[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
AMBER trending system: FULL plot
Last update: 2011-08-12T18:29:55 (UT)
| now: 2024-07-17T09:04:40 (UT)
HELP USERS-GUIDE MORE
same group: IntVis_temp
[an error occurred while processing this directive]
DATE*: [?] 2018-09-10
no data | NLT
2018-09-11
no data | NLT
2018-09-12
no data | NLT
2018-09-13
no data | NLT
2018-09-14
no data | NLT
2018-09-15
no data | NLT
2018-09-16
no data | NLT
r...
Raw CAL displays:
no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files
P...
CAL product quality:
no CAL products no CAL products no CAL products no CAL products no CAL products no CAL products no CAL products
  no OPSLOG data  
Print: Information and research: News:
- png file  
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 LOCAL no none   NONE none   2132 bas12 n/a  
2 LOCAL no none   NONE none   2132 bas23 n/a  
3 LOCAL no none   NONE none   2132 bas31 n/a  
4 LOCAL no MEDIAN 14.38 NONE none   2132 temp n/a  
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
data source:local text file
parameter | dataset:bas12
average:none
thresholds:none
N_data:2132
[click on plot for closeup]
Plot 2
data source:local text file
parameter | dataset:bas23
average:none
thresholds:none
N_data:2132
[click on plot for closeup]
Plot 3
data source:local text file
parameter | dataset:bas31
average:none
thresholds:none
N_data:2132
[click on plot for closeup]
Plot 4
data source:local text file
parameter | dataset:temp
median:14.38NONE
thresholds:none 
N_data:2132
[click on plot for closeup]
This plot

The P2VM (Pixel to Visibility Matrix) is used to calibrate the science data. The pipeline product provides also some QC parameters which are used to monitor the Instrumental transfer function and the offset between the photometric beams.
In Low resolution JHK, the Instrumental Visibility is calculated across the full JHK spectrum (this plot) or in the individual bands (J, H and K). The band K,H,J Instrumental Visibilities are shown in the HC plots: K_P2VM_LJHK, H_P2VM_LJHK, J_P2VM_LJH.
The HC plot "with_temp" is a long range plot where the temperature inside the lab is also plotted. This could show some correlation etween internal Visibility and temperature (see also environment HC plots under Non Daily)  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up