mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
ISAAC:
grating & slit
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
ISAAC trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2013-12-16T10:01:49 (UT)
  | now: 2024-11-23T06:59:02 (UT) muc03 QC pipeline: isaac-6.1.3 (installed 2013-04-15)
same group: GratingCheck NightAcq DayCalSlit
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
ISAAC news: 2013-12-16: due to ISAAC decommissioning, refreshing of the health checks disabled
Report news:
DATE*: [?] 2013-12-09
report | NLT
2013-12-10
report | NLT
2013-12-11
report | NLT
2013-12-12
report | NLT
2013-12-13
no data | NLT
2013-12-14
no data | NLT
2013-12-15
no data | NLT
P...
Product quality:
products products products products no products no products no products
  last OPSLOG data:
2013-12-11*

last files ...
[an error occurred while processing this directive]
monitor

scores&comments | history ... | plot tutorial ... | contact                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
  • Only the first acquisition frame of the Move_to_slit template is shown
  • Flux values are dependent on slit width
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (0) MEDIAN 510 PIXEL VAL500,521 154 qc_slit_x this | last_yr | all X-position of the slit image
2 QC1DB yes (0) MEDIAN 492 PIXEL VAL520,540 154 qc_slit_y this | last_yr | all Y-position of the slit image
3 QC1DB yes (0) MEDIAN -89.6 DEGREE none  154 qc_slit_a this | last_yr | all Tilt angle of the slit image
4 QC1DB yes (0) MEDIAN 4.59e+06 ADU none  154 qc_slit_f this | last_yr | all integrated flux of the slit image
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: not implemented
data source:isaac_slit
(QC1 database)
dataset:qc_slit_x
median:510PIXEL
fixed thresholds:500...521PIXEL
N_data plotted:154
[click on plot for closeup]
Plot 2
scores: not implemented
data source:isaac_slit
(QC1 database)
dataset:qc_slit_y
median:492PIXEL
fixed thresholds:520...540PIXEL
N_data plotted:154
[click on plot for closeup]
Plot 3
scores: not implemented
data source:isaac_slit
(QC1 database)
dataset:qc_slit_a
median:-89.6DEGREE
thresholds:none 
N_data plotted:154
[click on plot for closeup]
Plot 4
scores: not implemented
data source:isaac_slit
(QC1 database)
dataset:qc_slit_f
median:4.59e+06ADU
thresholds:none 
N_data plotted:154
[click on plot for closeup]
This plot

This is the trending plot of the through slit images taken as part of the acquisition template for spectroscopy.

This plot describes:
1. The x-position of the slit image.
2. The y-position of the slit image.
3. The tilt angle of the slit image.
4. The flux of the slit image.

The ISAAC acquisition template used for spectroscopy (science observations as well as standard stars use to calibrate telluric lines) generates an acquisition image, or a difference image with TPL.EXPNO=1, followed by an unpredicted number of through slit images taken in an interactive way by the night time astronomer to align the optics. Only the first in the sequence of the through slit images with TPL.EXPNO=2 is investigated here to check how far the camera has been moved after the last alignment. Find more information about ISAAC slit frames here.

 


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up