0.355086     0.363986     0.324957     0.350951     0.291523     0.355002     0.238438     0.313438 
  494.913     0.092611     0.095550     0.080463     0.090101     0.070197     0.091933     0.054814     0.076285 
  497.899     0.020895     0.022273     0.020240     0.021092     0.016430     0.021856     0.016251     0.018719 
  500.942     0.007219     0.007799     0.007142     0.007395     0.005792     0.007685     0.005569     0.006619 
  503.928     0.002639     0.002804     0.002451     0.002627     0.002129     0.002729     0.001788     0.002316 
  506.913     0.000873     0.000942     0.000907     0.000899     0.000728     0.000934     0.000833     0.000831 
  509.954     0.000453     0.000495     0.000472     0.000471     0.000374     0.000493     0.000413     0.000436 
  512.939     0.000222     0.000236     0.000231     0.000234     0.000190     0.000245     0.000192     0.000216 
  515.923     0.000096     0.000104     0.000097     0.000100     0.000083     0.000106     0.000085     0.000090 
  518.963     0.000050     0.000058     0.000057     0.000051     0.000042     0.000056     0.000052     0.000050 
  521.946     0.000034     0.000036     0.000035     0.000038     0.000032     0.000040     0.000034     0.000036 
  524.929     0.000020     0.000023     0.000022     0.000026     0.000022     0.000027     0.000022     0.000023 
  527.967     0.000015     0.000018     0.000018     0.000017     0.000015     0.000016     0.000020     0.000019 
  530.949     0.000016     0.000012     0.000014     0.000014     0.000007     0.000016     0.000016     0.000008 
  533.987     0.000014     0.000015     0.000015     0.000015     0.000008     0.000014     0.000016     0.000013 
  536.968     0.000001     0.000002     0.000006     0.000001     0.000005     0.000006     0.000013     0.000001 
  539.948     0.000003     0.000004     0.000004     0.000003     0.000003     0.000005     0.000002     0.000003 
  542.984     0.000003     0.000003     0.000003     0.000003     0.000003     0.000004     0.000003     0.000003 
  545.964     0.000002     0.000004     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003 
  548.999     0.000003     0.000003     0.000002     0.000002     0.000003     0.000002     0.000002     0.000002 
  551.977     0.000002     0.000002     0.000002     0.000002     0.000003     0.000002     0.000002     0.000002 
  555.012     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000001     0.000001 
  557.989     0.000001     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000001 
  561.023     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001 
  563.999     0.000001     0.000002     0.000001     0.000002     0.000002     0.000002     0.000001     0.000001 
  567.032     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  570.007     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 