[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
SPHERE trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2024-11-17T06:02:10 (UT)
  | now: 2024-11-23T12:21:39 (UT) muc03 QC pipeline: spher-0.56.0 (installed 2024-09-26)
close window history: 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH FULL
  ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   ADU none  734 qc_raw_counts_iframe all (full time range) readmode = SlowPolarimetry, CAM=1
2 QC1DB none   ADU none  736 qc_raw_counts_iframe all (full time range) readmode = SlowPolarimetry, CAM=2
3 QC1DB none   ADU none  1291 qc_raw_counts_iframe all (full time range) readmode = FastPolarimetry, CAM=1
4 QC1DB none   ADU none  1292 qc_raw_counts_iframe all (full time range) readmode = FastPolarimetry, CAM=2
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:sphere_zimpol_modem_eff
(QC1 database)
dataset:qc_raw_counts_iframe
average:none
thresholds:none
N_data plotted:734
[click plot for closeup]
Plot 2
scores: not implemented
data source:sphere_zimpol_modem_eff
(QC1 database)
dataset:qc_raw_counts_iframe
average:none
thresholds:none
N_data plotted:736
[click plot for closeup]
Plot 3
scores: not implemented
data source:sphere_zimpol_modem_eff
(QC1 database)
dataset:qc_raw_counts_iframe
average:none
thresholds:none
N_data plotted:1291
[click plot for closeup]
Plot 4
scores: not implemented
data source:sphere_zimpol_modem_eff
(QC1 database)
dataset:qc_raw_counts_iframe
average:none
thresholds:none
N_data plotted:1292
[click plot for closeup]
This plot

The four boxes show the counts in the raw frames of the modulation demodulation efficiency calibrations for

  • both detectors (CAM1 and CAM2) and
  • both readmodes (S= SlowPolarimetry and F=FastPolarimetry).

The counts in the raw frames are composed of a bias level of ~1000 ADU plus lamp flux. For every raw frame, the counts are taken in one even row (pixel area = [60 268 260 268]) and in one odd row (pixel area = [60 269 260 269]). The average over all raw frame planes of the cube is taken, resulting in a mean odd_row and a mean even_row counts for both detectors. The maximum between the even_row and odd_row values is taken, for both cameras separately. The maximum over all raw frames is taken. This QC parameter is used to check for saturation and under-illumination.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up