UVES ECH_SLIC_RED CALSELECTOR calibration cascade

DFOS_OPS | CALCHECKER | CALSELECTOR (current) || select other instrument: OCA
OCA rule set:UVES_raw2master.2008-01-18.RLS | other versions
Start-date:2008-01-18
Type of rule set:CALSELECTOR (raw2master type of association; versioning supported)
Sub-cascades: ALL       ECH_BLUE | ECH_SLIC_BLUE | ECH_RED | ECH_ABS_RED | ECH_SLIC_RED | ECH_SLICABS_RED | MOS_RED
General comment:Echelle mode with image slicers, red arm; identical to "ECH_RED"; except for STD and SCI

Mouse over ...
- a RAW_TYPE to see the classification rule (M marks a multiple definition)
- a grouping rule to see the complete grouping rule
- a matching rule (e.g. '1,1') to see the product matching rule.
Product tags etc. might be cut off, in that case mouse over the cell to see the full entry.
EXPOSE: marks those non-SCIENCE RAW_TYPEs which can be exceptionally exposed to CALSELECTOR.

Time match rules:
GT: no validity for this static mcalib defined
T: no validity for this mcalib defined
< PREVIOUS time match
||-7.0/+7.0  calib_plan validity (best mjd_obs time difference) and extended validity defined
(-2.0/+2.0)  calib_plan validity not defined, only extended validity (maximum mjd_obs time difference)
[-2.0/+2.0]  calib_plan validity defined, but no extended validity

bottom | right left     
RAW_TYPEBIAS_RED FMTCHK_ECH_RED ORDERDEF_ECH_RED EFLAT_ECH_RED WAVE_ECH_RED STD_ECH_RED SCI_SLIC_ECH_RED ACQ_ECH
DO_CLASSBIAS_RED ARC_LAMP_FORM_RED ORDER_FLAT_RED FLAT_RED ARC_LAMP_RED STANDARD_RED SCI_SLICER_RED ACQ_ECH
CATGCALIB CALIB CALIB CALIB CALIB CALIB   EXPOSE SCIENCE ACQUISITION
Grouping rule TPL_A single single TPL_A single single single single
Recipe uves_cal_mbias uves_cal_predict uves_cal_orderpos uves_cal_mflat uves_cal_wavecal uves_cal_response uves_obs_scired none
Index12345678

Calibration cascade:
static mcalibs:master calibs:
1 LINE_REFER_TABLE   1,1<     1,1<      
3 MASTER_FORM_REDL   0,1<            
4 MASTER_FORM_REDU   0,1<            
6 EXTCOEFF_TABLE           1,1< 1,1<  
8 MASTER_RESPONSE_REDL             0,1<  
9 MASTER_RESPONSE_REDU             0,1<  
10 FLUX_STD_TABLE           1,1<    
11 RESP_FIT_POINTS_CATALOG           1,1<    
15 LINE_INTMON_TABLE         0,1<      
  16 MASTER_BIAS_REDL     0,1 ||-7.0/+7.0   1,1 ||-7.0/+7.0 1,1 ||-7.0/+7.0  
  17 MASTER_BIAS_REDU     0,1 ||-7.0/+7.0   1,1 ||-7.0/+7.0 1,1 ||-7.0/+7.0  
    18 LINE_GUESS_TAB_REDL     1,1      
    19 LINE_GUESS_TAB_REDU     1,1      
    20 ORDER_GUESS_TAB_REDL 1,1 ||-3.0/+3.0          
    21 ORDER_GUESS_TAB_REDU 1,1          
      22 ORDER_TABLE_REDL 1,1 1,1 1,1 1,1  
      23 ORDER_TABLE_REDU 1,1 1,1 1,1 1,1  
        24 MASTER_FLAT_REDL   1,1 1,1  
        25 MASTER_FLAT_REDU   1,1 1,1  
          26 LINE_TABLE_REDL 1,1 1,1  
          27 LINE_TABLE_REDU 1,1 1,1  
            28 INSTR_RESPONSE_FINE_REDL 0,1  
            29 INSTR_RESPONSE_FINE_REDU 0,1  
              30 RED_SCI_SLICER_RED  

Comments:
            associated to SCIENCE irrespective of binning and slit three SLICERs; different red MASTER_RESPONSE_CURVES for Upper chip before and after 54997 corresponding to 2009-06-15 (CCD change)  

Analysis (technical consistency checks):
raw_type* (CALIB only) OK OK OK OK OK OK n/a n/a
mcalibs** n/a OK OK OK OK OK OK n/a
powered by QC [createCalibMap v2.1.1] last update: 2020-06-10T10:54:54
*raw_type: is raw_type used in cascade? (CALIB only)
**mcalibs: are all required mcalibs, per raw_type, somewhere listed as products?
top