# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       1.490000     2.110000     2.110000     1.490000     1.320000     2.500000     2.500000     1.320000 
# z_pos      56.000000    57.000000    57.000000    56.000000    55.000000    58.000000    58.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       221          222          223          224          225          226          227          228      
#
# lambda for peak transmission
#          482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  479.9160000 
# peak transmission
#            0.7090406    0.7186607    0.7068977    0.6968462    0.7027117    0.7266773    0.7012806    0.6808408 
# lambda blue with 1/2 of peak transmission
#          386.6495621  386.7621950  386.6992674  386.4400542  386.6285131  386.6307017  386.7096148  386.3203210 
# lambda red  with 1/2 of peak transmission
#          491.1375321  491.1264184  491.0665678  490.7983717  490.9861115  490.5824025  490.8513483  490.3864215 
# half width                              
#          104.4879699  104.3642234  104.3673004  104.3583175  104.3575983  103.9517008  104.1417335  104.0661006 
# central wavelength                      
#          438.8935471  438.9443067  438.8829176  438.6192130  438.8073123  438.6065521  438.7804816  438.3533713 
# central wavelength calculated as SAGEM (mean frequency)
#          432.6746496  432.7408482  432.6782255  432.4118592  432.6027049  432.4472984  432.6011384  432.1769882 
# lambda blue with 80% of peak transmission
#          402.8467208  400.1403186  402.8707923  404.2944221  403.7949156  397.9939588  403.5746405  409.1310050 
# lambda red  with 80% of peak transmission
#          488.9009585  488.9099262  488.7671651  488.3513126  488.6477866  488.0852047  488.4154947  487.7375857 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.6564049    0.6668238    0.6575893    0.6454091    0.6514296    0.6772833    0.6502011    0.6324646 
# ATB calculated from points above 50%
#            0.6292139    0.6427011    0.6270524    0.6145726    0.6208147    0.6524310    0.6192542    0.5937188 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 438.353371 at column =  9, at id = 228 
# maxCWL      = 438.944307 at column =  3, at id = 222 
# difference =    0.5909355 
# minBW       = 103.951701 at column =  7, at id = 226 
# maxBW       = 104.487970 at column =  2, at id = 221 
# difference =    0.5362692 
# minATB80    = 0.632465 at column =  9, at id = 228 
# maxATB80    = 0.677283 at column =  7, at id = 226 
# difference =    0.0448188 
# minBlueEdge = 386.320321 at column =  9, at id = 228 
# maxBlueEdge = 386.762195 at column =  3, at id = 222 
# difference =    0.4418740 
# minRedEdge  = 490.386422 at column =  9, at id = 228 
# maxRedEdge  = 491.137532 at column =  2, at id = 221 
# difference =    0.7511105 
# minABR      = 9.999900 at column =  2, at id = 221 
# maxABR      = 9.999900 at column =  2, at id = 221 
# difference =    0.0000000 
  359.715     0.000004     0.000005     0.000003     0.000004     0.000003    -0.000001    -0.000001     0.000005 
  362.718     0.000004     0.000002    -0.000001     0.000005     0.000001    -0.000000     0.000001     0.000003 
  365.721     0.000004     0.000005    -0.000001     0.000001     0.000001    -0.000001    -0.000001     0.000003 
  368.724     0.000005     0.000003    -0.000001     0.000001    -0.000001    -0.000001     0.000003     0.000005 
  371.726     0.000004     0.000002     0.000001     0.000004    -0.000001    -0.000004     0.000001     0.000002 
  374.728     0.000002     0.000006     0.000002     0.000072     0.000004     0.000001     0.000023     0.000261 
  377.730     0.005128     0.003242     0.005230     0.008702     0.006115     0.003624     0.006039     0.013531 
  380.788     0.045899     0.037550     0.045606     0.062854     0.051038     0.041209     0.049949     0.087463 
  383.789     0.206128     0.184323     0.203319     0.235864     0.215752     0.198394     0.211289     0.256850 
  386.789     0.361754     0.360908     0.358078     0.363239     0.359020     0.372527     0.354428     0.355894 
  389.790     0.462179     0.469186     0.459559     0.455248     0.456692     0.487793     0.454851     0.436907 
  392.790     0.515621     0.535110     0.513854     0.496021     0.505131     0.550661     0.504487     0.468413 
  395.790     0.533769     0.552801     0.531908     0.515330     0.523344     0.568996     0.523091     0.490332 
  398.789     0.551576     0.571106     0.550166     0.531299     0.540701     0.585795     0.540525     0.501864 
  401.788     0.561000     0.579590     0.558901     0.543338     0.550524     0.595780     0.550540     0.519686 
  404.787     0.578654     0.597971     0.577228     0.560256     0.567926     0.612614     0.568139     0.535666 
  407.785     0.586074     0.605109     0.584597     0.566651     0.575520     0.619207     0.575242     0.540218 
  410.783     0.590588     0.608576     0.588287     0.572496     0.580521     0.622790     0.579695     0.550140 
  413.781     0.600361     0.617009     0.598536     0.585177     0.591679     0.630508     0.590577     0.567477 
  416.834     0.621863     0.638452     0.620221     0.605826     0.612257     0.651865     0.612208     0.583139 
  419.831     0.634422     0.651552     0.632161     0.617663     0.624360     0.664987     0.624219     0.597127 
  422.828     0.638109     0.654460     0.636089     0.622268     0.628572     0.666473     0.628469     0.601764 
  425.824     0.641755     0.657752     0.640135     0.624992     0.631923     0.670276     0.631961     0.602721 
  428.820     0.643977     0.659654     0.642359     0.629228     0.635247     0.671233     0.634332     0.611712 
  431.815     0.648206     0.663295     0.646958     0.633772     0.639648     0.675200     0.639073     0.614001 
  434.810     0.646588     0.663055     0.644713     0.628641     0.637200     0.672881     0.635430     0.607893 
  437.862     0.646056     0.656385     0.644056     0.637619     0.639949     0.668112     0.637774     0.624527 
  440.856     0.666355     0.679880     0.665880     0.653110     0.658808     0.691031     0.657798     0.633585 
  443.850     0.663657     0.678989     0.662079     0.647016     0.654833     0.687007     0.652568     0.625559 
  446.844     0.650816     0.662987     0.648750     0.639778     0.643668     0.672373     0.641646     0.625697 
  449.837     0.677558     0.688900     0.676192     0.667106     0.671037     0.700556     0.670287     0.648836 
  452.830     0.684474     0.697170     0.682814     0.671424     0.677092     0.706532     0.676464     0.648659 
  455.878     0.684140     0.698259     0.682326     0.667820     0.675882     0.708084     0.674974     0.640858 
  458.870     0.685866     0.697924     0.683742     0.674975     0.679353     0.708070     0.677262     0.658763 
  461.862     0.694112     0.704703     0.692454     0.683344     0.687331     0.713525     0.686096     0.667013 
  464.853     0.694411     0.705517     0.692428     0.681496     0.687186     0.714176     0.685362     0.663720 
  467.901     0.691146     0.702523     0.689217     0.678721     0.684438     0.710984     0.682233     0.660728 
  470.891     0.692302     0.702346     0.690246     0.682325     0.685720     0.711657     0.684410     0.668748 
  473.881     0.704074     0.714292     0.701975     0.691386     0.697224     0.722285     0.696096     0.671857 
  476.871     0.694608     0.704224     0.691756     0.684667     0.687986     0.711307     0.686037     0.671602 
  479.916     0.702977     0.710492     0.700230     0.694613     0.696996     0.718490     0.695646     0.680841 
  482.905     0.709041     0.718661     0.706898     0.696846     0.702712     0.726677     0.701281     0.676912 
  485.894     0.694167     0.706915     0.690285     0.672225     0.685031     0.707866     0.680416     0.640477 
  488.882     0.569036     0.577645     0.560531     0.532696     0.551720     0.535333     0.538936     0.485202 
  491.925     0.279627     0.281652     0.272075     0.240090     0.261950     0.227536     0.247985     0.192352 
  494.913     0.070248     0.071747     0.067431     0.056511     0.063967     0.053192     0.059188     0.043654 
  497.899     0.016531     0.016094     0.015813     0.014645     0.015661     0.012476     0.014394     0.012862 
  500.942     0.005805     0.005552     0.005528     0.005140     0.005530     0.004396     0.005055     0.004364 
  503.928     0.002062     0.002026     0.001954     0.001737     0.001924     0.001602     0.001750     0.001389 
  506.913     0.000710     0.000672     0.000674     0.000677     0.000689     0.000551     0.000633     0.000656 
  509.954     0.000370     0.000348     0.000352     0.000344     0.000362     0.000282     0.000328     0.000322 
  512.939     0.000183     0.000169     0.000172     0.000167     0.000181     0.000143     0.000163     0.000149 
  515.923     0.000078     0.000076     0.000075     0.000071     0.000075     0.000062     0.000070     0.000067 
  518.963     0.000042     0.000036     0.000040     0.000040     0.000037     0.000028     0.000035     0.000040 
  521.946     0.000031     0.000022     0.000028     0.000030     0.000025     0.000020     0.000023     0.000028 
  524.929     0.000015     0.000018     0.000017     0.000018     0.000016     0.000014     0.000018     0.000015 
  527.967     0.000015     0.000008     0.000013     0.000013     0.000014     0.000014     0.000014     0.000014 
  530.949     0.000006     0.000007     0.000010     0.000006     0.000008     0.000012     0.000006     0.000013 
  533.987     0.000011     0.000004     0.000011     0.000011     0.000006     0.000006     0.000002     0.000007 
  536.968     0.000005     0.000005     0.000001     0.000001     0.000000    -0.000000     0.000002     0.000005 
  539.948     0.000001     0.000001     0.000002     0.000001     0.000002     0.000001     0.000002     0.000003 
  542.984     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002 
  545.964     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002 
  548.999     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002 
  551.977     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002 
  555.012     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001 
  557.989     0.000002     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002 
  561.023     0.000001     0.000002     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001 
  563.999     0.000001     0.000002     0.000002     0.000001     0.000002     0.000000     0.000001     0.000001 
  567.032     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  570.007     0.000001     0.000002     0.000001     0.000002     0.000001     0.000000     0.000001     0.000001 