[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
ISAAC trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2013-12-16T10:03:15 (UT)
  | now: 2024-11-23T15:59:44 (UT) muc03 QC pipeline: isaac-6.1.3 (installed 2013-04-15)
same group: OddEven Statistics
close window history: 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012   2013   HEALTH
  ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (2) none   ADU VAL0.99,1.01 21 oc_UL_mean this | last_yr | all OddEvenCol Effect Mean value
2 QC1DB yes (2) none   ADU VAL0.99,1.01 21 oc_UR_mean this | last_yr | all OddEvenCol Effect Mean value
3 QC1DB yes (2) none   ADU VAL0.,0.0025 21 oc_UL_std this | last_yr | all OddEvenCol Effect Stdev value
4 QC1DB yes (2) none   ADU VAL0.,0.0025 21 oc_UR_std this | last_yr | all OddEvenCol Effect Stdev value
5 QC1DB yes (2) none   ADU VAL0.99,1.01 21 oc_LL_mean this | last_yr | all OddEvenCol Effect Mean value
6 QC1DB yes (2) none   ADU VAL0.99,1.01 21 oc_LR_mean this | last_yr | all OddEvenCol Effect Mean value
7 QC1DB yes (2) none   ADU VAL0.,0.0025 21 oc_LL_std this | last_yr | all OddEvenCol Effect Stdev value
8 QC1DB yes (2) none   ADU VAL0.,0.0025 21 oc_LR_std this | last_yr | all OddEvenCol Effect Stdev value
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: 2|
data source:isaac_twflat_oe
(QC1 database)
dataset:oc_UL_mean
average:none
fixed thresholds:0.99...1.01ADU
N_data plotted:21
[click on plot for closeup]
Plot 2
scores: 2|
data source:isaac_twflat_oe
(QC1 database)
dataset:oc_UR_mean
average:none
fixed thresholds:0.99...1.01ADU
N_data plotted:21
[click on plot for closeup]
Plot 5
scores: 2|
data source:isaac_twflat_oe
(QC1 database)
dataset:oc_LL_mean
average:none
fixed thresholds:0.99...1.01ADU
N_data plotted:21
[click on plot for closeup]
Plot 6
scores: 2|
data source:isaac_twflat_oe
(QC1 database)
dataset:oc_LR_mean
average:none
fixed thresholds:0.99...1.01ADU
N_data plotted:21
[click on plot for closeup]
Plot 3
scores: 2|
data source:isaac_twflat_oe
(QC1 database)
dataset:oc_UL_std
average:none
fixed thresholds:0.0...0.0025ADU
N_data plotted:21
[click on plot for closeup]
Plot 4
scores: 2|
data source:isaac_twflat_oe
(QC1 database)
dataset:oc_UR_std
average:none
fixed thresholds:0.0...0.0025ADU
N_data plotted:21
[click on plot for closeup]
Plot 7
scores: 2|
data source:isaac_twflat_oe
(QC1 database)
dataset:oc_LL_std
average:none
fixed thresholds:0.0...0.0025ADU
N_data plotted:21
[click on plot for closeup]
Plot 8
scores: 2|
data source:isaac_twflat_oe
(QC1 database)
dataset:oc_LR_std
average:none
fixed thresholds:0.0...0.0025ADU
N_data plotted:21
[click on plot for closeup]
This plot

This is the trending plot for the ISAAC twilight flat QC parameters of the SW-arm

These plots describe:
The so-called odd-even-column-effect (OE). The effect is monitored via two different QC parameters per filter and per quadrant. The definition of the parameters is explained on the QC twflat page. There had been only a very few events during the Hawaii detector life time when the QC1 parameters reached and exceeded the per-cent level.

Fig.1. Odd columns mean parameter upper left quadrant of the detector.
Fig.2. Odd columns mean parameter upper right quadrant of the detector.
Fig.5. Odd columns mean parameter lower left quadrant of the detector.
Fig.6. Odd columns mean parameter lower right quadrant of the detector.
Fig.3. Odd columns stdev parameter upper left quadrant of the detector.
Fig.4. Odd columns stdev parameter upper right quadrant of the detector.
Fig.7. Odd columns stdev parameter lower left quadrant of the detector.
Fig.8. Odd columns stdev parameter lower right quadrant of the detector.

This QC1 parameters are sensitive to changes in the linearity of odd and even columns separately. Find more information about ISAAC QC parameters derived from twilight flats here.

 


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up