HAWKI trending system: KPI report
HELP USERS-GUIDE MORE
Last update: 2024-07-27T16:31:36 (UT)
  | now: 2024-07-27T23:18:22 (UT) muc04 QC pipeline: hawki-2.4.12 (installed 2023-06-22)
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
HAWKI news:  
Report news:

scores&comments | history: all data plotted here | plot tutorial ... | contact | HC_docu...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   ADU none  5511 qc_ron23 all (full time range) Mean DARK ReadOut Noise, chip 4, DIT=2.0
2 QC1DB none   ADU none  5517 qc_ron23 all (full time range) Mean DARK ReadOut Noise, chip 3, DIT=2.0
3 QC1DB none   ADU none  4953 qc_ron23 all (full time range) Mean DARK ReadOut Noise, chip 4, DIT=300
4 QC1DB none   ADU none  4953 qc_ron23 all (full time range) Mean DARK ReadOut Noise, chip 3, DIT=300
5 QC1DB none   ADU none  5527 qc_ron23 all (full time range) Mean DARK ReadOut Noise, chip 1, DIT=2.0
6 QC1DB none   ADU none  5512 qc_ron23 all (full time range) Mean DARK ReadOut Noise, chip 2, DIT=2.0
7 QC1DB none   ADU none  4953 qc_ron23 all (full time range) Mean DARK ReadOut Noise, chip 1, DIT=300
8 QC1DB none   ADU none  4952 qc_ron23 all (full time range) Mean DARK ReadOut Noise, chip 2, DIT=300
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 5
data source:hawki_dark
(QC1 database)
dataset:qc_ron23
average:none
thresholds:none
N_data plotted:5527
(current) reference:9.68
[click plot for closeup]
Plot 6
data source:hawki_dark
(QC1 database)
dataset:qc_ron23
average:none
thresholds:none
N_data plotted:5512
(current) reference:8.9
[click plot for closeup]
Plot 2
data source:hawki_dark
(QC1 database)
dataset:qc_ron23
average:none
thresholds:none
N_data plotted:5517
(current) reference:8.11
[click plot for closeup]
Plot 1
data source:hawki_dark
(QC1 database)
dataset:qc_ron23
average:none
thresholds:none
N_data plotted:5511
(current) reference:8.24
[click plot for closeup]
Plot 7
data source:hawki_dark
(QC1 database)
dataset:qc_ron23
average:none
thresholds:none
N_data plotted:4953
(current) reference:6.05
[click plot for closeup]
Plot 8
data source:hawki_dark
(QC1 database)
dataset:qc_ron23
average:none
thresholds:none
N_data plotted:4952
(current) reference:5.4
[click plot for closeup]
Plot 4
data source:hawki_dark
(QC1 database)
dataset:qc_ron23
average:none
thresholds:none
N_data plotted:4953
(current) reference:5.48
[click plot for closeup]
Plot 3
data source:hawki_dark
(QC1 database)
dataset:qc_ron23
average:none
thresholds:none
N_data plotted:4953
(current) reference:4.66
[click plot for closeup]
This plot

This is intrument performance plot for the HAWKI detectors' ReadOut Noise [RON] of the master dark.
QC parameter is derived for each detector of the raw dark frames. Only the "NonDest" readout mode is monitored.

On 2016-11-19 new CASU pipeline was adopted (blue vertical line).

The reference value for each detector for monitore DET.DIT=2s and 300s is currently identical to the median of the measured values.

These plots describe:
Fig. 1. chip4: The QC parameter for DIT=2.0 for chip #4. Reference value: 8.245
Fig. 2. chip3: The QC parameter for DIT=2.0 for chip #3. Reference value: 8.11
Fig. 3. chip4: The QC parameter for DIT=300.0 for chip #4. Reference value: 4.66
Fig. 4. chip3: The QC parameter for DIT=300.0 for chip #3. Reference value: 5.48
Fig. 5. chip1: The QC parameter for DIT=2.0 for chip #1. Reference value: 9.68
Fig. 6. chip2: The QC parameter for DIT=2.0 for chip #2. Reference value: 8.9
Fig. 7. chip1: The QC parameter for DIT=300.0 for chip #1 Reference value: 6.05
Fig. 8. chip2: The QC parameter for DIT=300.0 for chip #2. Reference value: 5.4
 


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up