UVES ECH_ABS_RED CALSELECTOR calibration cascade

DFOS_OPS | CALCHECKER | CALSELECTOR (current) || select other instrument: OCA
OCA rule set:UVES_raw2master.2007-04-01.RLS | other versions
Start-date:2007-04-01
Type of rule set:CALSELECTOR (raw2master type of association; versioning supported)
Sub-cascades: ALL       ECH_BLUE | ECH_SLIC_BLUE | ECH_RED | ECH_ABS_RED | ECH_SLIC_RED | ECH_SLICABS_RED | MOS_RED
General comment:

Mouse over ...
- a RAW_TYPE to see the classification rule (M marks a multiple definition)
- a grouping rule to see the complete grouping rule
- a matching rule (e.g. '1,1') to see the product matching rule.
Product tags etc. might be cut off, in that case mouse over the cell to see the full entry.
EXPOSE: marks those non-SCIENCE RAW_TYPEs which can be exceptionally exposed to CALSELECTOR.

Time match rules:
GT: no validity for this static mcalib defined
T: no validity for this mcalib defined
< PREVIOUS time match
||-7.0/+7.0  calib_plan validity (best mjd_obs time difference) and extended validity defined
(-2.0/+2.0)  calib_plan validity not defined, only extended validity (maximum mjd_obs time difference)
[-2.0/+2.0]  calib_plan validity defined, but no extended validity

bottom | right left     
RAW_TYPEBIAS_RED FMTCHK_ECH_RED ORDERDEF_ECH_RED EFLAT_ECH_RED IFLAT_ECH_RED WAVE_ECH_RED STD_ECH_RED ACQ_ECH
DO_CLASSBIAS_RED ARC_LAMP_FORM_RED ORDER_FLAT_RED FLAT_RED IFLAT_RED ARC_LAMP_RED STANDARD_RED ACQ_ECH
CATGCALIB CALIB CALIB CALIB CALIB CALIB CALIB   EXPOSE ACQUISITION
Grouping rule TPL_A single single TPL_A TPL_A single single single
Recipe uves_cal_mbias uves_cal_predict uves_cal_orderpos uves_cal_mflat uves_cal_mflat uves_cal_wavecal uves_cal_response none
Index12345678

Calibration cascade:
static mcalibs:master calibs:
1 LINE_REFER_TABLE   1,1<       1,1<    
3 MASTER_FORM_REDL   0,1<            
4 MASTER_FORM_REDU   0,1<            
6 EXTCOEFF_TABLE             1,1<  
10 FLUX_STD_TABLE             1,1<  
11 RESP_FIT_POINTS_CATALOG             1,1<  
15 LINE_INTMON_TABLE           0,1<    
  16 MASTER_BIAS_REDL     0,1 ||-7.0/+7.0 0,1 ||-7.0/+7.0   1,1 ||-7.0/+7.0  
  17 MASTER_BIAS_REDU     0,1 ||-7.0/+7.0 0,1 ||-7.0/+7.0   1,1 ||-7.0/+7.0  
    18 LINE_GUESS_TAB_REDL       1,1    
    19 LINE_GUESS_TAB_REDU       1,1    
    20 ORDER_GUESS_TAB_REDL 1,1 ||-3.0/+3.0          
    21 ORDER_GUESS_TAB_REDU 1,1          
      22 ORDER_TABLE_REDL 1,1 1,1 1,1 1,1  
      23 ORDER_TABLE_REDU 1,1 1,1 1,1 1,1  
        24 MASTER_FLAT_REDL     1,1  
        25 MASTER_FLAT_REDU     1,1  
          26 MASTER_IFLAT_REDL      
          27 MASTER_IFLAT_REDU      
            28 LINE_TABLE_REDL 1,1  
            29 LINE_TABLE_REDU 1,1  
              30 INSTR_RESPONSE_FINE_REDL  
              31 INSTR_RESPONSE_FINE_REDU  

Comments:
          Flats with absorption cell, for the red arm only      

Analysis (technical consistency checks):
raw_type* (CALIB only) OK OK OK OK OK OK OK n/a
mcalibs** n/a OK OK OK OK OK OK n/a
powered by QC [createCalibMap v2.1.1] last update: 2020-06-10T10:41:38
*raw_type: is raw_type used in cascade? (CALIB only)
**mcalibs: are all required mcalibs, per raw_type, somewhere listed as products?
top