# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       1.490000     1.490000     2.110000     2.110000     1.320000     1.320000     2.500000     2.500000 
# z_pos      56.000000    56.000000    57.000000    57.000000    55.000000    55.000000    58.000000    58.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       321          322          323          324          325          326          327          328      
#
# lambda for peak transmission
#          482.9050000  482.9050000  479.9160000  482.9050000  482.9050000  482.9050000  479.9160000  482.9050000 
# peak transmission
#            0.8270700    0.8443190    0.8588110    0.8411950    0.8146360    0.8431910    0.8761490    0.8393770 
# lambda blue with 1/2 of peak transmission
#          390.6888876  390.6969613  390.5744588  390.6839345  390.7621191  390.7538954  390.0813692  390.6469535 
# lambda red  with 1/2 of peak transmission
#          491.0069929  490.7242329  490.1281841  490.6273688  491.3575127  490.8227173  489.1222201  490.6064397 
# half width                              
#          100.3181053  100.0272716   99.5537253   99.9434343  100.5953936  100.0688219   99.0408510   99.9594863 
# central wavelength                      
#          440.8479402  440.7105971  440.3513214  440.6556517  441.0598159  440.7883064  439.6017947  440.6266966 
# central wavelength calculated as SAGEM (mean frequency)
#          435.1409144  435.0348457  434.7245958  434.9887040  435.3239538  435.1088402  434.0233995  434.9575559 
# lambda blue with 80% of peak transmission
#          405.8671629  404.6523260  403.5076042  404.7507054  410.7910711  405.0323225  402.7886357  405.1161915 
# lambda red  with 80% of peak transmission
#          488.8786672  488.3868356  487.5632159  488.2208556  489.1579558  488.5409568  486.7177122  488.1913105 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.7518277    0.7698859    0.7884071    0.7661830    0.7374385    0.7701738    0.8054448    0.7653209 
# ATB calculated from points above 50%
#            0.7270143    0.7482348    0.7645384    0.7440549    0.7085226    0.7452374    0.7783960    0.7394057 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 439.601795 at column =  8, at id = 327 
# maxCWL      = 441.059816 at column =  6, at id = 325 
# difference =    1.4580213 
# minBW       = 99.040851 at column =  8, at id = 327 
# maxBW       = 100.595394 at column =  6, at id = 325 
# difference =    1.5545427 
# minATB80    = 0.737438 at column =  6, at id = 325 
# maxATB80    = 0.805445 at column =  8, at id = 327 
# difference =    0.0680063 
# minBlueEdge = 390.081369 at column =  8, at id = 327 
# maxBlueEdge = 390.762119 at column =  6, at id = 325 
# difference =    0.6807499 
# minRedEdge  = 489.122220 at column =  8, at id = 327 
# maxRedEdge  = 491.357513 at column =  6, at id = 325 
# difference =    2.2352926 
# minABR      = 9.999900 at column =  2, at id = 321 
# maxABR      = 9.999900 at column =  2, at id = 321 
# difference =    0.0000000 
  359.715    -0.000007     0.000004    -0.000001     0.000004     0.000001     0.000011     0.000001    -0.000000 
  362.718    -0.000002     0.000004     0.000001     0.000003    -0.000001     0.000005     0.000000     0.000001 
  365.721    -0.000002    -0.000000    -0.000003    -0.000002    -0.000002     0.000001     0.000000    -0.000004 
  368.724    -0.000000     0.000004    -0.000001     0.000002     0.000003     0.000006     0.000000    -0.000001 
  371.726    -0.000001     0.000004    -0.000003     0.000001     0.000002     0.000002     0.000003    -0.000000 
  374.728    -0.000004     0.000004    -0.000003     0.000002     0.000003     0.000001     0.000004     0.000001 
  377.730     0.000001     0.000001    -0.000000     0.000005     0.000003     0.000004     0.000002     0.000002 
  380.788     0.000002     0.000005     0.000026     0.000006     0.000002     0.000005    -0.000000     0.000004 
  383.789     0.015944     0.015423     0.015455     0.015642     0.015099     0.013155     0.012422     0.016218 
  386.789     0.118613     0.115409     0.117003     0.115184     0.119833     0.112560     0.129784     0.117873 
  389.790     0.344608     0.345225     0.361167     0.346288     0.339316     0.339479     0.415466     0.351497 
  392.790     0.574649     0.599705     0.622131     0.595667     0.549173     0.595056     0.648248     0.590220 
  395.790     0.586121     0.613626     0.636352     0.608867     0.559314     0.609096     0.659787     0.601668 
  398.789     0.610213     0.637235     0.658493     0.632509     0.583796     0.632849     0.683564     0.626051 
  401.788     0.610995     0.638601     0.658245     0.632876     0.585053     0.634243     0.677308     0.624211 
  404.787     0.647415     0.677188     0.708479     0.673447     0.619117     0.671161     0.748073     0.667278 
  407.785     0.686941     0.718034     0.745819     0.713377     0.658621     0.712611     0.769322     0.705743 
  410.783     0.677616     0.705495     0.730512     0.701102     0.651635     0.700313     0.756499     0.694254 
  413.781     0.705346     0.734856     0.762856     0.730306     0.679048     0.729524     0.791778     0.724233 
  416.834     0.715859     0.744984     0.770275     0.740470     0.690263     0.739085     0.792045     0.733573 
  419.831     0.707858     0.736308     0.761752     0.731607     0.683588     0.731174     0.789220     0.725429 
  422.828     0.731140     0.758916     0.785558     0.755036     0.705552     0.752561     0.809369     0.748486 
  425.824     0.736689     0.763892     0.787528     0.759764     0.713713     0.759229     0.806129     0.753753 
  428.820     0.702030     0.727221     0.747031     0.722163     0.680758     0.722957     0.762361     0.715667 
  431.815     0.733582     0.758436     0.784189     0.755045     0.712773     0.754269     0.811893     0.750966 
  434.810     0.751610     0.776681     0.798702     0.772688     0.730677     0.772378     0.818884     0.767669 
  437.862     0.729074     0.752184     0.767957     0.747062     0.710473     0.748166     0.776441     0.740656 
  440.856     0.732663     0.752991     0.775438     0.749684     0.715304     0.751583     0.802713     0.747858 
  443.850     0.767309     0.788725     0.810582     0.785728     0.747420     0.784520     0.828808     0.781189 
  446.844     0.756971     0.778178     0.796991     0.774718     0.739856     0.775917     0.810290     0.768761 
  449.837     0.752239     0.772611     0.791852     0.769351     0.733488     0.770162     0.808158     0.764477 
  452.830     0.736640     0.755245     0.763670     0.750695     0.718903     0.753065     0.763011     0.744644 
  455.878     0.693452     0.706054     0.707224     0.701033     0.682008     0.706823     0.709232     0.699920 
  458.870     0.710010     0.721981     0.731588     0.719212     0.697697     0.720744     0.757715     0.720592 
  461.862     0.776351     0.792828     0.806280     0.790364     0.762667     0.791560     0.822808     0.788793 
  464.853     0.791309     0.808969     0.825477     0.806317     0.777279     0.807782     0.845942     0.804855 
  467.901     0.800068     0.818768     0.835233     0.816187     0.783870     0.815624     0.848314     0.811833 
  470.891     0.800988     0.820046     0.837207     0.817105     0.786392     0.817974     0.852773     0.813864 
  473.881     0.808527     0.826941     0.845775     0.825060     0.794757     0.825243     0.866867     0.822497 
  476.871     0.823012     0.841029     0.855530     0.838227     0.807768     0.836828     0.867152     0.833890 
  479.916     0.825764     0.843513     0.858811     0.840934     0.812181     0.841258     0.876149     0.838233 
  482.905     0.827070     0.844319     0.858303     0.841195     0.814636     0.843191     0.870365     0.839377 
  485.894     0.820165     0.831179     0.825725     0.826055     0.810928     0.831090     0.791307     0.823457 
  488.882     0.661479     0.644523     0.577486     0.629455     0.682370     0.654384     0.463427     0.625816 
  491.925     0.306422     0.277223     0.215895     0.265318     0.344265     0.289377     0.142273     0.262077 
  494.913     0.083244     0.072774     0.052968     0.068627     0.098120     0.076914     0.032534     0.067093 
  497.899     0.020054     0.017605     0.013211     0.016618     0.023688     0.018548     0.008974     0.016456 
  500.942     0.006626     0.005854     0.004466     0.005529     0.007766     0.006129     0.003148     0.005492 
  503.928     0.002562     0.002295     0.001776     0.002159     0.002955     0.002382     0.001283     0.002146 
  506.913     0.000986     0.000887     0.000692     0.000836     0.001126     0.000924     0.000498     0.000826 
  509.954     0.000448     0.000405     0.000331     0.000389     0.000504     0.000417     0.000260     0.000385 
  512.939     0.000255     0.000231     0.000180     0.000218     0.000289     0.000243     0.000144     0.000218 
  515.923     0.000136     0.000129     0.000100     0.000120     0.000154     0.000134     0.000079     0.000122 
  518.963     0.000068     0.000057     0.000052     0.000057     0.000079     0.000063     0.000037     0.000053 
  521.946     0.000037     0.000037     0.000029     0.000031     0.000045     0.000033     0.000024     0.000030 
  524.929     0.000026     0.000024     0.000023     0.000025     0.000032     0.000028     0.000013     0.000025 
  527.967     0.000018     0.000017     0.000015     0.000019     0.000019     0.000021     0.000015     0.000018 
  530.949     0.000017     0.000016     0.000013     0.000016     0.000018     0.000016     0.000001     0.000008 
  533.987     0.000007     0.000006    -0.000001     0.000001     0.000013     0.000007     0.000001     0.000001 
  536.968     0.000007     0.000006     0.000002     0.000005     0.000015     0.000003     0.000002     0.000003 
  539.948     0.000007     0.000001     0.000003     0.000004     0.000012     0.000007    -0.000001     0.000004 
  542.984     0.000006     0.000003     0.000002     0.000003     0.000011     0.000004     0.000001     0.000003 
  545.964     0.000006     0.000003     0.000001     0.000003    -0.000000     0.000003     0.000002     0.000002 
  548.999     0.000003     0.000003     0.000002     0.000002     0.000003     0.000002     0.000001     0.000002 
  551.977     0.000002     0.000002     0.000001     0.000002     0.000003     0.000002     0.000002     0.000002 
  555.012     0.000002     0.000002     0.000000     0.000002     0.000003     0.000002     0.000001     0.000002 
  557.989     0.000001     0.000002     0.000000     0.000001     0.000002     0.000001     0.000001     0.000001 
  561.023     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001 
  563.999     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001 
  567.032     0.000001     0.000002     0.000001     0.000001     0.000002    -0.000001     0.000001     0.000001 
  570.007     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001 