GIRAFFE ARGUS DFOS_OPS calibration cascade

DFOS_OPS | CALCHECKER | CALSELECTOR (current) || select other instrument: OCA
OCA rule set:GIRAFFE.RLS
Type of rule set:DFOS_OPS (current operational rules for QC; no versioning)
Sub-cascades: ALL       MEDUSA | IFU | ARGUS | HealthChecks
General comment:For processing, NFLATs are used. STD and FFLATs are added.

Mouse over ...
- a RAW_TYPE to see the classification rule (M marks a multiple definition)
- a grouping rule to see the complete grouping rule
- a matching rule (e.g. '1,1') to see the product matching rule.
Product tags etc. might be cut off, in that case mouse over the cell to see the full entry.

bottom | right left     
RAW_TYPEACQ BIAS DARK FFLAT NFLT WAVE STD_ARG SCI_ARG M
DO_CLASSACQ_FACB BIAS DARK FIBER_FLAT NASMYTH_FLAT ARC_SPECTRUM STD_ARG SCI_OZPOZ_ARG,
SCI_SIMCAL_ARG
CATGACQUISITION CALIB CALIB CALIB CALIB CALIB CALIB SCIENCE
Grouping rule single TPL_A TPL_A TPL_A TPL_A single single single
Recipe none gimasterbias gimasterdark gimasterflat gimasterflat giwavecalibration gistandard giscience
Index12345678

Calibration cascade:
static mcalibs:master calibs:
1 GRATING_DATA       1,1 1,1 1,1 1,1 1,1
2 SLIT_GEOMETRY_SETUP       1,1 1,1 1,1 1,1 1,1
3 LINE_MASK               0,1
5 ATMOSPHERIC_EXTINCTI...             1,1 0,1 MASSOC
6 FLUX_STANDARDS             1,1 0,1 MASSOC
7 LINE_CATALOG           1,1    
8 REFERENCE_DISP_SOLUT...           1,1    
    9 MASTER_BIAS 1,1 1,1 1,1 1,1 1,1 1,1
      10 MASTER_DARK         0,0
        11 FF_EXTERRORS       0,1 MASSOC
        12 FF_EXTSPECTRA       0,1 MASSOC
        13 FF_LOCCENTROID   1,1   0,1 MASSOC
        14 FF_LOCWIDTH   1,1   0,1 MASSOC
          15 NF_EXTERRORS   1,1 1,1
          16 NF_EXTSPECTRA   1,1 1,1
          17 NF_LOCCENTROID   1,1 1,1
          18 NF_LOCWIDTH   1,1 1,1
            19 ARC_RBNSPECTRA   0,1 MASSOC
            20 DISPERSION_SOLUTION 1,1 1,1
              21 INSTRUMENT_RESPONSE 0,1 MASSOC
              22 STD_RBNSPECTRA 0,1 MASSOC
              23 STD_RCSPECTRA 0,1 MASSOC
                24 SCIENCE_RBNSPECTRA

Comments:
      HC calibs; used for cascade with old CCD normal fibre flats (used for MEDUSA reduction, otherwise MASSOC) nasmyth flats with better illumin. (used for IFU+ARGUS reduction, otherwise MASSOC)      

Analysis (technical consistency checks):
products* (CALIB only) n/a OK OK OK OK OK OK n/a
mcalibs** n/a n/a OK OK OK OK OK OK
powered by QC [createCalibMap v2.1] last update: 2018-06-11T09:43:51
*products: does raw_type have a product? (CALIB only)
**mcalibs: are all required mcalibs, per raw_type, somewhere listed as products?