FORS2 SCI_PMOS CALSELECTOR calibration cascade

DFOS_OPS | CALCHECKER | CALSELECTOR (current) || select other instrument: OCA
OCA rule set:FORS2_raw2raw.2008-04-01.RLS
Start-date:2008-04-01
Type of rule set:CALSELECTOR (gencalibs defined but no HC calibs; raw2raw type of association)
Sub-cascades: ALL       SCI_IMG | SCI_LSS | SCI_MOS | SCI_MXU | SCI_IPOL | SCI_PMOS | SCI_HIT | SCI_HIT_S | SCI_HIT_MS
General comment:polarimetric standards are taken with MOS #10 slit on chip C1 only

Mouse over ...
- a RAW_TYPE to check out the classification rule (M marks a multiple definition)
- a grouping rule to see the complete grouping rule
- a matching rule (e.g. '1,1') to see the product matching rule. '3,-1' means: all from same template, but at least 3.
Product tags etc. might be cut off, in that case mouse over the cell to see the full entry.
GT: mandatory validity (time match rule) for this gencalib is missing
<   : correct time match rule for gencalib (PREVIOUS); ?: wrong time match rule
T: mandatory validity (time match rule) for this match is missing
|| 7.0 : correct validity (time match) for this match

bottom | right left     
RAW_TYPEACQ_PMOS_SKY ACQ_PMOS_SLIT BIAS LAMP_PMOS M STD_PMOS_C1 STD_PMOS_C2 SCI_PMOS_C1 SCI_PMOS_C2
DO_CLASSACQUISIT_PMOS_SKY ACQUISIT_PMOS_SLIT BIAS LAMP_PMOS,
SCREEN_FLAT_PMOS
STANDARD_PMOS STANDARD_PMOS SCIENCE_PMOS SCIENCE_PMOS
CATGACQUISITION ACQUISITION CALIB CALIB CALIB CALIB SCIENCE SCIENCE
Grouping rule single single TPL.START TPL.START TPL.START TPL.START TPL.START TPL.START
Index12345678

Calibration cascade:
static calibs:calib matches:
1 GRISM_TABLE       1,1< 1,1< 1,1< 1,1< 1,1<
2 MASTER_LINECAT       1,1<        
3 MASTER_DISTORTION_TA...       1,1< 1,1< 1,1<    
6 RETARDER_WAVEPLATE_C...         1,1< 0,1< 1,1< 1,1<
14 STD_PMOS_TABLE         1,1<      
  15 ACQ_PMOS_SKY_RASSOC           0,-1 || 0.5 0,-1 || 0.5
    16 ACQ_PMOS_SLIT_RASSOC...         0,-1 || 0.5 0,-1 || 0.5
      17 BIAS 5,-1 || 10 5,-1 || 10 5,-1 || 10 5,-1 || 10 5,-1 || 10
        18 LAMP_PMOS 5,-1 || 8 5,-1 || 8 5,-1 || 8 5,-1 || 8
          19 STD_PMOS_C1   0,10 || 7  
            20 STD_PMOS_C2   0,10 || 7

Comments:
        arc and flat calibrations products of the polarimetric standard star acquired on chip 1 placeholder for the raw frames of chip 2 polarimetric standard in chip 1 required  

Analysis (technical consistency checks):
raw_type* (CALIB only) n/a n/a OK OK OK OK n/a n/a
powered by QC [createCalibMap v1.3.1] last update: 2013-05-24T11:39:10
*raw_type: is raw_type used in cascade? (CALIB only)

top