[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
ISAAC trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2013-12-16T10:00:55 (UT)
  | now: 2024-12-22T18:05:35 (UT) muc03 QC pipeline: isaac-6.1.3 (installed 2013-04-15)
same group: SW_extinct   FOV-grad SW-arm SW-band/LW-arm LW-arm
close window history: 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012   2013   HEALTH
  ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
  • Outliers in the gradient (dF/dx) are only meaningful when the RMS(dF/dy) is small, otherwise the deviation of dF/dx is due to a larger scatter in the measurement (e.g. non-photometric conditions, or high sky-variations). The same holds for dF/dy; here the RMS(dF/dx) should be low.
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no none   ADU/pixel VAL-0.1,0.1 34 qc_grad_x this | last_yr | all H-band: FOV gradient in x-direction of standard star flux
1 QC1DB no none   ADU/pixel VAL-0.1,0.1 27 qc_grad_x this | last_yr | all Js-band: FOV gradient in x-direction of standard star flux
1 oQC1DB no none   ADU/pixel VAL-0.1,0.1 28 qc_grad_x this | last_yr | all J-band: FOV gradient in x-direction of standard star flux
1 QC1DB no none   ADU/pixel VAL-0.1,0.1 29 qc_grad_x this | last_yr | all Ks-band: FOV gradient in x-direction of standard star flux
2 QC1DB no none   ADU/pixel VAL-0.1,0.1 34 qc_grad_y this | last_yr | all H-band: FOV gradient in y-direction of standard star flux
2 QC1DB no none   ADU/pixel VAL-0.1,0.1 27 qc_grad_y this | last_yr | all Js-band: FOV gradient in y-direction of standard star flux
2 oQC1DB no none   ADU/pixel VAL-0.1,0.1 28 qc_grad_y this | last_yr | all J-band: FOV gradient in y-direction of standard star flux
2 QC1DB no none   ADU/pixel VAL-0.1,0.1 29 qc_grad_y this | last_yr | all Ks-band: FOV gradient in y-direction of standard star flux
3 QC1DB no none   ADU/pixel VAL0,0.075 34 qc_grad_dx this | last_yr | all H-band: RMS in x-gradient
3 QC1DB no none   ADU/pixel VAL0,0.075 27 qc_grad_dx this | last_yr | all Js-band: RMS in x-gradient
3 oQC1DB no none   ADU/pixel VAL0,0.075 28 qc_grad_dx this | last_yr | all J-band: RMS in x-gradient
3 QC1DB no none   ADU/pixel VAL0,0.075 29 qc_grad_dx this | last_yr | all Ks-band: RMS in x-gradient
4 QC1DB no none   ADU/pixel VAL0,0.075 34 qc_grad_dy this | last_yr | all H-band: RMS of y-gradient
4 QC1DB no none   ADU/pixel VAL0,0.075 27 qc_grad_dy this | last_yr | all Js-band: RMS of y-gradient
4 oQC1DB no none   ADU/pixel VAL0,0.075 28 qc_grad_dy this | last_yr | all J-band: RMS of y-gradient
4 QC1DB no none   ADU/pixel VAL0,0.075 29 qc_grad_dy this | last_yr | all Ks-band: RMS of y-gradient
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: not implemented
data source:isaac_zp
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_grad_x
average:none
fixed thresholds:-0.1...0.1ADU/pixel
N_data plotted:34
[click on plot for closeup]
Plot 2
scores: not implemented
data source:isaac_zp
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_grad_y
average:none
fixed thresholds:-0.1...0.1ADU/pixel
N_data plotted:34
[click on plot for closeup]
Plot 3
scores: not implemented
data source:isaac_zp
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_grad_dx
average:none
fixed thresholds:0...0.075ADU/pixel
N_data plotted:34
[click on plot for closeup]
Plot 4
scores: not implemented
data source:isaac_zp
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_grad_dy
average:none
fixed thresholds:0...0.075ADU/pixel
N_data plotted:34
[click on plot for closeup]
This plot

This is the trending plot for the ISAAC QC parameters derived from photometric zeropoint frames. These plots describe:
1. The spatial gradient of the photometric zeropoint along the x-axis.
2. The spatial gradient of the photometric zeropoint along the y-axis.
3. The RMS of the gradient in x derived from the linear regression analysis
4. The RMS of the gradient in y derived from the linear regression analysis

The FOV gradients are derived from the five single raw frame exposures. Since the five measurements are acquired at five different positions on the detector, a simple spatial photometry can be derived for reasons of health check. These measurements serve as a quick look.

This QC check is complementory to the annualy acquired illumination checks. The illumination checks puts the star on a finer grid on the detetctor and fits a non-linear 2-dim polynomial. Find more information about ISAAC ZPOINT calibrations here.

Other QC parameters related to detector properties (like photometric zeropoints, linearity) are trended.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up