[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
FORS2 trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-21T17:08:45 (UT)
  | now: 2024-11-22T10:33:12 (UT) muc01 QC pipeline: fors-5.6.10 (installed 2024-04-19)
same group: lambda_c resolution nwave lambda_temp   EEV:lambda_c EEV:resolution EEV:nwave
close window history: 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH FULL
  ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 490 NONE 5%± 24.5 3 central_resol this | last_yr | all average resolution at center for chip 1
2 QC1DB MEDIAN 508 NONE 5%± 25.4 3 central_resol this | last_yr | all average resolution at center for chip 2
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:fors2_mos_wave
(QC1 database)
dataset:central_resol
median:490NONE
rel. thresholds: ±5%465.544328311...514.548994449NONE
N_data plotted:3
[click plot for closeup]
Plot 2
scores: not implemented
data source:fors2_mos_wave
(QC1 database)
dataset:central_resol
median:508NONE
rel. thresholds: ±5%482.319360348...533.089819332NONE
N_data plotted:3
[click plot for closeup]
This plot

From a wavelength calibrated MOS arc lamp exposure, the mean spectral resolution from all lines in catalog is computed. Each single spectral resolution is computed as the ratio between the arc lamp line wavelength and its FWHM. The values trended here are for the 300V grism with a slit width of 1.0" and the order separation filter GG435. Data have been acquired using the blue-sensitive EEV detector.

More information can be found on the plot tutorial page  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up