# number of points on sci filter + aux + bad z = 2
# number of points on sci filter               = 2
# number of positions in lambda                = 301
# noof scans  1            1          
# x_pos     162.640000  -162.640000 
# y_pos       0.000000     0.000000 
# angle       2.960000     2.960000 
# z_pos      10.000000    10.000000 
# r_pos     162.640000   162.640000 
# phi         0.000000     3.141593 
# gnupl col      2            3      
# pos_id        49           50      
#
# lambda for peak transmission
#          479.9160000  479.9160000 
# peak transmission
#            0.6528639    0.6493491 
# lambda blue with 1/2 of peak transmission
#          387.2015267  387.1947910 
# lambda red  with 1/2 of peak transmission
#          489.9755993  489.7638657 
# half width                              
#          102.7740726  102.5690747 
# central wavelength                      
#          438.5885630  438.4793283 
# central wavelength calculated as SAGEM (mean frequency)
#          432.5678235  432.4810894 
# lambda blue with 80% of peak transmission
#          413.5373949  413.2773074 
# lambda red  with 80% of peak transmission
#          487.2192612  487.0157629 
# lambda blue with 0.0001 of peak transmission
#          372.4492880  372.2375365 
# lambda red  with 0.0001 of peak transmission
#          515.7043423  515.0210420 
# ATB calculated from points above 80%
#            0.5999660    0.5967384 
# ATB calculated from points above 50%
#            0.5612301    0.5577588 
# ABR calculated from points below and above 0.0001
#           -0.0000003    0.0000140 
# minCWL      = 438.479328 at column =  3, at id = 50 
# maxCWL      = 438.588563 at column =  2, at id = 49 
# difference =    0.1092347 
# minBW       = 102.569075 at column =  3, at id = 50 
# maxBW       = 102.774073 at column =  2, at id = 49 
# difference =    0.2049980 
# minATB80    = 0.596738 at column =  3, at id = 50 
# maxATB80    = 0.599966 at column =  2, at id = 49 
# difference =    0.0032276 
# minBlueEdge = 387.194791 at column =  3, at id = 50 
# maxBlueEdge = 387.201527 at column =  2, at id = 49 
# difference =    0.0067357 
# minRedEdge  = 489.763866 at column =  3, at id = 50 
# maxRedEdge  = 489.975599 at column =  2, at id = 49 
# difference =    0.2117337 
# minABR      = -0.000000 at column =  2, at id = 49 
# maxABR      = 0.000014 at column =  3, at id = 50 
# difference =    0.0000143 
  299.645    -0.000227     0.000056 
  302.654    -0.000106    -0.000059 
  305.662    -0.000053    -0.000038 
  308.671    -0.000043    -0.000005 
  311.679    -0.000021    -0.000025 
  314.687    -0.000037    -0.000003 
  317.694    -0.000014     0.000000 
  320.702    -0.000007     0.000005 
  323.709     0.000010     0.000006 
  326.716     0.000005     0.000009 
  329.665     0.000004    -0.000003 
  332.672     0.000009    -0.000004 
  335.678    -0.000005    -0.000005 
  338.683     0.000005    -0.000001 
  341.689     0.000006    -0.000006 
  344.694    -0.000001     0.000000 
  347.699     0.000001     0.000000 
  350.703    -0.000000    -0.000003 
  353.707    -0.000000    -0.000001 
  356.711     0.000001     0.000002 
  359.715    -0.000000     0.000000 
  362.718    -0.000001     0.000000 
  365.721    -0.000001     0.000002 
  368.724    -0.000001     0.000001 
  371.726    -0.000004     0.000000 
  374.728     0.000282     0.000381 
  377.730     0.013370     0.014244 
  380.788     0.087010     0.089525 
  383.789     0.233286     0.233233 
  386.789     0.316485     0.314851 
  389.790     0.388848     0.387502 
  392.790     0.417614     0.415308 
  395.790     0.440342     0.438722 
  398.789     0.450961     0.447515 
  401.788     0.471816     0.470935 
  404.787     0.487935     0.486506 
  407.785     0.492956     0.490462 
  410.783     0.505276     0.503245 
  413.781     0.523796     0.522758 
  416.834     0.537840     0.535931 
  419.831     0.553498     0.552453 
  422.828     0.558779     0.556767 
  425.824     0.560613     0.558765 
  428.820     0.571428     0.569902 
  431.815     0.575019     0.572857 
  434.810     0.569729     0.566080 
  437.862     0.588702     0.586785 
  440.856     0.596738     0.593855 
  443.850     0.588221     0.583193 
  446.844     0.593228     0.590528 
  449.837     0.613210     0.610067 
  452.830     0.610971     0.605919 
  455.878     0.606552     0.602553 
  458.870     0.627092     0.624870 
  461.862     0.635358     0.633102 
  464.853     0.632544     0.628911 
  467.901     0.629207     0.625357 
  470.891     0.640485     0.637868 
  473.881     0.642184     0.637386 
  476.871     0.643802     0.641123 
  479.916     0.652864     0.649349 
  482.905     0.647800     0.643004 
  485.894     0.599972     0.589511 
  488.882     0.424829     0.402970 
  491.925     0.151033     0.132802 
  494.913     0.034109     0.029457 
  497.899     0.010623     0.009419 
  500.942     0.003570     0.003135 
  503.928     0.001138     0.000996 
  506.913     0.000565     0.000513 
  509.954     0.000269     0.000245 
  512.939     0.000121     0.000102 
  515.923     0.000061     0.000049 
  518.963     0.000038     0.000033 
  521.946     0.000029     0.000026 
  524.929     0.000017     0.000011 
  527.967     0.000014     0.000012 
  530.949     0.000013     0.000010 
  533.987     0.000011     0.000000 
  536.968     0.000003     0.000002 
  539.948     0.000004     0.000002 
  542.984     0.000004     0.000002 
  545.964     0.000003     0.000001 
  548.999     0.000002     0.000001 
  551.977     0.000002     0.000000 
  555.012     0.000001     0.000001 
  557.989     0.000001     0.000000 
  561.023     0.000002     0.000001 
  563.999     0.000001     0.000000 
  567.032     0.000001     0.000000 
  570.007     0.000001     0.000000 
  573.038     0.000000    -0.000000 
  576.013     0.000001    -0.000000 
  579.043    -0.000000    -0.000001 
  582.017    -0.000000    -0.000001 
  585.046     0.000000    -0.000001 
  588.019     0.000000    -0.000001 
  591.047     0.000000    -0.000001 
  594.019     0.000000    -0.000001 
  597.046    -0.000000    -0.000001 
  600.073    -0.000000    -0.000001 
  603.043    -0.000000    -0.000001 
  606.068     0.000000    -0.000000 
  609.038     0.000000    -0.000001 
  612.062    -0.000000    -0.000000 
  615.086    -0.000000    -0.000001 
  618.053     0.000000    -0.000001 
  621.076    -0.000000    -0.000001 
  624.099     0.000001    -0.000000 
  627.064     0.000001    -0.000000 
  630.086     0.000001    -0.000000 
  633.106     0.000000    -0.000000 
  636.071     0.000001    -0.000000 
  639.090     0.000000    -0.000000 
  642.109     0.000000    -0.000000 
  645.128    -0.000000    -0.000001 
  648.090    -0.000000    -0.000000 
  651.107    -0.000000    -0.000000 
  654.123     0.000001     0.000000 
  657.139    -0.000000    -0.000000 
  660.099     0.000000    -0.000000 
  663.114    -0.000001    -0.000001 
  666.129     0.000000    -0.000001 
  669.142     0.000000     0.000000 
  672.155     0.000001     0.000001 
  675.168     0.000000    -0.000001 
  678.124     0.000000    -0.000000 
  681.136     0.000000    -0.000001 
  684.146    -0.000000    -0.000001 
  687.157     0.000000    -0.000001 
  690.166     0.000000    -0.000001 
  693.175     0.000021     0.000026 
  696.183     0.000085     0.000072 
  699.191     0.000000    -0.000001 
  702.198     0.000000    -0.000000 
  705.205    -0.000000     0.000000 
  708.211    -0.000001     0.000000 
  711.216     0.000002     0.000006 
  714.220     0.000001     0.000001 
  717.224     0.000001    -0.000000 
  720.228    -0.000000    -0.000001 
  723.230    -0.000000    -0.000000 
  726.232    -0.000000    -0.000001 
  729.234    -0.000000    -0.000001 
  732.234    -0.000000    -0.000001 
  735.235    -0.000000    -0.000001 
  738.234     0.000000    -0.000001 
  741.233     0.000001    -0.000001 
  744.231     0.000000    -0.000001 
  747.228    -0.000001    -0.000001 
  750.225    -0.000000    -0.000001 
  753.221     0.000000    -0.000001 
  756.272     0.000001    -0.000001 
  759.267     0.000001     0.000001 
  762.261     0.000032     0.000029 
  765.254     0.000016     0.000007 
  768.247    -0.000001     0.000002 
  771.294     0.000031     0.000028 
  774.286     0.000020     0.000008 
  777.277     0.000001    -0.000001 
  780.266     0.000001    -0.000001 
  783.311    -0.000001    -0.000001 
  786.300     0.000001    -0.000001 
  789.288     0.000001    -0.000001 
  792.275     0.000015     0.000013 
  795.316    -0.000001    -0.000001 
  798.302    -0.000000    -0.000000 
  801.287     0.000000    -0.000000 
  804.327    -0.000001    -0.000000 
  807.310    -0.000000    -0.000000 
  810.348    -0.000000    -0.000000 
  813.331     0.000000    -0.000000 
  816.312    -0.000000    -0.000000 
  819.348    -0.000000    -0.000000 
  822.328     0.000000    -0.000000 
  825.362    -0.000000     0.000000 
  828.341     0.000000     0.000000 
  831.374     0.000000     0.000000 
  834.351     0.000000     0.000000 
  837.382    -0.000000     0.000000 
  840.357    -0.000000     0.000000 
  843.387     0.000022     0.000024 
  846.361     0.000002     0.000004 
  849.389     0.000002     0.000002 
  852.362     0.000000     0.000000 
  855.389    -0.000000    -0.000000 
  858.359    -0.000000    -0.000000 
  861.385    -0.000000     0.000000 
  864.409     0.000000     0.000000 
  867.378     0.000000     0.000001 
  870.400     0.000002     0.000001 
  873.422     0.000001     0.000000 
  876.389     0.000001    -0.000000 
  879.409     0.000000    -0.000000 
  882.428     0.000000    -0.000000 
  885.447     0.000000    -0.000000 
  888.410    -0.000000    -0.000000 
  891.427     0.000000    -0.000000 
  894.444    -0.000000    -0.000000 
  897.459    -0.000000    -0.000000 
  900.419     0.000003     0.000006 
  903.433     0.000004     0.000003 
  906.446     0.000001    -0.000000 
  909.458     0.000000     0.000000 
  912.469    -0.000000    -0.000000 
  915.480     0.000000     0.000000 
  918.489     0.000000     0.000000 
  921.443     0.000000     0.000000 
  924.451     0.000000     0.000000 
  927.458    -0.000000    -0.000000 
  930.465    -0.000000    -0.000000 
  933.470    -0.000000     0.000000 
  936.475    -0.000000    -0.000000 
  939.478    -0.000000    -0.000000 
  942.481    -0.000000    -0.000000 
  945.483    -0.000000    -0.000000 
  948.484    -0.000000    -0.000000 
  951.484    -0.000000    -0.000000 
  954.538    -0.000000    -0.000000 
  957.537    -0.000000    -0.000000 
  960.534     0.000000    -0.000000 
  963.531     0.000000     0.000000 
  966.526    -0.000000    -0.000000 
  969.521     0.000000    -0.000000 
  972.515     0.000000    -0.000000 
  975.563     0.000000    -0.000000 
  978.555     0.000000    -0.000000 
  981.546     0.000000    -0.000000 
  984.537     0.000000     0.000000 
  987.580     0.000000     0.000000 
  990.569     0.000000     0.000000 
  993.556     0.000000     0.000000 
  996.543     0.000000     0.000000 
  999.583     0.000000     0.000000 
 1002.568     0.000000     0.000000 
 1005.552     0.000000     0.000000 
 1008.589     0.000000     0.000000 
 1011.571     0.000000     0.000000 
 1014.606     0.000000     0.000000 
 1017.587     0.000000     0.000000 
 1020.620     0.000000     0.000000 
 1023.598     0.000000     0.000000 
 1026.629     0.000000     0.000000 
 1029.606     0.000000     0.000000 
 1032.635     0.000000     0.000000 
 1035.610     0.000000     0.000000 
 1038.637     0.000000     0.000000 
 1041.610     0.000000    -0.000000 
 1044.635     0.000000    -0.000000 
 1047.660     0.000000     0.000000 
 1050.629     0.000000     0.000000 
 1053.652     0.000000     0.000000 
 1056.620     0.000000    -0.000000 
 1059.640     0.000000     0.000000 
 1062.660     0.000000     0.000000 
 1065.678     0.000000     0.000000 
 1068.642     0.000000     0.000000 
 1071.658     0.000000     0.000000 
 1074.674     0.000000     0.000000 
 1077.688     0.000000     0.000000 
 1080.702     0.000000     0.000000 
 1083.660     0.000000     0.000000 
 1086.672     0.000000     0.000000 
 1089.682     0.000000     0.000000 
 1092.691     0.000000     0.000000 
 1095.699     0.000000     0.000000 
 1098.707     0.000000     0.000000 
 1101.713     0.000000     0.000000 
 1104.718     0.000000     0.000000 
 1107.722     0.000000     0.000000 
 1110.725     0.000000     0.000000 
 1113.727     0.000000     0.000000 
 1116.728     0.000000     0.000000 
 1119.728     0.000000     0.000000 
 1122.726     0.000000     0.000000 
 1125.724     0.000000     0.000000 
 1128.720     0.000000     0.000000 
 1131.770     0.000000     0.000000 
 1134.764     0.000000     0.000000 
 1137.757     0.000000     0.000000 
 1140.749     0.000000     0.000000 
 1143.741     0.000000     0.000000 
 1146.784     0.000000     0.000000 
 1149.773     0.000000     0.000000 
 1152.761     0.000000     0.000000 
 1155.801     0.000000     0.000000 
 1158.786     0.000000     0.000000 
 1161.771     0.000000     0.000000 
 1164.807     0.000000     0.000000 
 1167.790     0.000000     0.000000 
 1170.771     0.000000     0.000000 
 1173.804     0.000000     0.000000 
 1176.783     0.000000     0.000000 
 1179.814     0.000000     0.000000 
 1182.790     0.000000     0.000000 
 1185.819     0.000000     0.000000 
 1188.793     0.000000     0.000000 
 1191.820     0.000000     0.000000 
 1194.845     0.000000     0.000000 
 1197.815     0.000000     0.000000 
 1200.838     0.000000     0.000000 