[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
VISIR trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2024-09-26T02:02:46 (UT)
  | now: 2024-09-27T00:41:50 (UT) muc03 QC pipeline: visir-4.4.3 (installed 2023-04-27)
close window history: 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH FULL
  ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 4.39 mJy/1hr none  1132 sensit all (full time range) sensitivity with PAH1 filter, pfov=0.0453
2 QC1DB MEDIAN 6.68 mJy/1hr none  522 sensit all (full time range) sensitivity with PAH2_2 filter, pfov=0.0453
3 QC1DB MEDIAN 9.05 mJy/1hr none  98 sensit all (full time range) sensitivity with ArIII filter, pfov=0.0453
4 QC1DB MEDIAN 3.82 mJy/1hr none  291 sensit all (full time range) sensitivity with J8.9 filter, pfov=0.0453
5 QC1DB MEDIAN 3.68 mJy/1hr none  1014 sensit all (full time range) sensitivity with B10.7 filter, pfov=0.0453
6 QC1DB MEDIAN 15.2 mJy/1hr none  536 sensit all (full time range) sensitivity with NeII filter, pfov=0.0453
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:visir_zp_img
(QC1 database)
dataset:sensit
median:4.39mJy/1hr
thresholds:none 
N_data plotted:1132
[click plot for closeup]
Plot 2
scores: not implemented
data source:visir_zp_img
(QC1 database)
dataset:sensit
median:6.68mJy/1hr
thresholds:none 
N_data plotted:522
[click plot for closeup]
Plot 3
scores: not implemented
data source:visir_zp_img
(QC1 database)
dataset:sensit
median:9.05mJy/1hr
thresholds:none 
N_data plotted:98
[click plot for closeup]
Plot 4
scores: not implemented
data source:visir_zp_img
(QC1 database)
dataset:sensit
median:3.82mJy/1hr
thresholds:none 
N_data plotted:291
[click plot for closeup]
Plot 5
scores: not implemented
data source:visir_zp_img
(QC1 database)
dataset:sensit
median:3.68mJy/1hr
thresholds:none 
N_data plotted:1014
[click plot for closeup]
Plot 6
scores: not implemented
data source:visir_zp_img
(QC1 database)
dataset:sensit
median:15.2mJy/1hr
thresholds:none 
N_data plotted:536
[click plot for closeup]
This plot

Measurements of the sensitivity parameter for several N band filters. Note that starting with P95 only small-field (SF) observations with 0.0453 arcsec/pixel are offered.

Sensitivity is determined by observing a standard star and estimating the limiting flux expected in 1 hour "on-source" integration of a point-source detected with S/N of 10. It is given in units of mJy at 10 sigma in 1 hr.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up