[page auto-refreshes after 60 sec]            [press Ctrl+R to enforce refresh of scores and dates]
VIMOS trending system: HISTORY plot
Last update: 2009-02-11T13:39:36 (UT)
same group: LRb_cent LRr_cent MR_cent HRb_cent HRo_cent HRr_cent   LRb_full LRr_full MR_full HRb_full HRo_full HRr_full
close window history: 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018   HEALTH
  ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   none none   148 resol3 this | last_yr | all spectral resolution, blue end
1 QC1DB none   none none   148 resol1 this | last_yr | all spectral resolution, red end
1 QC1DB MEDIAN 554.065 none VAL450,650 148 resol2 this | last_yr | all spectral resolution, centre
2 QC1DB none   none none   149 resol3 this | last_yr | all spectral resolution, blue end
2 QC1DB none   none none   149 resol1 this | last_yr | all spectral resolution, red end
2 QC1DB MEDIAN 533.68201 none VAL450,650 149 resol2 this | last_yr | all spectral resolution, centre
3 QC1DB none   none none   158 resol3 this | last_yr | all spectral resolution, blue end
3 QC1DB none   none none   158 resol1 this | last_yr | all spectral resolution, red end
3 QC1DB MEDIAN 554.72699 none VAL450,650 158 resol2 this | last_yr | all spectral resolution, centre
4 QC1DB none   none none   148 resol3 this | last_yr | all spectral resolution, blue end
4 QC1DB none   none none   148 resol1 this | last_yr | all spectral resolution, red end
4 QC1DB MEDIAN 545.94897 none VAL450,650 148 resol2 this | last_yr | all spectral resolution, centre
*Data sources: QC1DB: QC1 database; LOCAL: local text file
This plot

Trending plot for resolution (resolving power R) derived from MOS arc lamp measurements.

Only arc lamp measurements taken to calibrate MOS science observations are used; exposures with the standard star masks are disregarded. Only measurements with slit_width_dis=1.0 are plotted.

Resolution is measured at the blue and the red end, and at the centre of the spectral range. The "cent" plots only show the latter; they include scoring. The "full" plots also show the results at the blue and red ends; these are not scored.

For LR_blue, the resolution at the blue and red ends is usually not well determined; therefore only the central value is plotted.

For MR, there is a similar issue at the blue end for masks with multiplexing: spectra from slits which are at the same x position can overlap and the pipeline then reports R=0 for the resolving power at the blue end.

Template ID: mos_cal_Arc (daytime), mos_cal_NightCalib (attached night-time). Pipeline recipe: vmspcaldisp.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up