[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
UVES trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2024-06-30T06:17:51 (UT)
  | now: 2024-06-30T12:53:56 (UT) muc02 QC pipeline: uves-6.1.11 (installed 2023-06-22)
close window history: 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH FULL
  ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN -0.07 pixels none  485 mean_dx all (full time range) DeltaX between solution and Physical Model, from MOS FMTCHK data, 520.0nm, 1x1, Plate 2, RED UPPER CCD
2 QC1DB MEDIAN 2.9 pixels none  485 mean_dy all (full time range) DeltaY, same data set
3 QC1DB MEDIAN 588 pixels none  485 nlin_sel all (full time range) Number of lines used in the solution, same data set

4 QC1DB MEDIAN 0.337 pixels none  487 mean_dx all (full time range) DeltaX between solution and physical model, 520.0nm, 1x1, Plate 2, RED LOWER CCD
5 QC1DB MEDIAN 1.74 pixels none  487 mean_dy all (full time range) DeltaY, same data set
6 QC1DB MEDIAN 829 pixels none  487 nlin_sel all (full time range) Number of lines used in the solution, same data set
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dx
median:-0.07pixels
thresholds:none 
N_data plotted:485
[click plot for closeup]
Plot 2
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dy
median:2.9pixels
thresholds:none 
N_data plotted:485
[click plot for closeup]
Plot 3
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:nlin_sel
median:588pixels
thresholds:none 
N_data plotted:485
[click plot for closeup]
Plot 4
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dx
median:0.337pixels
thresholds:none 
N_data plotted:487
[click plot for closeup]
Plot 5
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dy
median:1.74pixels
thresholds:none 
N_data plotted:487
[click plot for closeup]
Plot 6
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:nlin_sel
median:829pixels
thresholds:none 
N_data plotted:487
[click plot for closeup]
This plot

This is the trending report for the grating stability in FLAMES/UVES, derived from the MOS format check calibrations taken with wavelength setting 520, 1x1 binning and Plate 2. These data are only rarely taken and plotted here for completeness. They are not scored to avoid redundancy with the plate 1 plot.

Find more inforamtion in the description of the corresponding plot for plate 1.

Find more information about FLAMES/UVES Grating Position monitoring here.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up