[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
AMBER trending system: HISTORY report
HELP USERS-GUIDE MORE
Last update: 2018-09-01T06:12:15 (UT)
same group: flux_throughput_LR_AT flux_throughput_HR_AT flux_throughput_LR_UT flux_throughput_HR_UT
close window history: 2011 2012 2013 2014 2015 2016 2017 2018   HEALTH FULL
  ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   ADU/s/px none  537 MSPECTRUM_1 this | last_yr | all LRK beam1_AT1
1 QC1DB none   ADU/s/px none  132 MSPECTRUM_2 this | last_yr | all LRK beam2_AT1
1 QC1DB none   ADU/s/px none  25 MSPECTRUM_3 this | last_yr | all LRK beam3_AT1
2 QC1DB none   ADU/s/px none  0 MSPECTRUM_1 this | last_yr | all LRK beam1_AT2
2 QC1DB none   ADU/s/px none  65 MSPECTRUM_2 this | last_yr | all LRK beam2_AT2
2 QC1DB none   ADU/s/px none  326 MSPECTRUM_3 this | last_yr | all LRK beam3_AT2
3 QC1DB none   ADU/s/px none  172 MSPECTRUM_1 this | last_yr | all LRK beam1_AT3
3 QC1DB none   ADU/s/px none  61 MSPECTRUM_2 this | last_yr | all LRK beam2_AT3
3 QC1DB none   ADU/s/px none  323 MSPECTRUM_3 this | last_yr | all LRK beam3_AT3
4 QC1DB none   ADU/s/px none  36 MSPECTRUM_1 this | last_yr | all LRK beam1_AT4
4 QC1DB none   ADU/s/px none  487 MSPECTRUM_2 this | last_yr | all LRK beam2_AT4
4 QC1DB none   ADU/s/px none  71 MSPECTRUM_3 this | last_yr | all LRK beam3_AT4
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
data source:amber_performances
(QC1 database)
dataset:
(numbers below apply to this dataset)
MSPECTRUM_1
average:none
thresholds:none
N_data plotted:537
[click plot for closeup]
Plot 2
data source:amber_performances
(QC1 database)
dataset:
(numbers below apply to this dataset)
MSPECTRUM_1
average:none
thresholds:none
N_data plotted:0
[click plot for closeup]
Plot 3
data source:amber_performances
(QC1 database)
dataset:
(numbers below apply to this dataset)
MSPECTRUM_1
average:none
thresholds:none
N_data plotted:172
[click plot for closeup]
Plot 4
data source:amber_performances
(QC1 database)
dataset:
(numbers below apply to this dataset)
MSPECTRUM_1
average:none
thresholds:none
N_data plotted:36
[click plot for closeup]
This plot

One of the IOT project is to monitor the throughput of the AMBER instrument.

GROUP "flux_magnitude":
The pipeline calculates a QC parameter which corresponds to the total flux in the central 80% of the spectrum (J H or K) for the different photometric channels P1 P2 P3. These values are given in e-
They are afterwards corrected in ADU/s/px (gain used: 4.7)
This is not corrected for the magnitude and the transmission of the VLTI.

The AMBER flux is shown as a function of the K/H magnitude (extracted from the calibrator databasexi or from SIMBAD) in this group of plots.
There are several plots:
-- flux_mag_AT/UT: for the ATs (groups 1-2) and UTs (groups 3-4): we plot flux=f(mag) for LRK, MK (2.1 and 2.3), MH, HK (2.172, 2.288)
-- Last groups: flux_mag_tel: we show on the same plot the data for the ATs and UTs for the 3 beams for LK, MK (2.1) and HK (2.172)

GROUP "flux_magnitude_FNT":
A corrected AMBER flux in the interferometric channels (per ADU/s/pixel) is calculated by an additional script.
This is not corrected for the magnitude of the object and for the transmission of the VLTI.

The AMBER flux is shown as a function of the K/H magnitude (extracted from SIMBAD) in this group of plots.
There are several plots:
-- flux_mag_AT/UT: for the ATs (groups 1-2) and UTs (groups 3-4): we plot flux=f(mag) for LRK, MK (2.1 and 2.3), MH, HK (2.172, 2.288)
-- Last groups: flux_mag_tel: we show on the same plot the data for the ATs and UTs for the 3 beams for LK, MK (2.1) and HK (2.172)

GROUP "Throughput":
The pipeline calculates a QC parameter which corresponds to the total flux in the central 80% of the spectrum (J H or K) for the different photometric channels P1 P2 P3. These values are given in e-
They are afterwards corrected in ADU/s/px (gain used: 4.7) and for the magnitude of the object (from SIMBAD or the calibrator data base)
This is not corrected for the transmission of the VLTI.
The AMBER corrected flux is trended in time for each telescope (AT1 to AT4 and UT1 to UT4) for the 2 settings LR and HR 2.172


Additional parameters (such as for ex. transmission and magnitude) are available in the amber_performances qc1database
 


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up