mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
MIDI:
Star of the month
Other HC:
QC links:
[an error occurred while processing this directive]
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
MIDI trending system: HEALTH CHECK report
Last update: 2012-01-29T20:21:37 (UT)
| now: 2024-06-29T21:20:48 (UT)
HELP USERS-GUIDE MORE
same group: TF2_HS TF2_SP PHOT ZPOINT
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
The links to KMOS, UVES, and ESPRESSO have been moved to a new section (qcFlow operational) at the lower part of the navigation bar.
MIDI news:  
Report news:  
DATE*: [?] 2015-02-27
report | NLT
2015-02-28
report | NLT
2015-03-01
report | NLT
2015-03-02
report | NLT
2015-03-03
report | NLT
2015-03-04
report | NLT
2015-03-05
no data | NLT
P...
Product quality:
products products products products products products no products
  no OPSLOG data  
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no none   NONE VAL17,19 7 averaged_err_photA this | last_yr | all alfhya
1 QC1DB no none   NONE VAL17,19 0 averaged_err_photA this | last_yr | all alftau
1 QC1DB no none   NONE VAL17,19 32 averaged_err_photA this | last_yr | all etasgr
1 QC1DB no none   NONE VAL17,19 5 averaged_err_photA this | last_yr | all alfboo
1 QC1DB no none   NONE VAL17,19 6 averaged_err_photA this | last_yr | all siglib
1 QC1DB no none   NONE VAL17,19 14 averaged_err_photA this | last_yr | all alfcma
2 QC1DB no none   NONE VAL17,19 7 averaged_err_photB this | last_yr | all alfhya
2 QC1DB no none   NONE VAL17,19 0 averaged_err_photB this | last_yr | all alftau
2 QC1DB no none   NONE VAL17,19 32 averaged_err_photB this | last_yr | all etasgr
2 QC1DB no none   NONE VAL17,19 5 averaged_err_photB this | last_yr | all alfboo
2 QC1DB no none   NONE VAL17,19 6 averaged_err_photB this | last_yr | all siglib
2 QC1DB no none   NONE VAL17,19 14 averaged_err_photB this | last_yr | all alfcma
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: not implemented
data source:midi_TransferFunction
(QC1 database)
dataset:
(numbers below apply to this dataset)
averaged_err_photA
average:none
fixed thresholds:17.0...19.0NONE
N_data plotted:7
[click on plot for closeup]
Plot 2
scores: not implemented
data source:midi_TransferFunction
(QC1 database)
dataset:
(numbers below apply to this dataset)
averaged_err_photB
average:none
fixed thresholds:17.0...19.0NONE
N_data plotted:7
[click on plot for closeup]
This plot

The zeropoint is calculated on the star of the month. It is calculated using
zpoint=mag + 2.5*log10(flux/DIT)
where mag is the magnitude of the object in N band, flux is the Target Photometry of beam A or B (measured in bin2), and DIT is the detector DIT. There are no corrections applied.

Please note that the zeropoint parameters in the QC1 database are misleadingly called averaged_err_photA and averaged_err_photB.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up