# number of points on sci filter + aux + bad z = 2
# number of points on sci filter               = 2
# number of positions in lambda                = 301
# noof scans  1            1          
# x_pos     162.640000  -162.640000 
# y_pos       0.000000     0.000000 
# angle       2.960000     2.960000 
# z_pos      10.000000    10.000000 
# r_pos     162.640000   162.640000 
# phi         0.000000     3.141593 
# gnupl col      2            3      
# pos_id        49           50      
#
# lambda for peak transmission
#          479.9160000  479.9160000 
# peak transmission
#            0.7903600    0.7861050 
# lambda blue with 1/2 of peak transmission
#          385.9488021  385.9339934 
# lambda red  with 1/2 of peak transmission
#          489.9922588  489.7803976 
# half width                              
#          104.0434567  103.8464042 
# central wavelength                      
#          437.9705305  437.8571955 
# central wavelength calculated as SAGEM (mean frequency)
#          431.7914384  431.6998936 
# lambda blue with 80% of peak transmission
#          411.7534622  411.5389971 
# lambda red  with 80% of peak transmission
#          487.2498346  487.0434588 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.7243721    0.7204744 
# ATB calculated from points above 50%
#            0.6783425    0.6741686 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000 
# minCWL      = 437.857195 at column =  3, at id = 50 
# maxCWL      = 437.970530 at column =  2, at id = 49 
# difference =    0.1133350 
# minBW       = 103.846404 at column =  3, at id = 50 
# maxBW       = 104.043457 at column =  2, at id = 49 
# difference =    0.1970525 
# minATB80    = 0.720474 at column =  3, at id = 50 
# maxATB80    = 0.724372 at column =  2, at id = 49 
# difference =    0.0038977 
# minBlueEdge = 385.933993 at column =  3, at id = 50 
# maxBlueEdge = 385.948802 at column =  2, at id = 49 
# difference =    0.0148087 
# minRedEdge  = 489.780398 at column =  3, at id = 50 
# maxRedEdge  = 489.992259 at column =  2, at id = 49 
# difference =    0.2118613 
# minABR      = 9.999900 at column =  2, at id = 49 
# maxABR      = 9.999900 at column =  2, at id = 49 
# difference =    0.0000000 
  299.645    -0.000392     0.000097 
  302.654    -0.000182    -0.000102 
  305.662    -0.000092    -0.000065 
  308.671    -0.000074    -0.000009 
  311.679    -0.000037    -0.000043 
  314.687    -0.000064    -0.000006 
  317.694    -0.000024     0.000000 
  320.702    -0.000012     0.000008 
  323.709     0.000017     0.000010 
  326.716     0.000008     0.000015 
  329.665     0.000007    -0.000005 
  332.672     0.000015    -0.000007 
  335.678    -0.000008    -0.000008 
  338.683     0.000008    -0.000002 
  341.689     0.000010    -0.000009 
  344.694    -0.000002     0.000000 
  347.699     0.000001     0.000000 
  350.703    -0.000000    -0.000004 
  353.707    -0.000000    -0.000002 
  356.711     0.000002     0.000003 
  359.715    -0.000000     0.000000 
  362.718    -0.000002     0.000000 
  365.721    -0.000002     0.000003 
  368.724    -0.000002     0.000001 
  371.726    -0.000005     0.000000 
  374.728     0.000396     0.000535 
  377.730     0.018567     0.019780 
  380.788     0.119511     0.122965 
  383.789     0.317029     0.316956 
  386.789     0.425582     0.423385 
  389.790     0.517461     0.515669 
  392.790     0.550032     0.546995 
  395.790     0.574069     0.571957 
  398.789     0.581997     0.577550 
  401.788     0.602845     0.601719 
  404.787     0.617290     0.615483 
  407.785     0.617553     0.614429 
  410.783     0.626865     0.624346 
  413.781     0.643618     0.642342 
  416.834     0.654491     0.652168 
  419.831     0.667218     0.665958 
  422.828     0.673228     0.670804 
  425.824     0.675437     0.673211 
  428.820     0.688467     0.686629 
  431.815     0.692794     0.690189 
  434.810     0.686420     0.682024 
  437.862     0.709279     0.706970 
  440.856     0.718962     0.715488 
  443.850     0.708700     0.702642 
  446.844     0.714733     0.711480 
  449.837     0.738807     0.735021 
  452.830     0.736110     0.730023 
  455.878     0.730786     0.725968 
  458.870     0.755533     0.752856 
  461.862     0.765491     0.762773 
  464.853     0.762101     0.757724 
  467.901     0.758081     0.753442 
  470.891     0.772000     0.768846 
  473.881     0.775166     0.769374 
  476.871     0.778242     0.775004 
  479.916     0.790360     0.786105 
  482.905     0.785366     0.779552 
  485.894     0.728437     0.715737 
  488.882     0.516543     0.489964 
  491.925     0.183911     0.161711 
  494.913     0.041595     0.035922 
  497.899     0.012973     0.011503 
  500.942     0.004366     0.003834 
  503.928     0.001394     0.001220 
  506.913     0.000693     0.000629 
  509.954     0.000331     0.000301 
  512.939     0.000149     0.000126 
  515.923     0.000075     0.000060 
  518.963     0.000047     0.000041 
  521.946     0.000036     0.000032 
  524.929     0.000021     0.000014 
  527.967     0.000018     0.000015 
  530.949     0.000016     0.000013 
  533.987     0.000014     0.000000 
  536.968     0.000004     0.000003 
  539.948     0.000005     0.000002 
  542.984     0.000005     0.000002 
  545.964     0.000004     0.000001 
  548.999     0.000002     0.000001 
  551.977     0.000002     0.000000 
  555.012     0.000001     0.000001 
  557.989     0.000001     0.000000 
  561.023     0.000002     0.000001 
  563.999     0.000001     0.000000 
  567.032     0.000001     0.000000 
  570.007     0.000001     0.000000 
  573.038     0.000000    -0.000000 
  576.013     0.000001    -0.000000 
  579.043    -0.000000    -0.000001 
  582.017    -0.000000    -0.000001 
  585.046     0.000000    -0.000001 
  588.019     0.000000    -0.000001 
  591.047     0.000000    -0.000001 
  594.019     0.000000    -0.000001 
  597.046    -0.000000    -0.000001 
  600.073    -0.000000    -0.000001 
  603.043    -0.000000    -0.000001 
  606.068     0.000000    -0.000000 
  609.038     0.000000    -0.000001 
  612.062    -0.000000    -0.000000 
  615.086    -0.000000    -0.000001 
  618.053     0.000000    -0.000001 
  621.076    -0.000000    -0.000001 
  624.099     0.000001    -0.000000 
  627.064     0.000001    -0.000000 
  630.086     0.000001    -0.000000 
  633.106     0.000000    -0.000000 
  636.071     0.000001    -0.000000 
  639.090     0.000000    -0.000000 
  642.109     0.000000    -0.000000 
  645.128    -0.000000    -0.000001 
  648.090    -0.000000    -0.000000 
  651.107    -0.000000    -0.000000 
  654.123     0.000001     0.000000 
  657.139    -0.000000    -0.000000 
  660.099     0.000000    -0.000000 
  663.114    -0.000001    -0.000001 
  666.129     0.000000    -0.000001 
  669.142     0.000000     0.000000 
  672.155     0.000002     0.000001 
  675.168     0.000000    -0.000001 
  678.124     0.000000    -0.000000 
  681.136     0.000000    -0.000001 
  684.146    -0.000000    -0.000001 
  687.157     0.000000    -0.000001 
  690.166     0.000000    -0.000002 
  693.175     0.000030     0.000037 
  696.183     0.000123     0.000104 
  699.191     0.000000    -0.000001 
  702.198     0.000000    -0.000000 
  705.205    -0.000000     0.000000 
  708.211    -0.000001     0.000000 
  711.216     0.000003     0.000009 
  714.220     0.000002     0.000001 
  717.224     0.000001    -0.000000 
  720.228    -0.000000    -0.000001 
  723.230    -0.000000    -0.000000 
  726.232    -0.000000    -0.000001 
  729.234    -0.000000    -0.000001 
  732.234    -0.000000    -0.000001 
  735.235    -0.000000    -0.000001 
  738.234     0.000000    -0.000002 
  741.233     0.000001    -0.000001 
  744.231     0.000000    -0.000001 
  747.228    -0.000001    -0.000002 
  750.225    -0.000000    -0.000002 
  753.221     0.000000    -0.000001 
  756.272     0.000001    -0.000001 
  759.267     0.000002     0.000001 
  762.261     0.000055     0.000050 
  765.254     0.000028     0.000013 
  768.247    -0.000001     0.000003 
  771.294     0.000056     0.000051 
  774.286     0.000037     0.000015 
  777.277     0.000002    -0.000002 
  780.266     0.000001    -0.000002 
  783.311    -0.000001    -0.000001 
  786.300     0.000001    -0.000001 
  789.288     0.000001    -0.000001 
  792.275     0.000029     0.000025 
  795.316    -0.000002    -0.000002 
  798.302    -0.000000    -0.000000 
  801.287     0.000000    -0.000001 
  804.327    -0.000002    -0.000001 
  807.310    -0.000001    -0.000001 
  810.348    -0.000001    -0.000001 
  813.331     0.000001    -0.000001 
  816.312    -0.000000    -0.000001 
  819.348    -0.000000    -0.000001 
  822.328     0.000000    -0.000000 
  825.362    -0.000001     0.000001 
  828.341     0.000000     0.000000 
  831.374     0.000000     0.000000 
  834.351     0.000000     0.000000 
  837.382    -0.000001     0.000001 
  840.357    -0.000001     0.000001 
  843.387     0.000055     0.000060 
  846.361     0.000005     0.000010 
  849.389     0.000006     0.000004 
  852.362     0.000000     0.000000 
  855.389    -0.000001    -0.000001 
  858.359    -0.000001    -0.000000 
  861.385    -0.000001     0.000000 
  864.409     0.000000     0.000001 
  867.378     0.000001     0.000002 
  870.400     0.000005     0.000003 
  873.422     0.000003     0.000000 
  876.389     0.000002    -0.000001 
  879.409     0.000000    -0.000000 
  882.428     0.000000    -0.000000 
  885.447     0.000000    -0.000000 
  888.410    -0.000000    -0.000000 
  891.427     0.000000    -0.000000 
  894.444    -0.000000    -0.000001 
  897.459    -0.000000    -0.000001 
  900.419     0.000013     0.000022 
  903.433     0.000014     0.000010 
  906.446     0.000003    -0.000000 
  909.458     0.000001     0.000001 
  912.469    -0.000001    -0.000000 
  915.480     0.000000     0.000001 
  918.489     0.000001     0.000001 
  921.443     0.000001     0.000002 
  924.451     0.000001     0.000001 
  927.458    -0.000000    -0.000001 
  930.465    -0.000000    -0.000001 
  933.470    -0.000001     0.000001 
  936.475    -0.000000    -0.000001 
  939.478    -0.000000    -0.000000 
  942.481    -0.000001    -0.000001 
  945.483    -0.000001    -0.000001 
  948.484    -0.000001    -0.000000 
  951.484    -0.000000    -0.000000 
  954.538    -0.000001    -0.000000 
  957.537    -0.000000    -0.000002 
  960.534     0.000000    -0.000001 
  963.531     0.000000     0.000000 
  966.526    -0.000000    -0.000000 
  969.521     0.000001    -0.000001 
  972.515     0.000001    -0.000000 
  975.563     0.000001    -0.000001 
  978.555     0.000001    -0.000000 
  981.546     0.000002    -0.000000 
  984.537     0.000002     0.000001 
  987.580     0.000003     0.000001 
  990.569     0.000002     0.000001 
  993.556     0.000002     0.000001 
  996.543     0.000003     0.000001 
  999.583     0.000003     0.000000 
 1002.568     0.000003     0.000000 
 1005.552     0.000001     0.000001 
 1008.589     0.000003     0.000001 
 1011.571     0.000003     0.000001 
 1014.606     0.000003     0.000001 
 1017.587     0.000003     0.000002 
 1020.620     0.000002     0.000002 
 1023.598     0.000003     0.000001 
 1026.629     0.000002     0.000001 
 1029.606     0.000003     0.000000 
 1032.635     0.000002     0.000001 
 1035.610     0.000003     0.000001 
 1038.637     0.000003     0.000000 
 1041.610     0.000003    -0.000000 
 1044.635     0.000004    -0.000000 
 1047.660     0.000003     0.000000 
 1050.629     0.000003     0.000000 
 1053.652     0.000004     0.000002 
 1056.620     0.000005    -0.000000 
 1059.640     0.000006     0.000001 
 1062.660     0.000006     0.000000 
 1065.678     0.000006     0.000003 
 1068.642     0.000006     0.000004 
 1071.658     0.000007     0.000002 
 1074.674     0.000008     0.000001 
 1077.688     0.000009     0.000000 
 1080.702     0.000009     0.000004 
 1083.660     0.000009     0.000004 
 1086.672     0.000016     0.000008 
 1089.682     0.000020     0.000009 
 1092.691     0.000040     0.000014 
 1095.699     0.000072     0.000015 
 1098.707     0.000080     0.000043 
 1101.713     0.000101     0.000088 
 1104.718     0.000122     0.000127 
 1107.722     0.000179     0.000165 
 1110.725     0.000300     0.000248 
 1113.727     0.000379     0.000288 
 1116.728     0.000509     0.000483 
 1119.728     0.000644     0.000682 
 1122.726     0.000986     0.000989 
 1125.724     0.001535     0.001528 
 1128.720     0.002359     0.002380 
 1131.770     0.003671     0.003740 
 1134.764     0.005839     0.005999 
 1137.757     0.009379     0.009743 
 1140.749     0.016116     0.016884 
 1143.741     0.029581     0.031434 
 1146.784     0.058650     0.062990 
 1149.773     0.122134     0.132844 
 1152.761     0.258747     0.284711 
 1155.801     0.502993     0.545269 
 1158.786     0.674791     0.654033 
 1161.771     0.679711     0.667562 
 1164.807     0.670018     0.654621 
 1167.790     0.596051     0.554336 
 1170.771     0.525627     0.491774 
 1173.804     0.489300     0.463493 
 1176.783     0.484215     0.464172 
 1179.814     0.506093     0.490179 
 1182.790     0.548650     0.535160 
 1185.819     0.592979     0.579325 
 1188.793     0.620958     0.609282 
 1191.820     0.641306     0.624714 
 1194.845     0.656416     0.646821 
 1197.815     0.000000     0.000000 
 1200.838     0.000000     0.000000 