[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
ISAAC trending system: HISTORY report
Last update: 2012-06-16T20:33:52 (UT)
same group: SW_Offset SW_Disp SW_RESPOW SW_ArcLamps SW_XCORR LW_Offset LW_Disp LW_ResPow   DISP(LAM) RESP(LAM)
close window history: 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011   2012   2013   HEALTH
  ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
  • 2007-04-03: migrated to trendPlotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 2.47252 ADU none   3 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, LR, SZ, argon lamp
2 QC1DB MEDIAN   ADU none   0 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, LR, J, argon lamp
2 xQC1DB MEDIAN 3.48567 ADU none   9 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, LR, J, xenon lamp
3 QC1DB MEDIAN   ADU none   0 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, LR, SH, argon lamp
3 xQC1DB MEDIAN   ADU none   0 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, LR, SH, xenon lamp
4 QC1DB MEDIAN   ADU none   0 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, LR, SK, argon lamp
4 xQC1DB MEDIAN   ADU none   0 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, LR, SK, xenon lamp
5 QC1DB MEDIAN   ADU none   0 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, MR, SH, argon and xenon lamp
6 QC1DB MEDIAN   ADU none   0 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, MR, J, argon and xenon lamp
7 QC1DB MEDIAN   ADU none   0 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, MR, SH, argon and xenon lamp
8 QC1DB MEDIAN 1.23331 ADU none   2 qc_dispco2 this | last_yr | all dispersion in Ang/pixel for SW, MR, SK, argon and xenon lamp
*Data sources: QC1DB: QC1 database; LOCAL: local text file
Plot 1
data source:isaac_arc
(QC1 database)
dataset:qc_dispco2
median:2.47252ADU
thresholds:none 
N_data plotted:3
[click on plot for closeup]
Plot 2
data source:isaac_arc
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_dispco2
median:no dataADU
thresholds:none 
N_data plotted:0
[click on plot for closeup]
Plot 3
data source:isaac_arc
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_dispco2
median:no dataADU
thresholds:none 
N_data plotted:0
[click on plot for closeup]
Plot 4
data source:isaac_arc
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_dispco2
median:no dataADU
thresholds:none 
N_data plotted:0
[click on plot for closeup]
Plot 5
data source:isaac_arc
(QC1 database)
dataset:qc_dispco2
median:no dataADU
thresholds:none 
N_data plotted:0
[click on plot for closeup]
Plot 6
data source:isaac_arc
(QC1 database)
dataset:qc_dispco2
median:no dataADU
thresholds:none 
N_data plotted:0
[click on plot for closeup]
Plot 7
data source:isaac_arc
(QC1 database)
dataset:qc_dispco2
median:no dataADU
thresholds:none 
N_data plotted:0
[click on plot for closeup]
Plot 8
data source:isaac_arc
(QC1 database)
dataset:qc_dispco2
median:1.23331ADU
thresholds:none 
N_data plotted:2
[click on plot for closeup]
This plot

This is the trending plot for the ISAAC arc lamp calibrations of the SW-arm

The QC parameter is the dispersion as derived from the wavelength solution of the pipeline recipe (HIERARCH ESO QC DISPC02) . The parameter is given in ang/pixel units.

These plots describe:
1. Dispersion for SW-arm, LR-grating, SZ-filter. Only Argon lamp used.Bb> 2. Dispersion for SW-arm, LR-grating, J-filter. Argon (red diamont) and Xenon (blue cross).
3. Dispersion for SW-arm, LR-grating, SH-filter. Argon (red diamont) and Xenon (blue cross).
4. Dispersion for SW-arm, LR-grating, SK-filter. Argon (red diamont) and Xenon (blue cross).

5. Dispersion for SW-arm, MR-grating, SZ-filter. Both Argon and Xenon lamps are on.
6. Dispersion for SW-arm, MR-grating, J-filter. Both Argon and Xenon lamps are on.
7. Dispersion for SW-arm, MR-grating, SH-filter. Both Argon and Xenon lamps are on.
8. Dispersion for SW-arm, MR-grating, SK-filter. Both Argon and Xenon lamps are on.

The color coding is: red for Argon alone lamp exposure, blue for Xenon alone lamp exposure and black for Argon+Xenon lamp exposure. For the LR grating there is for each lamp one dedicated exposure. For the MR grating there is one exposure showing the mixed spectrum of both lamps.

Find more information about ISAAC QC parameters derived from twilight flats here.

 


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up