[an error occurred while processing this directive]
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
AMBER trending system: HISTORY plot
Last update: 2011-08-13T18:36:11 (UT)
close window history: 2006   2007   2008   2009 2010 2011   HEALTH
  ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 LOCAL MEDIAN 16.28 NONE none   34 temp_lab n/a temp in the lab (CAU)
1 LOCAL MEDIAN 12.88 NONE none   25510 temp_dimm n/a DIMM temp
2 LOCAL MEDIAN 12.0 NONE none   25510 temp_dimm n/a DIMM humidity
3 LOCAL none   NONE none   34 bas12 n/a VIS12
4 LOCAL none   NONE none   34 bas23 n/a VIS23
5 LOCAL none   NONE none   34 bas31 n/a VIS31
*Data sources: QC1DB: QC1 database; LOCAL: local text file
Plot 1
data source:local text file
parameter | dataset:
(numbers applicable to )
temp_lab
median:16.28NONE
thresholds:none 
N_data:34
[click on plot for closeup]
Plot 2
data source:local text file
parameter | dataset:temp_dimm
median:12.0NONE
thresholds:none 
N_data:25510
[click on plot for closeup]
Plot 3
data source:local text file
parameter | dataset:bas12
average:none
thresholds:none
N_data:34
[click on plot for closeup]
Plot 4
data source:local text file
parameter | dataset:bas23
average:none
thresholds:none
N_data:34
[click on plot for closeup]
Plot 5
data source:local text file
parameter | dataset:bas31
average:none
thresholds:none
N_data:34
[click on plot for closeup]
This plot

The P2VM (Pixel to Visibility Matrix) is used to calibrate the science data. The pipeline product provides also some QC parameters which are used to monitor the Instrumental transfer function and the offset between the photometric beams.
In Low resolution JHK, the Instrumental Visibility is calculated across the full JHK spectrum (this plot) or in the individual bands (J, H and K). The band K,H,J Instrumental Visibilities are shown in the HC plots: K_P2VM_LJHK, H_P2VM_LJHK, J_P2VM_LJH.
The HC plot "with_temp" is a long range plot where the temperature inside the lab is also plotted. This could show some correlation etween internal Visibility and temperature (see also environment HC plots under Non Daily)  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up