# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     2.110000     1.490000     1.490000     2.500000     2.500000     1.320000     1.320000 
# z_pos      57.000000    57.000000    56.000000    56.000000    58.000000    58.000000    55.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       121          122          123          124          125          126          127          128      
#
# lambda for peak transmission
#          482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  479.9160000  482.9050000  482.9050000 
# peak transmission
#            0.8661130    0.8447490    0.8593960    0.8826720    0.8651990    0.8206370    0.8516320    0.8933400 
# lambda blue with 1/2 of peak transmission
#          385.9502542  385.6876803  385.9640877  386.0744859  385.9023472  385.1762994  385.9146102  386.0102492 
# lambda red  with 1/2 of peak transmission
#          491.3316890  490.8896511  491.3258462  491.4330884  491.2249554  490.0577174  491.1770003  491.1005386 
# half width                              
#          105.3814348  105.2019708  105.3617585  105.3586025  105.3226082  104.8814180  105.2623901  105.0902894 
# central wavelength                      
#          438.6409716  438.2886657  438.6449670  438.7537871  438.5636513  437.6170084  438.5458053  438.5553939 
# central wavelength calculated as SAGEM (mean frequency)
#          432.3116228  431.9757859  432.3180392  432.4288075  432.2402523  431.3329109  432.2293780  432.2597416 
# lambda blue with 80% of peak transmission
#          392.7756661  396.6282905  394.0295961  392.1793808  393.0993133  401.5489827  395.9473618  391.5993410 
# lambda red  with 80% of peak transmission
#          489.0360526  488.4724125  489.0429361  489.1502060  488.9569096  487.3377924  488.9323370  488.8987597 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.7940628    0.7755244    0.7882461    0.8166109    0.7951221    0.7487559    0.7795673    0.8316362 
# ATB calculated from points above 50%
#            0.7806561    0.7524570    0.7716438    0.8025530    0.7787237    0.7199267    0.7599398    0.8177422 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 437.617008 at column =  7, at id = 126 
# maxCWL      = 438.753787 at column =  5, at id = 124 
# difference =    1.1367787 
# minBW       = 104.881418 at column =  7, at id = 126 
# maxBW       = 105.381435 at column =  2, at id = 121 
# difference =    0.5000168 
# minATB80    = 0.748756 at column =  7, at id = 126 
# maxATB80    = 0.831636 at column =  9, at id = 128 
# difference =    0.0828803 
# minBlueEdge = 385.176299 at column =  7, at id = 126 
# maxBlueEdge = 386.074486 at column =  5, at id = 124 
# difference =    0.8981865 
# minRedEdge  = 490.057717 at column =  7, at id = 126 
# maxRedEdge  = 491.433088 at column =  5, at id = 124 
# difference =    1.3753710 
# minABR      = 9.999900 at column =  2, at id = 121 
# maxABR      = 9.999900 at column =  2, at id = 121 
# difference =    0.0000000 
  359.715     0.000011     0.000007     0.000008     0.000006     0.000003     0.000006    -0.000008     0.000003 
  362.718     0.000011     0.000001     0.000007     0.000002     0.000004     0.000005    -0.000000     0.000001 
  365.721     0.000010     0.000003     0.000005     0.000003    -0.000002     0.000006    -0.000001     0.000002 
  368.724     0.000008     0.000001     0.000002    -0.000001    -0.000000     0.000003    -0.000001     0.000007 
  371.726     0.000011     0.000005     0.000004     0.000003    -0.000001     0.000005    -0.000000     0.000004 
  374.728     0.000010     0.000105     0.000002     0.000004     0.000004     0.000487     0.000006     0.000003 
  377.730     0.007024     0.011662     0.006882     0.004109     0.007759     0.020824     0.008232     0.003859 
  380.788     0.061509     0.082665     0.061498     0.050724     0.064364     0.128229     0.067830     0.050974 
  383.789     0.275795     0.313270     0.275957     0.250744     0.284761     0.352925     0.288802     0.254837 
  386.789     0.494087     0.485660     0.488005     0.500921     0.494625     0.477037     0.482178     0.513925 
  389.790     0.624445     0.604374     0.614553     0.639896     0.625863     0.578329     0.604090     0.662683 
  392.790     0.693219     0.653729     0.680642     0.723066     0.690482     0.609104     0.664058     0.748884 
  395.790     0.709004     0.672093     0.697280     0.738400     0.706749     0.632767     0.680433     0.763826 
  398.789     0.726522     0.685352     0.713557     0.755466     0.723480     0.639265     0.697063     0.779042 
  401.788     0.728831     0.693226     0.717803     0.758488     0.727076     0.658003     0.701853     0.782454 
  404.787     0.744599     0.707352     0.732519     0.773696     0.742385     0.668882     0.717185     0.796287 
  407.785     0.746738     0.709698     0.735507     0.775782     0.744316     0.668712     0.719952     0.797034 
  410.783     0.743814     0.710311     0.733872     0.772104     0.742060     0.675011     0.719745     0.793442 
  413.781     0.749195     0.718776     0.738803     0.774765     0.747085     0.690509     0.725469     0.794299 
  416.834     0.768016     0.736980     0.757448     0.792600     0.766490     0.702696     0.744497     0.811495 
  419.831     0.775148     0.744689     0.765157     0.800423     0.773491     0.713241     0.751975     0.819693 
  422.828     0.779678     0.749378     0.769699     0.803148     0.777913     0.717605     0.756640     0.821034 
  425.824     0.783592     0.752528     0.773668     0.807015     0.781274     0.719925     0.761383     0.824830 
  428.820     0.786276     0.757908     0.776249     0.808781     0.783946     0.729883     0.764385     0.826614 
  431.815     0.791294     0.763128     0.781633     0.813069     0.788986     0.732760     0.769327     0.829993 
  434.810     0.789702     0.757648     0.779792     0.814212     0.786475     0.724149     0.767025     0.830066 
  437.862     0.786630     0.767220     0.777732     0.804494     0.786262     0.747885     0.768215     0.820303 
  440.856     0.812446     0.787084     0.802941     0.831972     0.810446     0.757446     0.791962     0.847092 
  443.850     0.809843     0.780322     0.800741     0.832790     0.807192     0.744771     0.788677     0.847033 
  446.844     0.793029     0.770417     0.784711     0.814068     0.790914     0.751841     0.774241     0.826987 
  449.837     0.823967     0.802931     0.815803     0.842523     0.823654     0.776962     0.806776     0.856550 
  452.830     0.833902     0.808326     0.824523     0.853567     0.831932     0.776326     0.814627     0.865132 
  455.878     0.834053     0.804439     0.824950     0.855911     0.831369     0.770653     0.814084     0.867298 
  458.870     0.835010     0.812324     0.826774     0.854583     0.833244     0.790421     0.816668     0.866917 
  461.862     0.844469     0.822019     0.836620     0.861763     0.843333     0.797663     0.826868     0.873615 
  464.853     0.844531     0.820271     0.836582     0.862922     0.842980     0.792808     0.826995     0.875034 
  467.901     0.841074     0.817216     0.833333     0.859858     0.839355     0.790191     0.824007     0.871974 
  470.891     0.841536     0.821472     0.834310     0.859436     0.840336     0.804077     0.825982     0.872155 
  473.881     0.856931     0.834715     0.849997     0.873586     0.855869     0.805394     0.841543     0.885077 
  476.871     0.846496     0.826996     0.840069     0.864156     0.845180     0.808749     0.832011     0.874930 
  479.916     0.856975     0.840370     0.851018     0.871928     0.856954     0.820637     0.843531     0.882387 
  482.905     0.866113     0.844749     0.859396     0.882672     0.865199     0.815978     0.851632     0.893340 
  485.894     0.850443     0.817693     0.845144     0.873139     0.846572     0.760467     0.834680     0.881810 
  488.882     0.710327     0.653259     0.705692     0.737248     0.700732     0.545322     0.687035     0.716712 
  491.925     0.365902     0.303307     0.362033     0.384277     0.352485     0.195905     0.340678     0.346316 
  494.913     0.095576     0.073090     0.094520     0.103873     0.090152     0.043725     0.086373     0.088878 
  497.899     0.022242     0.018693     0.022109     0.023243     0.021485     0.013529     0.020911     0.020123 
  500.942     0.007710     0.006560     0.007726     0.007949     0.007487     0.004580     0.007374     0.006962 
  503.928     0.002733     0.002224     0.002758     0.002929     0.002626     0.001457     0.002596     0.002583 
  506.913     0.000933     0.000856     0.000931     0.000955     0.000917     0.000723     0.000905     0.000859 
  509.954     0.000493     0.000440     0.000487     0.000495     0.000479     0.000347     0.000474     0.000441 
  512.939     0.000242     0.000210     0.000241     0.000241     0.000236     0.000156     0.000233     0.000221 
  515.923     0.000104     0.000090     0.000103     0.000106     0.000100     0.000075     0.000101     0.000098 
  518.963     0.000052     0.000048     0.000051     0.000053     0.000056     0.000047     0.000053     0.000045 
  521.946     0.000038     0.000035     0.000040     0.000035     0.000040     0.000031     0.000034     0.000035 
  524.929     0.000025     0.000022     0.000027     0.000027     0.000023     0.000019     0.000024     0.000024 
  527.967     0.000016     0.000019     0.000019     0.000016     0.000018     0.000018     0.000018     0.000018 
  530.949     0.000014     0.000015     0.000003     0.000015     0.000003     0.000016     0.000014     0.000007 
  533.987     0.000015     0.000017     0.000011     0.000008     0.000017     0.000003     0.000014     0.000015 
  536.968     0.000002     0.000013     0.000010     0.000001     0.000002     0.000006     0.000001     0.000008 
  539.948     0.000003     0.000003     0.000007     0.000002     0.000003     0.000005     0.000003     0.000003 
  542.984     0.000003     0.000003     0.000007     0.000003     0.000003     0.000004     0.000002     0.000003 
  545.964     0.000003     0.000003     0.000001     0.000002     0.000003     0.000004     0.000002     0.000002 
  548.999     0.000003     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002 
  551.977     0.000002     0.000002     0.000002     0.000001     0.000001     0.000002     0.000002     0.000002 
  555.012     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001 
  557.989     0.000001     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002 
  561.023     0.000002     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000002 
  563.999     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002 
  567.032     0.000002     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002 
  570.007     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000002 