The zeropoint is calculated on the star of the month. It is calculated using
zpoint=mag + 2.5*log10(flux/DIT)
where mag is the magnitude of the object in N band
flux is the Target Photometry of beam A or B (measured in bin2)
DIT is the detector DIT
There are no correction applied