[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
SPHERE trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-23T04:32:12 (UT)
  | now: 2024-11-23T17:58:07 (UT) muc03 QC pipeline: spher-0.56.0 (installed 2024-09-26)
same group: CI_HIGH_FLAT CI_RMS   CI_FPN CI_NBP
close window history: 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH
  ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.0247025 fractional_fp_noise VAL0.01,0.03 14 qc_fpn_left this | last_yr | all Y-band left beam
2 QC1DB MEDIAN 0.0232025 fractional_fp_noise VAL0.01,0.03 14 qc_fpn_left this | last_yr | all J-band left beam
3 QC1DB MEDIAN 0.022751 fractional_fp_noise VAL0.01,0.03 31 qc_fpn_left this | last_yr | all H-band left beam
4 QC1DB MEDIAN 0.021419 fractional_fp_noise VAL0.01,0.03 23 qc_fpn_left this | last_yr | all K-band left beam
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: no current data
data source:sphere_irdis_flat
(QC1 database)
dataset:qc_fpn_left
median:0.0247025fractional_fp_noise
fixed thresholds:0.01...0.03fractional_fp_noise
N_data plotted:14
[click plot for closeup]
Plot 2
scores: no current data
data source:sphere_irdis_flat
(QC1 database)
dataset:qc_fpn_left
median:0.0232025fractional_fp_noise
fixed thresholds:0.01...0.03fractional_fp_noise
N_data plotted:14
[click plot for closeup]
Plot 3
scores: no current data
data source:sphere_irdis_flat
(QC1 database)
dataset:qc_fpn_left
median:0.022751fractional_fp_noise
fixed thresholds:0.01...0.03fractional_fp_noise
N_data plotted:31
[click plot for closeup]
Plot 4
scores: no current data
data source:sphere_irdis_flat
(QC1 database)
dataset:qc_fpn_left
median:0.021419fractional_fp_noise
fixed thresholds:0.01...0.03fractional_fp_noise
N_data plotted:23
[click plot for closeup]
This plot

This plot shows the fractional fixed pattern noise derived from the normalized master flat. The QC parameter is monitored for the left beam and for the four broad band filters in the common filter wheel: B_Y, B_H, B_J and B_K, separately. The dual beam filter wheel is 'CLEAR' in classical imaging mode.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up