# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       1.490000     2.110000     2.110000     1.490000     1.320000     2.500000     2.500000     1.320000 
# z_pos      56.000000    57.000000    57.000000    56.000000    55.000000    58.000000    58.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       221          222          223          224          225          226          227          228      
#
# lambda for peak transmission
#          482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  479.9160000 
# peak transmission
#            0.8596120    0.8712750    0.8570140    0.8448280    0.8519390    0.8809940    0.8502040    0.8242290 
# lambda blue with 1/2 of peak transmission
#          385.9653355  386.1543089  386.0140887  385.6091773  385.8900001  386.0051102  385.9735157  385.2496485 
# lambda red  with 1/2 of peak transmission
#          491.1515868  491.1403110  491.0804487  490.8112207  490.9996436  490.5946907  490.8644824  490.4032605 
# half width                              
#          105.1862514  104.9860020  105.0663600  105.2020433  105.1096435  104.5895805  104.8909668  105.1536120 
# central wavelength                      
#          438.5584611  438.6473100  438.5472687  438.2101990  438.4448219  438.2999005  438.4189991  437.8264545 
# central wavelength calculated as SAGEM (mean frequency)
#          432.2513502  432.3654633  432.2543666  431.8961801  432.1452623  432.0604624  432.1452547  431.5127188 
# lambda blue with 80% of peak transmission
#          394.3253826  392.5003453  394.3792885  396.6632159  395.6615825  391.9833643  395.4839818  400.9379005 
# lambda red  with 80% of peak transmission
#          488.9182978  488.9271219  488.8043124  488.3824232  488.6828235  488.1097892  488.4468008  487.7764753 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.7872709    0.8013331    0.7880073    0.7758760    0.7801514    0.8179437    0.7787930    0.7548731 
# ATB calculated from points above 50%
#            0.7706783    0.7872589    0.7680175    0.7527017    0.7603525    0.7993247    0.7584366    0.7270466 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 437.826455 at column =  9, at id = 228 
# maxCWL      = 438.647310 at column =  3, at id = 222 
# difference =    0.8208555 
# minBW       = 104.589580 at column =  7, at id = 226 
# maxBW       = 105.202043 at column =  5, at id = 224 
# difference =    0.6124628 
# minATB80    = 0.754873 at column =  9, at id = 228 
# maxATB80    = 0.817944 at column =  7, at id = 226 
# difference =    0.0630706 
# minBlueEdge = 385.249649 at column =  9, at id = 228 
# maxBlueEdge = 386.154309 at column =  3, at id = 222 
# difference =    0.9046604 
# minRedEdge  = 490.403260 at column =  9, at id = 228 
# maxRedEdge  = 491.151587 at column =  2, at id = 221 
# difference =    0.7483263 
# minABR      = 9.999900 at column =  2, at id = 221 
# maxABR      = 9.999900 at column =  2, at id = 221 
# difference =    0.0000000 
  359.715     0.000006     0.000008     0.000005     0.000006     0.000005    -0.000001    -0.000002     0.000008 
  362.718     0.000006     0.000003    -0.000002     0.000007     0.000002    -0.000000     0.000002     0.000005 
  365.721     0.000006     0.000007    -0.000001     0.000001     0.000002    -0.000001    -0.000001     0.000004 
  368.724     0.000007     0.000004    -0.000002     0.000002    -0.000001    -0.000001     0.000004     0.000007 
  371.726     0.000005     0.000003     0.000001     0.000005    -0.000002    -0.000005     0.000002     0.000003 
  374.728     0.000003     0.000008     0.000003     0.000101     0.000006     0.000001     0.000032     0.000367 
  377.730     0.007121     0.004502     0.007263     0.012085     0.008492     0.005032     0.008386     0.018791 
  380.788     0.063044     0.051576     0.062641     0.086332     0.070103     0.056602     0.068607     0.120134 
  383.789     0.280122     0.250489     0.276305     0.320532     0.293201     0.269612     0.287136     0.349051 
  386.789     0.486456     0.485319     0.481513     0.488453     0.482780     0.500943     0.476605     0.478576 
  389.790     0.615046     0.624371     0.611560     0.605823     0.607744     0.649132     0.605294     0.581415 
  392.790     0.679115     0.704784     0.676788     0.653300     0.665299     0.725266     0.664451     0.616939 
  395.790     0.695869     0.720681     0.693443     0.671830     0.682278     0.741794     0.681948     0.639241 
  398.789     0.711847     0.737052     0.710028     0.685679     0.697813     0.756010     0.697586     0.647690 
  401.788     0.716797     0.740549     0.714115     0.694230     0.703411     0.761236     0.703432     0.664009 
  404.787     0.732060     0.756498     0.730256     0.708784     0.718488     0.775023     0.718757     0.677675 
  407.785     0.734207     0.758053     0.732357     0.709875     0.720985     0.775714     0.720637     0.676761 
  410.783     0.732707     0.755023     0.729852     0.710261     0.720218     0.772658     0.719193     0.682525 
  413.781     0.737698     0.758154     0.735455     0.719040     0.727030     0.774741     0.725676     0.697291 
  416.834     0.756738     0.776924     0.754739     0.737222     0.745048     0.793247     0.744989     0.709615 
  419.831     0.764769     0.785418     0.762043     0.744566     0.752639     0.801613     0.752469     0.719811 
  422.828     0.768806     0.788506     0.766372     0.749721     0.757316     0.802979     0.757191     0.725017 
  425.824     0.773199     0.792472     0.771247     0.753003     0.761353     0.807562     0.761399     0.726170 
  428.820     0.775876     0.794764     0.773926     0.758106     0.765358     0.808714     0.764255     0.737002 
  431.815     0.780971     0.799151     0.779468     0.763581     0.770660     0.813494     0.769968     0.739760 
  434.810     0.779022     0.798862     0.776763     0.757399     0.767711     0.810700     0.765578     0.732401 
  437.862     0.778381     0.790825     0.775971     0.768216     0.771023     0.804954     0.768402     0.752442 
  440.856     0.802837     0.819133     0.802265     0.786880     0.793745     0.832568     0.792528     0.763356 
  443.850     0.799587     0.818059     0.797685     0.779537     0.788955     0.827719     0.786226     0.753685 
  446.844     0.784116     0.798780     0.781626     0.770817     0.775504     0.810088     0.773067     0.753852 
  449.837     0.816335     0.830000     0.814689     0.803742     0.808478     0.844043     0.807575     0.781730 
  452.830     0.824667     0.839964     0.822668     0.808945     0.815774     0.851243     0.815017     0.781517 
  455.878     0.824265     0.841276     0.822080     0.804603     0.814316     0.853113     0.813222     0.772118 
  458.870     0.826344     0.840872     0.823785     0.813223     0.818497     0.853096     0.815978     0.793690 
  461.862     0.836279     0.849040     0.834282     0.823306     0.828110     0.859669     0.826622     0.803630 
  464.853     0.836640     0.850021     0.834251     0.821079     0.827935     0.860453     0.825737     0.799663 
  467.901     0.832706     0.846413     0.830382     0.817736     0.824624     0.856607     0.821968     0.796058 
  470.891     0.834457     0.846563     0.831979     0.822432     0.826523     0.857786     0.824945     0.806067 
  473.881     0.849871     0.862205     0.847338     0.834556     0.841603     0.871854     0.840242     0.810983 
  476.871     0.839657     0.851282     0.836210     0.827641     0.831653     0.859844     0.829297     0.811847 
  479.916     0.851027     0.860125     0.847701     0.840902     0.843786     0.869807     0.842152     0.824229 
  482.905     0.859612     0.871275     0.857014     0.844828     0.851939     0.880994     0.850204     0.820660 
  485.894     0.842802     0.858279     0.838088     0.816161     0.831709     0.859434     0.826106     0.777615 
  488.882     0.691881     0.702349     0.681541     0.647696     0.670827     0.650903     0.655283     0.589949 
  491.925     0.340498     0.342964     0.331302     0.292354     0.318973     0.277067     0.301968     0.234224 
  494.913     0.085665     0.087493     0.082230     0.068913     0.078005     0.064866     0.072177     0.053234 
  497.899     0.020188     0.019655     0.019311     0.017885     0.019126     0.015236     0.017578     0.015708 
  500.942     0.007100     0.006791     0.006761     0.006287     0.006764     0.005377     0.006182     0.005337 
  503.928     0.002526     0.002481     0.002393     0.002127     0.002357     0.001962     0.002143     0.001701 
  506.913     0.000871     0.000824     0.000827     0.000831     0.000845     0.000676     0.000776     0.000805 
  509.954     0.000454     0.000427     0.000433     0.000423     0.000445     0.000347     0.000403     0.000395 
  512.939     0.000225     0.000208     0.000211     0.000206     0.000223     0.000176     0.000201     0.000183 
  515.923     0.000096     0.000094     0.000093     0.000088     0.000093     0.000076     0.000086     0.000082 
  518.963     0.000052     0.000045     0.000049     0.000049     0.000046     0.000035     0.000043     0.000049 
  521.946     0.000038     0.000027     0.000035     0.000037     0.000031     0.000025     0.000029     0.000035 
  524.929     0.000019     0.000022     0.000021     0.000022     0.000020     0.000017     0.000022     0.000019 
  527.967     0.000019     0.000010     0.000016     0.000016     0.000017     0.000017     0.000017     0.000018 
  530.949     0.000008     0.000009     0.000013     0.000008     0.000010     0.000015     0.000008     0.000016 
  533.987     0.000014     0.000005     0.000014     0.000014     0.000007     0.000007     0.000003     0.000009 
  536.968     0.000006     0.000006     0.000001     0.000001     0.000000    -0.000000     0.000002     0.000006 
  539.948     0.000001     0.000001     0.000003     0.000001     0.000003     0.000001     0.000002     0.000004 
  542.984     0.000002     0.000003     0.000003     0.000002     0.000003     0.000002     0.000003     0.000003 
  545.964     0.000002     0.000003     0.000003     0.000003     0.000003     0.000001     0.000002     0.000003 
  548.999     0.000002     0.000003     0.000003     0.000002     0.000002     0.000001     0.000002     0.000002 
  551.977     0.000001     0.000003     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002 
  555.012     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001 
  557.989     0.000002     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002 
  561.023     0.000001     0.000002     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001 
  563.999     0.000001     0.000002     0.000002     0.000001     0.000002     0.000000     0.000001     0.000001 
  567.032     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  570.007     0.000001     0.000002     0.000001     0.000002     0.000001     0.000000     0.000001     0.000001 